Comparison of different label-free imaging high-throughput biosensing systems for aptamer binding measurements using thrombin aptamers

被引:8
作者
Rath, Christin [1 ,2 ,3 ,5 ]
Burger, Juergen [1 ,5 ]
Norval, Leo [1 ]
Kraemer, Stefan Daniel [1 ,2 ]
Gensch, Nicole [4 ]
van der Kooi, Alexander [6 ]
Reinemann, Christine [7 ,10 ]
O'Sullivan, Ciara [8 ,9 ]
Svobodova, Marketa [8 ]
Roth, Guenter [1 ,2 ,3 ,5 ]
机构
[1] Univ Freiburg, Ctr Biol Syst Anal, Lab Microarray Copying, ZBSA, Habsburgerstr 49, D-79104 Freiburg, Germany
[2] Univ Freiburg, Fac Biol, Schanzlestr 1, D-79104 Freiburg, Germany
[3] Univ Freiburg, Ctr Biol Signaling Studies BIOSS, D-79104 Freiburg, Germany
[4] Univ Freiburg, Ctr Biol Signaling Studies BIOSS, Core Facil Signalling Factory, D-79104 Freiburg, Germany
[5] BioCopy GmbH, D-79110 Freiburg, Germany
[6] IBIS Technol Bv, NL-7521 PR Enschede, Netherlands
[7] Helmholtz Ctr Environm Res GmbH UFZ, Permoserstr 15, D-04318 Leipzig, Germany
[8] Univ Rovira & Virgili, Dept Engn Quim, E-43007 Tarragona, Spain
[9] Inst Catalana Recerca & Estudis Avancats, Barcelona 08010, Spain
[10] Aptamer Grp Ltd, Bio Ctr, Innovat Way, York YO10 5NY, N Yorkshire, England
关键词
Thrombin aptamer; Label-free; Reflecto-interferometry; BioLayer interferometry; Surface plasmon resonance; MicroScale thermophoresis; KINETICS; RECOGNITION; ADSORPTION; FIBRINOGEN; AFFINITY; PCR;
D O I
10.1016/j.ab.2019.05.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To enable the analysis of several hundreds to thousands of interactions in parallel, high-throughput systems were developed. We used established thrombin aptamer assays to compare three such high-throughput imaging systems as well as analysis software and user influence. In addition to our own iRIf-system, we applied bscreen and IBIS-MX96. As non-imaging reference systems we used Octet-RED96, Biacore3000, and Monolith-NT.115. In this study we measured 1378 data points. Our results show that all systems are suitable for analyzing binding kinetics, but the kinetic constants as well as the ranking of the selected aptamers depend significantly on the applied system and user. We provide an insight into the signal generation principles, the systems and the results generated for thrombin aptamers. It should contribute to the awareness that binding constants cannot be determined as easily as other constants. Since many parameters like surface chemistry, biosensor type and buffer composition may change binding behavior, the experimenter should be aware that a system and assay dependent K-D is determined. Frequently, certain conditions that are best suited for a given biosensing system cannot be transferred to other systems. Therefore, we strongly recommend using at least two different systems in parallel to achieve meaningful results.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Label-free aptamer-based sensors for L-argininamide by using nucleic acid minor groove binding dyes
    Zhu, Zece
    Yang, Chuluo
    Zhou, Xiang
    Qin, Jingui
    CHEMICAL COMMUNICATIONS, 2011, 47 (11) : 3192 - 3194
  • [42] Label-free and high-throughput removal of residual undifferentiated iPSCs from their differentiated progenitor cells by inertial microfluidic cell sorter
    Tan Dai Nguyen
    Chooi, Wai Hon
    Chen, Jiahui
    Roxby, Daniel Ninio
    Yao, Jerome Tan Zu
    Jeon, Hyungkook
    Ng, Shi Yan
    Chew, Sing Yian
    Han, Jongyoon
    TISSUE ENGINEERING PART A, 2022, 28 : 168 - 168
  • [43] Label-free high-throughput and real-time detections of protein interactions by oblique-incidence reflectivity difference method
    HE LiPing
    LIU Shuang
    DAI JunBeijing National Laboratory for Condensed Matter Physics
    Lü HuiBin
    JIN KuiJuan
    YANG GuoZhen
    Science China(Physics,Mechanics & Astronomy), 2014, (04) : 615 - 618
  • [44] Label-free high-throughput and real-time detections of protein interactions by oblique-incidence reflectivity difference method
    He LiPing
    Liu Shuang
    Dai Jun
    Lu HuiBin
    Jin KuiJuan
    Yang GuoZhen
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2014, 57 (04) : 615 - 618
  • [45] Label-free high-throughput and real-time detections of protein interactions by oblique-incidence reflectivity difference method
    LiPing He
    Shuang Liu
    Jun Dai
    HuiBin Lü
    KuiJuan Jin
    GuoZhen Yang
    Science China Physics, Mechanics and Astronomy, 2014, 57 : 615 - 618
  • [46] High spatial resolution label-free detection of antigen-antibody binding on patterned surface by imaging ellipsometry
    Chang, Meng-Jie
    Pang, Chao-Ran
    Liu, Jun
    Bai, Hua
    Deng, Jun
    Xu, Zhu-Guo
    Zhang, Hao-Li
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2011, 360 (02) : 826 - 833
  • [47] Optimal Parameter Configuration of a Microfluidic Chip for High-Throughput, Label-Free Circulating Tumor Cell Separation and Enrichment Based on Inertial Focusing
    Sun, Xiaoyi
    Ma, Yuqi
    Lu, Chunyang
    Cai, Ziwei
    Han, Jintao
    Wang, Zhigang
    Yang, Gen
    DIAGNOSTICS, 2023, 13 (23)
  • [48] Simultaneous, Label-Free and High-throughput SERS Detection of Multiple Pesticides on Ag@Three-Dimensional Silica Photonic Microsphere Array
    Xu, Ruimin
    Dai, Shijie
    Dou, Menghua
    Yang, Jing
    Wang, Xiu
    Liu, Xiaomeng
    Wei, Chenhong
    Li, Qianjin
    Li, Jianlin
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2023, 71 (06) : 3050 - 3059
  • [49] Dependence of cancer cell adhesion kinetics on integrin ligand surface density measured by a high-throughput label-free resonant waveguide grating biosensor
    Orgovan, Norbert
    Peter, Beatrix
    Boesze, Szilvia
    Ramsden, Jeremy J.
    Szabo, Balint
    Horvath, Robert
    SCIENTIFIC REPORTS, 2014, 4
  • [50] Label-Free Imaging of Single Proteins and Binding Kinetics Using Total Internal Reflection-Based Evanescent Scattering Microscopy
    Zhang, Pengfei
    Wang, Rui
    Wan, Zijian
    Zhou, Xinyu
    Ma, Guangzhong
    Kolay, Jayeeta
    Jiang, Jiapei
    Wang, Shaopeng
    ANALYTICAL CHEMISTRY, 2022, 94 (30) : 10781 - 10787