Comparison of different label-free imaging high-throughput biosensing systems for aptamer binding measurements using thrombin aptamers

被引:8
作者
Rath, Christin [1 ,2 ,3 ,5 ]
Burger, Juergen [1 ,5 ]
Norval, Leo [1 ]
Kraemer, Stefan Daniel [1 ,2 ]
Gensch, Nicole [4 ]
van der Kooi, Alexander [6 ]
Reinemann, Christine [7 ,10 ]
O'Sullivan, Ciara [8 ,9 ]
Svobodova, Marketa [8 ]
Roth, Guenter [1 ,2 ,3 ,5 ]
机构
[1] Univ Freiburg, Ctr Biol Syst Anal, Lab Microarray Copying, ZBSA, Habsburgerstr 49, D-79104 Freiburg, Germany
[2] Univ Freiburg, Fac Biol, Schanzlestr 1, D-79104 Freiburg, Germany
[3] Univ Freiburg, Ctr Biol Signaling Studies BIOSS, D-79104 Freiburg, Germany
[4] Univ Freiburg, Ctr Biol Signaling Studies BIOSS, Core Facil Signalling Factory, D-79104 Freiburg, Germany
[5] BioCopy GmbH, D-79110 Freiburg, Germany
[6] IBIS Technol Bv, NL-7521 PR Enschede, Netherlands
[7] Helmholtz Ctr Environm Res GmbH UFZ, Permoserstr 15, D-04318 Leipzig, Germany
[8] Univ Rovira & Virgili, Dept Engn Quim, E-43007 Tarragona, Spain
[9] Inst Catalana Recerca & Estudis Avancats, Barcelona 08010, Spain
[10] Aptamer Grp Ltd, Bio Ctr, Innovat Way, York YO10 5NY, N Yorkshire, England
关键词
Thrombin aptamer; Label-free; Reflecto-interferometry; BioLayer interferometry; Surface plasmon resonance; MicroScale thermophoresis; KINETICS; RECOGNITION; ADSORPTION; FIBRINOGEN; AFFINITY; PCR;
D O I
10.1016/j.ab.2019.05.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To enable the analysis of several hundreds to thousands of interactions in parallel, high-throughput systems were developed. We used established thrombin aptamer assays to compare three such high-throughput imaging systems as well as analysis software and user influence. In addition to our own iRIf-system, we applied bscreen and IBIS-MX96. As non-imaging reference systems we used Octet-RED96, Biacore3000, and Monolith-NT.115. In this study we measured 1378 data points. Our results show that all systems are suitable for analyzing binding kinetics, but the kinetic constants as well as the ranking of the selected aptamers depend significantly on the applied system and user. We provide an insight into the signal generation principles, the systems and the results generated for thrombin aptamers. It should contribute to the awareness that binding constants cannot be determined as easily as other constants. Since many parameters like surface chemistry, biosensor type and buffer composition may change binding behavior, the experimenter should be aware that a system and assay dependent K-D is determined. Frequently, certain conditions that are best suited for a given biosensing system cannot be transferred to other systems. Therefore, we strongly recommend using at least two different systems in parallel to achieve meaningful results.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Label-free reading of microarray-based proteins with high throughput surface plasmon resonance imaging
    Huang, Haowen
    Chen, Yi
    BIOSENSORS & BIOELECTRONICS, 2006, 22 (05) : 644 - 648
  • [32] Ultra-Sensitive and Label-Free Probing of Binding Affinity Using Recognition Imaging
    Oh, Yoo Jin
    Koehler, Melanie
    Lee, Yoonhee
    Mishra, Sourav
    Park, Joon Won
    Hinterdorfer, Peter
    NANO LETTERS, 2019, 19 (01) : 612 - 617
  • [33] Novel label-free and high-throughput microchip electrophoresis platform for multiplex antibiotic residues detection based on aptamer probes and target catalyzed hairpin assembly for signal amplification
    Wang, Ye
    Gan, Ning
    Zhou, You
    Li, Tianhua
    Hu, Futao
    Cao, Yuting
    Chen, Yinji
    BIOSENSORS & BIOELECTRONICS, 2017, 97 : 100 - 106
  • [34] Single-Step Selection of Bivalent Aptamers Validated by Comparison with SELEX Using High-Throughput Sequencing
    Wilson, Robert
    Bourne, Christian
    Chaudhuri, Roy R.
    Gregory, Richard
    Kenny, John
    Cossins, Andrew
    PLOS ONE, 2014, 9 (06):
  • [35] Interrogation of phosphor-specific interaction on a high-throughput label-free optical biosensor system-Epic® system
    Wu, Meng
    Long, Shunyou
    Frutos, Anthony G.
    Eichelberger, Maryna
    Li, Min
    Fang, Ye
    JOURNAL OF RECEPTORS AND SIGNAL TRANSDUCTION, 2009, 29 (3-4) : 202 - 210
  • [36] Rapid high-throughput compatible label-free virus particle quantification method based on time-resolved luminescence
    Kopra, Kari
    Hassan, Nazia
    Vuorinen, Emmiliisa
    Valtonen, Salla
    Mahran, Randa
    Habib, Huda
    Jalkanen, Pinja
    Susi, Petri
    Hytonen, Vesa
    Hankaniemi, Minna
    Yla-Herttuala, Seppo
    Kakkola, Laura
    Peurla, Markus
    Harma, Harri
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (15) : 4509 - 4518
  • [37] Applying flow cytometry to identify the modes of action of membrane-active peptides in a label-free and high-throughput fashion
    Wichmann, Nanna
    Lund, Philip M.
    Hansen, Morten B.
    Hjorringgaard, Claudia U.
    Larsen, Jannik B.
    Kristensen, Kasper
    Andresen, Thomas L.
    Simonsen, Jens B.
    BIOCHIMICA ET BIOPHYSICA ACTA-BIOMEMBRANES, 2022, 1864 (02):
  • [38] Rapid high-throughput compatible label-free virus particle quantification method based on time-resolved luminescence
    Kari Kopra
    Nazia Hassan
    Emmiliisa Vuorinen
    Salla Valtonen
    Randa Mahran
    Huda Habib
    Pinja Jalkanen
    Petri Susi
    Vesa Hytönen
    Minna Hankaniemi
    Seppo Ylä-Herttuala
    Laura Kakkola
    Markus Peurla
    Harri Härmä
    Analytical and Bioanalytical Chemistry, 2022, 414 : 4509 - 4518
  • [39] Application of High-Throughput Screening Raman Spectroscopy (HTS-RS) for Label-Free Identification and Molecular Characterization of Pollen
    Mondol, Abdullah S.
    Patel, Milind D.
    Rueger, Jan
    Stiebing, Clara
    Kleiber, Andreas
    Henkel, Thomas
    Popp, Jurgen
    Schie, Iwan W.
    SENSORS, 2019, 19 (20)
  • [40] Label-free and reagent-less protein biosensing using aptamer-modified extended-gate field-effect transistors
    Goda, Tatsuro
    Miyahara, Yuji
    BIOSENSORS & BIOELECTRONICS, 2013, 45 : 89 - 94