Comparison of different label-free imaging high-throughput biosensing systems for aptamer binding measurements using thrombin aptamers

被引:8
作者
Rath, Christin [1 ,2 ,3 ,5 ]
Burger, Juergen [1 ,5 ]
Norval, Leo [1 ]
Kraemer, Stefan Daniel [1 ,2 ]
Gensch, Nicole [4 ]
van der Kooi, Alexander [6 ]
Reinemann, Christine [7 ,10 ]
O'Sullivan, Ciara [8 ,9 ]
Svobodova, Marketa [8 ]
Roth, Guenter [1 ,2 ,3 ,5 ]
机构
[1] Univ Freiburg, Ctr Biol Syst Anal, Lab Microarray Copying, ZBSA, Habsburgerstr 49, D-79104 Freiburg, Germany
[2] Univ Freiburg, Fac Biol, Schanzlestr 1, D-79104 Freiburg, Germany
[3] Univ Freiburg, Ctr Biol Signaling Studies BIOSS, D-79104 Freiburg, Germany
[4] Univ Freiburg, Ctr Biol Signaling Studies BIOSS, Core Facil Signalling Factory, D-79104 Freiburg, Germany
[5] BioCopy GmbH, D-79110 Freiburg, Germany
[6] IBIS Technol Bv, NL-7521 PR Enschede, Netherlands
[7] Helmholtz Ctr Environm Res GmbH UFZ, Permoserstr 15, D-04318 Leipzig, Germany
[8] Univ Rovira & Virgili, Dept Engn Quim, E-43007 Tarragona, Spain
[9] Inst Catalana Recerca & Estudis Avancats, Barcelona 08010, Spain
[10] Aptamer Grp Ltd, Bio Ctr, Innovat Way, York YO10 5NY, N Yorkshire, England
关键词
Thrombin aptamer; Label-free; Reflecto-interferometry; BioLayer interferometry; Surface plasmon resonance; MicroScale thermophoresis; KINETICS; RECOGNITION; ADSORPTION; FIBRINOGEN; AFFINITY; PCR;
D O I
10.1016/j.ab.2019.05.012
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
To enable the analysis of several hundreds to thousands of interactions in parallel, high-throughput systems were developed. We used established thrombin aptamer assays to compare three such high-throughput imaging systems as well as analysis software and user influence. In addition to our own iRIf-system, we applied bscreen and IBIS-MX96. As non-imaging reference systems we used Octet-RED96, Biacore3000, and Monolith-NT.115. In this study we measured 1378 data points. Our results show that all systems are suitable for analyzing binding kinetics, but the kinetic constants as well as the ranking of the selected aptamers depend significantly on the applied system and user. We provide an insight into the signal generation principles, the systems and the results generated for thrombin aptamers. It should contribute to the awareness that binding constants cannot be determined as easily as other constants. Since many parameters like surface chemistry, biosensor type and buffer composition may change binding behavior, the experimenter should be aware that a system and assay dependent K-D is determined. Frequently, certain conditions that are best suited for a given biosensing system cannot be transferred to other systems. Therefore, we strongly recommend using at least two different systems in parallel to achieve meaningful results.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] High-Throughput Label-Free Enzymatic Assays Using Desorption Electrospray-Ionization Mass Spectrometry
    Morato, Nicolas M.
    Holden, Dylan T.
    Cooks, R. Graham
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2020, 59 (46) : 20459 - 20464
  • [22] Modulating Cell-Cell Communication with a High-Throughput Label-Free Cell Assay
    Li, Guangshan
    Lai, Fang
    Fang, Ye
    JALA, 2012, 17 (01): : 6 - 15
  • [23] CSI-FID: High throughput label-free detection of DNA binding molecules
    Hauschild, Karl E.
    Stover, James S.
    Boger, Dale L.
    Ansari, Aseem Z.
    BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 2009, 19 (14) : 3779 - 3782
  • [24] Systems biology coupled with label-free high-throughput detection as a novel approach for diagnosis of chronic obstructive pulmonary disease
    Richens, Joanna L.
    Urbanowicz, Richard A.
    Lunt, Elizabeth A. M.
    Metcalf, Rebecca
    Corne, Jonathan
    Fairclough, Lucy
    O'Shea, Paul
    RESPIRATORY RESEARCH, 2009, 10
  • [25] Systems biology coupled with label-free high-throughput detection as a novel approach for diagnosis of chronic obstructive pulmonary disease
    Joanna L Richens
    Richard A Urbanowicz
    Elizabeth AM Lunt
    Rebecca Metcalf
    Jonathan Corne
    Lucy Fairclough
    Paul O'Shea
    Respiratory Research, 10
  • [26] Label-free profiling of DNA aptamer-small molecule binding using T5 exonuclease
    Alkhamis, Obtin
    Yang, Weijuan
    Farhana, Rifat
    Yu, Haixiang
    Xiao, Yi
    NUCLEIC ACIDS RESEARCH, 2020, 48 (20) : E120 - E120
  • [27] Kinetic and Equilibrium Binding Characterization of Aptamers to Small Molecules using a Label-Free, Sensitive, and Scalable Platform
    Chang, Andrew L.
    McKeague, Maureen
    Liang, Joe C.
    Smoke, Christina D.
    ANALYTICAL CHEMISTRY, 2014, 86 (07) : 3273 - 3278
  • [28] Screening for lysine-specific demethylase-1 inhibitors using a label-free high-throughput mass spectrometry assay
    Plant, Matthew
    Dineen, Tom
    Cheng, Alan
    Long, Alexander M.
    Chen, Hao
    Morgenstern, Kurt A.
    ANALYTICAL BIOCHEMISTRY, 2011, 419 (02) : 217 - 227
  • [29] LABEL-FREE DETECTION OF PROTEIN MICROARRAY WITH HIGH THROUGHPUT SURFACE PLASMON RESONANCE IMAGING (SPRI)
    Xu, Shukuan
    Huang, Guoliang
    Deng, Cheng
    Zhu, Jiang
    Han, Chao
    Yang, Xiaoyong
    JOURNAL OF INNOVATIVE OPTICAL HEALTH SCIENCES, 2008, 1 (01) : 107 - 114
  • [30] Label-free, high-throughput detection of P-falciparum infection in sphered erythrocytes with digital holographic microscopy
    Ugele, Matthias
    Weniger, Markus
    Leidenberger, Maria
    Huang, Yiwei
    Bassler, Michael
    Friedrich, Oliver
    Kappes, Barbara
    Hayden, Oliver
    Richter, Lukas
    LAB ON A CHIP, 2018, 18 (12) : 1704 - 1712