Sample introduction systems for reversed phase LC-ICP-MS of selenium using large amounts of methanol - comparison of systems based on membrane desolvation, a spray chamber and direct injection

被引:30
作者
Bendahl, L [1 ]
Gammelgaard, B [1 ]
机构
[1] Danish Univ Pharmaceut Sci, Dept Analyt Chem, DK-2100 Copenhagen, Denmark
关键词
D O I
10.1039/b415717f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three sample introduction systems were compared for their efficiency in introducing a variety of biologically relevant selenium species in organic solutions with the purpose of mimicking the effluent from a chromatographic system. The sample introduction systems consisted of a microconcentric nebuliser (MCN) in combination with a membrane desolvator ( MD), a MCN in combination with a cyclonic spray chamber ( CS) and a direct injection nebuliser ( DIN), respectively. Thirteen selenium standards diluted in 50% methanol were introduced in each system at a flow rate of 50 mu l min(-1). Except for the selenite and methaneseleninic acid standards that were lost in the MCN-MD system, similar normalized response factors were achieved for the standards regardless of the sample introduction system. When trimethylselenonium and selenate standards were continuously infused in a linear methanol gradient from 10 to 90%, the signal was almost unaffected when the MCN-MD was used as interface. The signals from the MCN-CS introduction system were almost unaffected in methanol concentrations between 10 and 40%, after which they slowly declined. The signal from the DIN showed a plateau in signal intensity at methanol concentrations between 35 and 70%. Detection limits in flow injection analysis, expressed as the concentration that would result in a signal equivalent to three times the peak to peak noise of the baseline, were estimated to be 200, 150 and 100 ng Se L-1 for the MCN-CS, MCN-MD and DIN, respectively. The independence of the signal from the methanol concentration in the eluent allowed quanti. cation of human selenoprotein P isoforms by gradient microbore reversed phase chromatography (mu RPC) on the basis of an internal trimethylselenonium standard. The MCN-MD system was applied for mu RPC analysis of Se-77 enriched yeast samples and more than 30 selenium containing compounds were separated using a linear gradient from 5% to 95% methanol, some of the selenium species eluting in 85% methanol.
引用
收藏
页码:410 / 416
页数:7
相关论文
共 32 条
[21]   Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry [J].
Niu, H ;
Houk, RS .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (08) :779-815
[22]   Oxidative production of monomethylated selenium from the major urinary selenometabolite, selenosugar [J].
Ogra, Y ;
Hatano, T ;
Ohmichi, M ;
Suzuki, KT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (10) :1252-1255
[23]   Identification of a novel selenium metabolite, Se-methyl-N-acetylselenohexosamine, in rat urine by high-performance liquid chromatography-inductively coupled plasma mass spectrometry and -electrospray ionization tandem mass spectrometry [J].
Ogra, Y ;
Ishiwata, K ;
Takayama, H ;
Aimi, N ;
Suzuki, KT .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (02) :301-312
[24]  
PING L, 1985, ANAL SCI, V1, P257
[25]   A systematic approach to selenium speciation in, selenized yeast [J].
Polatajko, A ;
Sliwka-Kaszynska, M ;
Dernovics, M ;
Ruzik, R ;
Encinar, JR ;
Szpunar, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2004, 19 (01) :114-120
[26]   The argument for increasing selenium intake [J].
Rayman, MP .
PROCEEDINGS OF THE NUTRITION SOCIETY, 2002, 61 (02) :203-215
[27]   ELEMENTAL SPECIATION BY LIQUID-CHROMATOGRAPHY INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY WITH DIRECT INJECTION NEBULIZATION [J].
SHUM, SCK ;
NEDDERSEN, R ;
HOUK, RS .
ANALYST, 1992, 117 (03) :577-582
[28]   Comparison of different transition metal ions for immobilized metal affinity chromatography of selenoprotein P from human plasma [J].
Sidenius, U ;
Farver, O ;
Jons, O ;
Gammelgaard, B .
JOURNAL OF CHROMATOGRAPHY B, 1999, 735 (01) :85-91
[29]   Steady state acid effects in ICP-MS [J].
Stewart, II ;
Olesik, JW .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) :1313-1320
[30]   Modified direct injection high efficiency nebulizer with minimized dead volume for the analysis of biological samples by micro- and nano-LC-ICP-MS [J].
Wind, M ;
Eisenmenger, A ;
Lehmann, WD .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (01) :21-26