Noise Reduction in Dual-Energy Contrast Enhanced Digital Breast Tomosynthesis Using Regularization

被引:0
作者
Iordache, Razvan [1 ]
Lohezic, Maelene [1 ]
Palma, Giovanni [1 ]
Puong, Sylvie [1 ]
Muller, Serge [1 ]
机构
[1] GE Healthcare, F-78533 Buc, France
来源
DIGITAL MAMMOGRAPHY | 2010年 / 6136卷
关键词
digital breast tomosynthesis; dual energy; iodine imaging; functional imaging; RECONSTRUCTION; CONVERGENCE; ALGORITHMS;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Dual-Energy Contrast Enhanced Digital breast tomosynthesis is an emerging technique for breast cancer detection, which combines the strengths of functional and morphological 3D imaging. The projection images acquired with two energy spectra at several angulations are combined to obtain "iodine" projections. These are then reconstructed to provide 3D iodine images. The combination process significantly increases the noise in the images, which is further amplified by the 3D reconstruction. This paper proposes a regularized reconstruction method based on the simultaneous algebraic reconstruction technique to be used for the reconstruction of the iodine volume. The regularization represents a constraint for the reconstructed volume, which causes the reduction of the noise and preserves the structures of interest. Preliminary results on clinical data demonstrate a significant increase of the visibility of iodine-enhanced regions without affecting their sharpness and morphology.
引用
收藏
页码:92 / 99
页数:8
相关论文
共 50 条
[1]   A scatter correction method for contrast-enhanced dual-energy digital breast tomosynthesis [J].
Lu, Yihuan ;
Peng, Boyu ;
Lau, Beverly A. ;
Hu, Yue-Houng ;
Scaduto, David A. ;
Zhao, Wei ;
Gindi, Gene .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (16) :6323-6354
[2]   Segmentation methods for breast vasculature in dual-energy contrast-enhanced digital breast tomosynthesis [J].
Lau, Kristen C. ;
Lee, Hyo Min ;
Singh, Tanushriya ;
Maidment, Andrew D. A. .
MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
[3]   Dual-energy contrast enhanced digital breast tomosynthesis: concept, method and evaluation on phantoms [J].
Puong, Sylvie ;
Patoureaux, Fanny ;
Iordache, Razvan ;
Bouchevreau, Xavier ;
Muller, Serge .
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
[4]   Impact of subtraction and reconstruction strategies on dual-energy contrast enhanced breast tomosynthesis with interleaved acquisition [J].
Chen, Lin ;
Lu, Yihuan ;
Hu, Yue-Houng ;
Zhao, Wei ;
Gindi, Gene .
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
[5]   Optimization of beam parameters and iodine quantification in dual-energy contrast enhanced digital breast tomosynthesis [J].
Puong, Sylvie ;
Bouchevreau, Xavier ;
Duchateau, Nicolas ;
Iordache, Razvan ;
Muller, Serge .
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
[6]   Experimental quantification of lesion detectability in contrast enhanced dual energy digital breast tomosynthesis [J].
Hu, Yue-Houng ;
Zhao, Wei .
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
[7]   Quantitative evaluation of breast density using a dual-energy technique on a digital breast tomosynthesis system [J].
Lu, Kun-Mu ;
Yeh, Da-Ming ;
Cao, Bi-Hui ;
Lin, Chia-Yi ;
Lian, Chih-Yu ;
Zhou, Yu-Bo ;
Tsai, Chia-Jung .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (06) :170-177
[8]   Design of a contrast-enhanced dual-energy tomosynthesis system for breast cancer imaging [J].
Hoernig, M. D. ;
Baetz, L. ;
Mertelmeier, T. .
MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
[9]   Effects of image lag and scatter for dual-energy contrast-enhanced digital breast tomosynthesis using a CsI flat-panel based system [J].
Carton, Ann-Katherine ;
Puong, Sylvie ;
Iordache, Razvan ;
Muller, Serge .
MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
[10]   A simple scatter correction method for dual energy contrast-enhanced digital breast tomosynthesis [J].
Lu, Yihuan ;
Lau, Beverly ;
Hu, Yue-Houng ;
Zhao, Wei ;
Gindi, Gene .
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033