Effects of Rapid On-Site Evaluation on Diagnostic Accuracy of Thyroid Fine-Needle Aspiration

被引:7
|
作者
Fawcett, Celia [1 ]
Eppenberger-Castori, Serenella [2 ]
Zechmann, Stefan [1 ]
Hanke, Jasmin [2 ]
Herzog, Michelle [2 ]
Prince, Spasenija Savic [2 ]
Christ, Emanuel Remigius [1 ]
Ebrahimi, Fahim [1 ,3 ]
机构
[1] Univ Hosp Basel, Div Endocrinol Diabet & Metab, Basel, Switzerland
[2] Univ Hosp Basel, Inst Med Genet & Pathol, Pathol, Basel, Switzerland
[3] Univ Ctr Gastrointestinal & Liver Dis, Clarunis, Basel, Switzerland
关键词
Thyroid nodule; Fine-needle aspiration; On-site evaluation; Cytology;
D O I
10.1159/000522662
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Introduction: Fine-needle aspiration (FNA) is well-established for the evaluation of suspicious thyroid nodules. However, a significant proportion is nondiagnostic. Rapid on-site evaluation (ROSE) has been proposed to improve the overall adequacy of FNA. Methods: Retrospective cohort study comparing adequacy of thyroid FNA findings pre- and post-implementation of ROSE at a tertiary center in Switzerland. Patients undergoing thyroid FNA from January 2016 to December 2019 were included. The primary outcome was the rate of nondiagnostic findings (Bethesda System for Reporting Thyroid Cytopathology category I). Results: In total, 410 thyroid nodule FNAs were performed. Of those, 309 with standard FNA and 101 with ROSE. The majority of patients were female (71%), with a median age of 56 years (IQR 46-68) and a nodule diameter of 1.9 cm (IQR 1.2-2.9). Implementation of ROSE led to a decrease in nondiagnostic findings from 41.1% to 23.8%, with an odds ratio of 0.42 (95% CI: 0.24-0.72; p = 0.002). Implementation of ROSE was associated with significantly higher rates of Bethesda category III (27.7% vs. 19.1%), category IV (15.8% vs. 5.5%), and Bethesda category VI (6.9% vs. 2.3%). Repeated FNA was performed in 29.1% before and 20.8% after implementation of ROSE (p = 0.18). The mean number of FNA per nodule was reduced from 1.4 (0.6) to 1.2 (0.4) with ROSE (p = 0.04). Conclusions: Implementation of ROSE of thyroid nodule specimen improved diagnostic adequacy of FNA, reducing nondiagnostic findings. However, due to increased equivocal findings (Bethesda category III), there was no significant reduction of repeat FNA. (c) 2022 The Author(s). Published by S. Karger AG, Basel
引用
收藏
页码:371 / 378
页数:8
相关论文
共 50 条
  • [1] Fine-needle aspiration of thyroid and diagnostic accuracy
    Singh, Preeti
    Rathi, Monika
    Jaiswal, Vijay
    Verma, Nidhi
    Gupta, Priya
    Karuna, Veer
    Verma, Snehlata
    INTERNATIONAL JOURNAL OF HEALTH AND ALLIED SCIENCES, 2020, 9 (03): : 223 - 228
  • [2] The Impact of Rapid On-Site Evaluation on the Quality and Diagnostic Value of Thyroid Nodule Fine-Needle Aspirations
    Muri, Raphaela
    Trippel, Mafalda
    Borner, Urs
    Weidner, Sabine
    Trepp, Roman
    THYROID, 2022, 32 (06) : 667 - 674
  • [3] Rapid On-Site Evaluation of Fine-Needle Aspiration by Non-Cytopathologists: A Systematic Review and Meta-Analysis of Diagnostic Accuracy Studies for Adequacy Assessment
    Pearson, Lauren
    Factor, Rachel E.
    White, Sandra K.
    Walker, Brandon S.
    Layfield, Lester J.
    Schmidt, Robert L.
    ACTA CYTOLOGICA, 2018, 62 (04) : 244 - 252
  • [4] Diagnostic Accuracy of Ultrasonography in Classifying Thyroid Nodules Compared with Fine-Needle Aspiration
    Al-Ghanimi, Ibrahim Abobaker
    Al-Sharydah, Abdulaziz Mohammad
    Al-Mulhim, Saqar
    Faisal, Sarah
    Al-Abdulwahab, Abdulrahman
    Al-Aftan, Mohammed
    Abuhaimed, Abdulrahman
    SAUDI JOURNAL OF MEDICINE & MEDICAL SCIENCES, 2020, 8 (01): : 25 - 31
  • [5] The impact of rapid on-site evaluation on thyroid fine-needle aspiration biopsy: A 2-year cancer center institutional experience
    Pastorello, Ricardo G.
    Destefani, Camila
    Pinto, Pedro H.
    Credidio, Caroline H.
    Reis, Rafael X.
    Rodrigues, Thiago de A.
    de Toledo, Maryane C.
    De Brot, Louise
    Costa, Felipe de A.
    do Nascimento, Antonio G.
    Pinto, Clovis A. L.
    Saieg, Mauro A.
    CANCER CYTOPATHOLOGY, 2018, 126 (10) : 846 - 852
  • [6] When Is Rapid On-Site Evaluation Cost-Effective for Fine-Needle Aspiration Biopsy?
    Schmidt, Robert L.
    Walker, Brandon S.
    Cohen, Michael B.
    PLOS ONE, 2015, 10 (08):
  • [7] Value of rapid on-site evaluation for ultrasound-guided thyroid fine needle aspiration
    Jiang, Danni
    Zang, Yichen
    Jiang, Dandan
    Zhang, Xiaojuan
    Zhao, Cheng
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2019, 47 (02) : 626 - 634
  • [8] Diagnostic Accuracy of Ultrasound and Fine-Needle Aspiration Cytology in Thyroid Malignancy
    Boudina, Maria
    Katsamakas, Michael
    Chorti, Angeliki
    Panousis, Panagiotis
    Tzitzili, Eleni
    Tzikos, Georgios
    Chrisoulidou, Alexandra
    Valeri, Rosalia
    Ioannidis, Aris
    Papavramidis, Theodossis
    MEDICINA-LITHUANIA, 2024, 60 (05):
  • [9] Performance of Rapid On-Site Evaluation in Breast Fine-Needle Aspiration Biopsies: Identifying Areas of Diagnostic Challenge
    Torous, Vanda F.
    Lopez, Silvia Huerta
    Xu, Christine
    Sweeney, Brenda J.
    Pitman, Martha B.
    ACTA CYTOLOGICA, 2022, 66 (01) : 1 - 13
  • [10] Impact of rapid on-site evaluation on diagnostic accuracy of EUS-guided fine-needle aspiration of solid pancreatic lesions: experience from a single center
    Guvendir, Irem
    Zemheri, Itir Ebru
    Ozdil, Kamil