A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations

被引:36
|
作者
Schabel, Matthias C. [1 ]
Fluckiger, Jacob U. [1 ]
DiBella, Edward V. R. [1 ]
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
关键词
REFERENCE TISSUE METHOD; REFERENCE REGION MODEL; KINETIC-PARAMETERS; RHEUMATOID-ARTHRITIS; PERFUSION MRI; DCE-MRI; GRADIENT-ECHO; VASCULAR-PERMEABILITY; BLOOD-VOLUME; QUANTIFICATION;
D O I
10.1088/0031-9155/55/16/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Widespread adoption of quantitative pharmacokinetic modeling methods in conjunction with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has led to increased recognition of the importance of obtaining accurate patient-specific arterial input function (AIF) measurements. Ideally, DCE-MRI studies use an AIF directly measured in an artery local to the tissue of interest, along with measured tissue concentration curves, to quantitatively determine pharmacokinetic parameters. However, the numerous technical and practical difficulties associated with AIF measurement have made the use of population-averaged AIF data a popular, if sub-optimal, alternative to AIF measurement. In this work, we present and characterize a new algorithm for determining the AIF solely from the measured tissue concentration curves. This Monte Carlo blind estimation (MCBE) algorithm estimates the AIF from the subsets of D concentration-time curves drawn from a larger pool of M candidate curves via nonlinear optimization, doing so for multiple (Q) subsets and statistically averaging these repeated estimates. The MCBE algorithm can be viewed as a generalization of previously published methods that employ clustering of concentration-time curves and only estimate the AIF once. Extensive computer simulations were performed over physiologically and experimentally realistic ranges of imaging and tissue parameters, and the impact of choosing different values of D and Q was investigated. We found the algorithm to be robust, computationally efficient and capable of accurately estimating the AIF even for relatively high noise levels, long sampling intervals and low diversity of tissue curves. With the incorporation of bootstrapping initialization, we further demonstrated the ability to blindly estimate AIFs that deviate substantially in shape from the population-averaged initial guess. Pharmacokinetic parameter estimates for K-trans, k(ep), v(p) and v(e) all showed relative biases and uncertainties of less than 10% for measurements having a temporal sampling rate of 4 s and a concentration measurement noise level of sigma = 0.04 mM. A companion paper discusses the application of the MCBE algorithm to DCE-MRI data acquired in eight patients with malignant brain tumors.
引用
收藏
页码:4783 / 4806
页数:24
相关论文
共 50 条
  • [21] Dynamic contrast-enhanced MRI parametric mapping using high spatiotemporal resolution Golden-angle RAdial Sparse Parallel MRI and iterative joint estimation of the arterial input function and pharmacokinetic parameters
    Mazaheri, Yousef
    Kim, Nathanael
    Lakhman, Yulia
    Jafari, Ramin
    Vargas, Alberto
    Otazo, Ricardo
    NMR IN BIOMEDICINE, 2022, 35 (07)
  • [22] A method for interleaved acquisition of a vascular input function for dynamic contrast-enhanced MRI in experimental rat tumours
    McIntyre, DJO
    Ludwig, C
    Pasan, A
    Griffiths, JR
    NMR IN BIOMEDICINE, 2004, 17 (03) : 132 - 143
  • [23] Improving the Arterial Input Function in Dynamic Contrast Enhanced MRI by Fitting the Signal in the Complex Plane
    Simonis, Frank F. J.
    Sbrizzi, Alessandro
    Beld, Ellis
    Lagendijk, Jan J. W.
    van den Berg, Cornelis A. T.
    MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) : 1236 - 1245
  • [24] Quantitative Estimation of Renal Function with Dynamic Contrast-Enhanced MRI Using a Modified Two-Compartment Model
    Chen, Bin
    Zhang, Yudong
    Song, Xiaojian
    Wang, Xiaoying
    Zhang, Jue
    Fang, Jing
    PLOS ONE, 2014, 9 (08):
  • [25] Estimation of the capillary level input function for dynamic contrast-enhanced MRI of the breast using a deep learning approach
    Bae, Jonghyun
    Huang, Zhengnan
    Knoll, Florian
    Geras, Krzysztof
    Sood, Terlika Pandit
    Feng, Li
    Heacock, Laura
    Moy, Linda
    Kim, Sungheon Gene
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (05) : 2536 - 2550
  • [26] A simulation study comparing nine mathematical models of arterial input function for dynamic contrast enhanced MRI to the Parker model
    He, Dianning
    Xu, Lisheng
    Qian, Wei
    Clarke, James
    Fan, Xiaobing
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2018, 41 (02) : 507 - 518
  • [27] Effect of parallel radiofrequency transmission on arterial input function selection in dynamic contrast-enhanced 3 Tesla pelvic MRI
    Chafi, Hatim
    Elias, Saba N.
    Nguyen, Huyen T.
    Friel, Harry T.
    Knopp, Michael V.
    Guo, BeiBei
    Heymsfield, Steven B.
    Jia, Guang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (01) : 229 - 235
  • [28] Response-Derived Input Function Estimation for Dynamic Contrast-Enhanced MRI Demonstrated by Anti-DLL4 Treatment in a Murine U87 Xenograft Model
    Silva, Matthew D.
    Yerby, Brittany
    Moriguchi, Jodi
    Gomez, Albert
    Jun, H. Toni
    Coxon, Angela
    Ungersma, Sharon E.
    MOLECULAR IMAGING AND BIOLOGY, 2017, 19 (05) : 673 - 682
  • [29] Improving the pharmacokinetic parameter measurement in dynamic contrast-enhanced MRI by use of the arterial input function: Theory and clinical application
    Yang, Xiangyu
    Liang, Jiachao
    Heverhagen, Johannes T.
    Jia, Guang
    Schmalbrock, Petra
    Sammet, Steffen
    Koch, Regina
    Knopp, Michael V.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (06) : 1448 - 1456
  • [30] Automatic Determination of Arterial Input Function for Dynamic Contrast Enhanced MRI in Tumor Assessment
    Chen, Jeremy
    Yao, Jianhua
    Thornasson, David
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2008, PT I, PROCEEDINGS, 2008, 5241 : 594 - 601