A model-constrained Monte Carlo method for blind arterial input function estimation in dynamic contrast-enhanced MRI: I. Simulations

被引:36
作者
Schabel, Matthias C. [1 ]
Fluckiger, Jacob U. [1 ]
DiBella, Edward V. R. [1 ]
机构
[1] Univ Utah, Hlth Sci Ctr, Dept Radiol, Utah Ctr Adv Imaging Res, Salt Lake City, UT 84108 USA
关键词
REFERENCE TISSUE METHOD; REFERENCE REGION MODEL; KINETIC-PARAMETERS; RHEUMATOID-ARTHRITIS; PERFUSION MRI; DCE-MRI; GRADIENT-ECHO; VASCULAR-PERMEABILITY; BLOOD-VOLUME; QUANTIFICATION;
D O I
10.1088/0031-9155/55/16/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Widespread adoption of quantitative pharmacokinetic modeling methods in conjunction with dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has led to increased recognition of the importance of obtaining accurate patient-specific arterial input function (AIF) measurements. Ideally, DCE-MRI studies use an AIF directly measured in an artery local to the tissue of interest, along with measured tissue concentration curves, to quantitatively determine pharmacokinetic parameters. However, the numerous technical and practical difficulties associated with AIF measurement have made the use of population-averaged AIF data a popular, if sub-optimal, alternative to AIF measurement. In this work, we present and characterize a new algorithm for determining the AIF solely from the measured tissue concentration curves. This Monte Carlo blind estimation (MCBE) algorithm estimates the AIF from the subsets of D concentration-time curves drawn from a larger pool of M candidate curves via nonlinear optimization, doing so for multiple (Q) subsets and statistically averaging these repeated estimates. The MCBE algorithm can be viewed as a generalization of previously published methods that employ clustering of concentration-time curves and only estimate the AIF once. Extensive computer simulations were performed over physiologically and experimentally realistic ranges of imaging and tissue parameters, and the impact of choosing different values of D and Q was investigated. We found the algorithm to be robust, computationally efficient and capable of accurately estimating the AIF even for relatively high noise levels, long sampling intervals and low diversity of tissue curves. With the incorporation of bootstrapping initialization, we further demonstrated the ability to blindly estimate AIFs that deviate substantially in shape from the population-averaged initial guess. Pharmacokinetic parameter estimates for K-trans, k(ep), v(p) and v(e) all showed relative biases and uncertainties of less than 10% for measurements having a temporal sampling rate of 4 s and a concentration measurement noise level of sigma = 0.04 mM. A companion paper discusses the application of the MCBE algorithm to DCE-MRI data acquired in eight patients with malignant brain tumors.
引用
收藏
页码:4783 / 4806
页数:24
相关论文
共 55 条
[1]   The effects of renal variation upon measurements of perfusion and leakage volume in breast tumours [J].
Ahearn, TS ;
Staff, RT ;
Redpath, TW ;
Semple, SIK .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (10) :2041-2051
[2]   AZD2171, a pan-VEGF receptor tyrosine kinase inhibitor, normalizes tumor vasculature and alleviates edema in glioblastoma patients [J].
Batchelor, Tracy T. ;
Sorensen, A. Gregory ;
di Tomaso, Emmanuelle ;
Zhang, Wei-Ting ;
Duda, Dan G. ;
Cohen, Kenneth S. ;
Kozak, Kevin R. ;
Cahill, Daniel P. ;
Chen, Poe-Jou ;
Zhu, Mingwang ;
Ancukiewicz, Marek ;
Mrugala, Maciej M. ;
Plotkin, Scott ;
Drappatz, Jan ;
Louis, David N. ;
Ivy, Percy ;
Scadden, David T. ;
Benner, Thomas ;
Loeffler, Jay S. ;
Wen, Patrick Y. ;
Jain, Rakesh K. .
CANCER CELL, 2007, 11 (01) :83-95
[3]   Bolus delay and dispersion in perfusion MRI: Implications for tissue predictor models in stroke [J].
Calamante, F ;
Willats, L ;
Gadian, DG ;
Connelly, A .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (05) :1180-1185
[4]   Defining a local arterial input function for perfusion MRI using independent component analysis [J].
Calamante, F ;
Morup, M ;
Hansen, LK .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) :789-797
[5]   A complete NMR spectral assignment of the conserved region of the MESD protein, MESD(12-155) [J].
Chen, Jianglei ;
Bu, Guojun ;
Wang, Jianjun .
BIOMOLECULAR NMR ASSIGNMENTS, 2007, 1 (01) :3-5
[6]   Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI [J].
Cheng, Hai-Ling Margaret .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) :736-743
[7]  
Di Bella EVR, 1999, PHYS MED BIOL, V44, P765, DOI 10.1088/0031-9155/44/3/018
[8]  
Evelhoch JL, 1999, JMRI-J MAGN RESON IM, V10, P254, DOI 10.1002/(SICI)1522-2586(199909)10:3<254::AID-JMRI5>3.0.CO
[9]  
2-9
[10]  
Feng D, 1997, IEEE Trans Inf Technol Biomed, V1, P243, DOI 10.1109/4233.681168