Experimental Investigation of Long-term Reliability for Temperature Monitoring in the Air Conditioning and Mechanical Ventilation Systems

被引:0
作者
Wang, Zhe [1 ,3 ]
Cai, Wenjian [2 ]
Hong, Wei [4 ,5 ,6 ]
Koh, Leong Hai [3 ]
Shen, Suping [2 ]
Wang, Xinli [7 ]
机构
[1] Dalian Maritime Univ, Marine Engn Coll, Dalian 116026, Peoples R China
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Singapore 639798, Singapore
[3] Nanyang Technol Univ, Energy Res Inst, Singapore 639798, Singapore
[4] Huazhong Univ Sci & Technol, MOE Key Lab Fundamental Phys Quant Measurement, Wuhan 430074, Peoples R China
[5] Huazhong Univ Sci & Technol, Hubei Key Lab Gravitat & Quantum Phys, PGMF, Wuhan 430074, Peoples R China
[6] Huazhong Univ Sci & Technol, Sch Phys, Wuhan 430074, Peoples R China
[7] Shandong Univ, Sch Control Sci & Engn, Jinan 250061, Peoples R China
来源
PROCEEDINGS OF THE 2019 14TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA 2019) | 2019年
基金
新加坡国家研究基金会;
关键词
Temperature sensor; measurement; long-term reliability; air conditioning & mechanical ventilation; BALANCING METHOD; COMFORT;
D O I
10.1109/iciea.2019.8834262
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Temperature is a crucial variable to evaluate and measure the energy consumption and efficiency of the Air Conditioning & Mechanical Ventilation System (ACMVS) in the buildings. To ensure the performance and efficiency of the ACMVS, an experimental study of long-term reliability for temperature monitoring to ensure the accuracy of temperature sensor measurement is carried out in this paper. Four experiments were conducted for the influence of temperature measurement under different operating conditions in the ACMVS, which are insertion depth, humidity, tube vibration, and water mixing. Finally, the drift of two types of temperature sensors (RTD and Thermistor) commonly used in industry are compared under the condition of long-term reliability measurement. The results showed that the non-waterproof thermistor installed on the open thermocouple sleeve at least 2/3 of the pipe where the temperature sensor is inserted at 10D away from the water mixing point could provide the best temperature reading.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 18 条
[1]   Energy efficiency index as an indicator for measuring building energy performance: A review [J].
Abu Bakar, Nur Najihah ;
Hassan, Mohammad Yusri ;
Abdullah, Hayati ;
Rahman, Hasimah Abdul ;
Abdullah, Md Pauzi ;
Hussin, Faridah ;
Bandi, Masilah .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 44 :1-11
[2]   Experimental and numerical investigations of thermal performance of a Hemp Lime external building insulation [J].
Costantine, Georges ;
Maalouf, Chadi ;
Moussa, Tala ;
Polidori, Guillaume .
BUILDING AND ENVIRONMENT, 2018, 131 :140-153
[3]   Chiller: Performance deterioration and maintenance [J].
Firdaus N. ;
Prasetyo B.T. ;
Luciana T. .
Energy Engineering: Journal of the Association of Energy Engineering, 2016, 113 (04) :55-80
[4]  
Hong W, 2018, C IND ELECT APPL, P1709, DOI 10.1109/ICIEA.2018.8397985
[5]   An air balancing method using support vector machine for a ventilation system [J].
Jing, Gang ;
Cai, Wenjian ;
Chen, Haoran ;
Zhai, Deqing ;
Cui, Can ;
Yin, Xiaohong .
BUILDING AND ENVIRONMENT, 2018, 143 :487-495
[6]   A model-based air balancing method of a ventilation system [J].
Jing, Gang ;
Cai, Wenjian ;
Zhai, Deqing ;
Liu, Shuai ;
Cui, Can .
ENERGY AND BUILDINGS, 2018, 174 :506-512
[7]  
Ke J, 2018, 2018 13 IEEE C IND E, P1609
[8]   Occupancy measurement in commercial office buildings for demand-driven control applications-A survey and detection system evaluation [J].
Labeodan, Timilehin ;
Zeiler, Wim ;
Boxem, Gert ;
Zhao, Yang .
ENERGY AND BUILDINGS, 2015, 93 :303-314
[9]   An autonomous hierarchical control for improving indoor comfort and energy efficiency of a direct expansion air conditioning system [J].
Mei, Jun ;
Xia, Xiaohua ;
Song, Mengjie .
APPLIED ENERGY, 2018, 221 :450-463
[10]   Experimental investigations on heat and mass transfer performances of a liquid desiccant cooling and dehumidification system [J].
Ou, Xianhua ;
Cai, Wenjian ;
He, Xiongxiong ;
Zhai, Deqing .
APPLIED ENERGY, 2018, 220 :164-175