Three-dimensional constructive interference in steady-state magnetic resonance imaging in syringomyelia: advantages over conventional imaging

被引:31
|
作者
Roser, Florian [1 ]
Ebner, Florian H. [1 ]
Danz, Soren [2 ]
Riether, Felix [1 ]
Ritz, Rainer [1 ]
Dietz, Klaus [3 ]
Naegele, Thomas [2 ]
Tatagiba, Marcos S. [1 ]
机构
[1] Univ Tubingen, Dept Neurosurg, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Neuroradiol, D-72076 Tubingen, Germany
[3] Univ Tubingen, Dept Med Biomet, D-72076 Tubingen, Germany
关键词
computed tomography; constructive interference in steady-state imaging; magnetic resonance imaging; syringomyelia;
D O I
10.3171/SPI/2008/8/5/429
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Neuroradiology has become indispensable in detecting the pathophysiology in syringomyelia. Constructive interference in steady-state (CISS) magnetic resonance (MR) imaging can provide superior contrast at the subarachnoid tissue borders. As this region is critical in preoperative evaluation, the authors hypothesized that CISS imaging would provide superior assessment of syrinx pathology and surgical planning. Methods. Based on records collected from a database of 130 patients with syringomyelia treated at the authors' institution, 59 patients were prospectively evaluated with complete neuroradiological examinations. In addition to routine acquisitions with FLAIR, Tl- and T2-weighted, and contrast-enhanced MR imaging,series, the authors obtained sagittal cardiac-gated sequences to visualize cerebrospinal fluid (CSF) pulsations and axial 3D CISS MR sequences to detect focal arachnoid webs. Statistical qualitative and quantitative evaluations of spinal cord/CSF contrast, spinal cord/CSF delineation, motion artifacts, and artifacts induced by pulsatile CSF flow were performed. Results. The 3D CISS MR sequences demonstrated a contrast-to-noise ratio significantly better than any other routine imaging sequence (p < 0.001). Moreover, 3D CISS imaging can detect more subarachnoid webs and cavitations in the syrinx than T2-weighted MR imaging with less flow-void artifact. The limitation of 3D CISS imaging is a susceptibility to motion artifacts that can cause reduced spatial resolution. Lengthy acquisition times for axial segments can be reduced with multiplanar reconstruction of 3D CISS-generated sagittal images. Conclusions. Constructive interference in steady-state imaging is the MR sequence of choice in the preoperative evaluation of syringomyelia, allowing significantly higher detection rates of focal subarachnoid webs, whereas standard T2-weighted MR imaging shows turbulent CSF flow voids. Constructive interference in steady-state MR imaging enables the neurosurgeon to accurately identify cases requiring decompression for obstructed CSF. Motion artifacts can be eliminated with technical variations.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [21] Three-Dimensional Fat-Suppressed Steady-State Free Precession Imaging for Female Reproductive Organs
    Takatsu, Yasuo
    Okada, Tsutomu
    Miyati, Tosiaki
    Koyama, Takashi
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (03) : 746 - 752
  • [22] Three-dimensional magnetic resonance imaging of the postmortem fetal heart
    Deng, J
    Brookes, JAS
    Gardener, JE
    Rodeck, CH
    Lees, WR
    FETAL DIAGNOSIS AND THERAPY, 1996, 11 (06) : 417 - 421
  • [23] Three-dimensional magnetic resonance imaging of congenital cardiac anomalies
    Razavi, RS
    Hill, DLG
    Muthurangu, V
    Miquel, ME
    Taylor, AM
    Kozerke, S
    Baker, EJ
    CARDIOLOGY IN THE YOUNG, 2003, 13 (05) : 461 - 465
  • [24] Three-Dimensional Imaging of the Mouse Neurovasculature with Magnetic Resonance Microscopy
    Pathak, Arvind P.
    Kim, Eugene
    Zhang, Jiangyang
    Jones, Melina V.
    PLOS ONE, 2011, 6 (07):
  • [25] Contrast changes in portal vein and bile duct between centric and linear k-space ordering on three-dimensional segmented true fast imaging with steady-state precession magnetic resonance imaging
    Morita, Satoru
    Saito, Naoko
    Suzuki, Kazufumi
    Ohnishi, Takahiro
    Imura, Chiaki
    Mitsuhashi, Norio
    MAGNETIC RESONANCE IMAGING, 2008, 26 (09) : 1244 - 1249
  • [26] Detection of pseudoaneurysm of the left ventricle by fast imaging employing steady-state acquisition (FIESTA) magnetic resonance Imaging
    Rerkpattanapipat, P
    Mazur, W
    Link, KM
    Clark, HP
    Hundley, WG
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2003, 5 (02) : 399 - 402
  • [27] Effects of view ordering and dummy pulse rate on two-dimensional and three-dimensional steady-state free precession imaging
    Amano, Y
    Nozaki, A
    Kumazaki, T
    ACADEMIC RADIOLOGY, 2003, 10 (08) : 901 - 907
  • [28] Three-dimensional localization of impacted teeth using magnetic resonance imaging
    Tymofiyeva, O.
    Rottner, K.
    Jakob, P. M.
    Richter, E. -J.
    Proff, P.
    CLINICAL ORAL INVESTIGATIONS, 2010, 14 (02) : 169 - 176
  • [29] Three-dimensional localization of impacted teeth using magnetic resonance imaging
    O. Tymofiyeva
    K. Rottner
    P. M. Jakob
    E.-J. Richter
    P. Proff
    Clinical Oral Investigations, 2010, 14 : 169 - 176
  • [30] Magnetic resonance imaging of the coronary arteries: anatomy of the coronary arteries and veins in three-dimensional imaging
    van Geuns, RJM
    Wielopolski, PA
    Rensing, BJWM
    van Ooijen, PMA
    Oudkerk, M
    de Feyter, PJ
    CORONARY ARTERY DISEASE, 1999, 10 (04) : 261 - 267