Three-dimensional constructive interference in steady-state magnetic resonance imaging in syringomyelia: advantages over conventional imaging

被引:31
|
作者
Roser, Florian [1 ]
Ebner, Florian H. [1 ]
Danz, Soren [2 ]
Riether, Felix [1 ]
Ritz, Rainer [1 ]
Dietz, Klaus [3 ]
Naegele, Thomas [2 ]
Tatagiba, Marcos S. [1 ]
机构
[1] Univ Tubingen, Dept Neurosurg, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Neuroradiol, D-72076 Tubingen, Germany
[3] Univ Tubingen, Dept Med Biomet, D-72076 Tubingen, Germany
关键词
computed tomography; constructive interference in steady-state imaging; magnetic resonance imaging; syringomyelia;
D O I
10.3171/SPI/2008/8/5/429
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Neuroradiology has become indispensable in detecting the pathophysiology in syringomyelia. Constructive interference in steady-state (CISS) magnetic resonance (MR) imaging can provide superior contrast at the subarachnoid tissue borders. As this region is critical in preoperative evaluation, the authors hypothesized that CISS imaging would provide superior assessment of syrinx pathology and surgical planning. Methods. Based on records collected from a database of 130 patients with syringomyelia treated at the authors' institution, 59 patients were prospectively evaluated with complete neuroradiological examinations. In addition to routine acquisitions with FLAIR, Tl- and T2-weighted, and contrast-enhanced MR imaging,series, the authors obtained sagittal cardiac-gated sequences to visualize cerebrospinal fluid (CSF) pulsations and axial 3D CISS MR sequences to detect focal arachnoid webs. Statistical qualitative and quantitative evaluations of spinal cord/CSF contrast, spinal cord/CSF delineation, motion artifacts, and artifacts induced by pulsatile CSF flow were performed. Results. The 3D CISS MR sequences demonstrated a contrast-to-noise ratio significantly better than any other routine imaging sequence (p < 0.001). Moreover, 3D CISS imaging can detect more subarachnoid webs and cavitations in the syrinx than T2-weighted MR imaging with less flow-void artifact. The limitation of 3D CISS imaging is a susceptibility to motion artifacts that can cause reduced spatial resolution. Lengthy acquisition times for axial segments can be reduced with multiplanar reconstruction of 3D CISS-generated sagittal images. Conclusions. Constructive interference in steady-state imaging is the MR sequence of choice in the preoperative evaluation of syringomyelia, allowing significantly higher detection rates of focal subarachnoid webs, whereas standard T2-weighted MR imaging shows turbulent CSF flow voids. Constructive interference in steady-state MR imaging enables the neurosurgeon to accurately identify cases requiring decompression for obstructed CSF. Motion artifacts can be eliminated with technical variations.
引用
收藏
页码:429 / 435
页数:7
相关论文
共 50 条
  • [1] Value of constructive interference in steady-state, three-dimensional, Fourier transformation magnetic resonance imaging for the neuroendoscopic treatment of hydrocephalus and intracranial cysts
    Aleman, J
    Jokura, H
    Higano, S
    Akabane, A
    Shirane, R
    Yoshimoto, T
    NEUROSURGERY, 2001, 48 (06) : 1291 - 1295
  • [2] Real three-dimensional constructive interference in steady-state imaging to discern microneurosurgical anatomy - Technical note
    Kakizawa, Y
    Hongo, K
    Takasawa, H
    Miyairi, Y
    Sato, A
    Tanaka, Y
    Kobayashi, S
    JOURNAL OF NEUROSURGERY, 2003, 98 (03) : 625 - 630
  • [3] Evaluation of syringomyelia with three-dimensional constructive interference in a steady state (CISS) sequence
    Hirai, T
    Korogi, Y
    Shigematsu, Y
    Sugahara, T
    Takahashi, M
    Ushio, Y
    Uemura, S
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (02): : 120 - 126
  • [4] Three-dimensional fast imaging employing steady-state acquisition magnetic resonance imaging for lumbar synovial cysts
    Montano, Nicola
    Izzo, Alessandro
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2016, 50 (06) : 519 - 520
  • [5] Rapid three-dimensional steady-state chemical exchange saturation transfer magnetic resonance imaging
    Lee, Hoonjae
    Choi, Seung Hong
    Sohn, Chul-Ho
    Kim, Seong-Gi
    Lee, Joonyeol
    Park, Jaeseok
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (03) : 1209 - 1221
  • [6] Cavernous malformations of the brainstem: Three-dimensional-constructive interference in steady-state magnetic resonance imaging for improvement of surgical approach and clinical results
    Zausinger, S
    Yousry, I
    Brueckmann, H
    Schmid-Elsaesser, R
    Tonn, JC
    NEUROSURGERY, 2006, 58 (02) : 322 - 329
  • [7] Combining steady-state constructive interference and diffusion-weighted magnetic resonance imaging in the surgical treatment of epidermoid tumors
    Nobuya Murakami
    Toshio Matsushima
    Hiroshi Kuba
    Kiyonobu Ikezaki
    Takato Morioka
    Futoshi Mihara
    T. Inamura
    Masashi Fukui
    Neurosurgical Review, 1999, 22 : 159 - 162
  • [8] Combining steady-state constructive interference and diffusion-weighted magnetic resonance imaging in the surgical treatment of epidermoid tumors
    Murakami, N
    Matsushima, T
    Kuba, H
    Ikezaki, K
    Morioka, T
    Mihara, F
    Inamura, T
    Fukui, M
    NEUROSURGICAL REVIEW, 1999, 22 (2-3) : 159 - 162
  • [9] Steady-state magnetic resonance imaging in inner ear malformations
    Manfre, L
    Lagalla, R
    Quaranta, A
    Ferrara, S
    Riggio, F
    Garribba, AP
    Ettorre, GC
    INTERNATIONAL JOURNAL OF NEURORADIOLOGY, 1997, 3 (02): : 160 - 164
  • [10] Investigation of hydrocephalus with three-dimensional constructive interference in steady state MRI
    Kurihara, N
    Takahashi, S
    Tamura, H
    Higano, S
    Furuta, S
    Jokura, H
    Umetsu, A
    NEURORADIOLOGY, 2000, 42 (09) : 634 - 638