Electrochemical immunosensor detection of antigliadin antibodies from real human serum

被引:34
作者
Rosales-Rivera, L. C. [1 ]
Acero-Sanchez, J. L. [1 ]
Lozano-Sanchez, P. [1 ]
Katakis, I. [1 ]
O'Sullivan, C. K. [1 ,2 ]
机构
[1] Univ Rovira & Virgili, Dept Engn Quim, Tarragona 43007, Spain
[2] Inst Catalano Recerca & Estudis Avancats, Barcelona 08010, Spain
关键词
Electrochemical immunosensors; Self assembled monolayer (SAM); Antigliadin antibodies; Celiac disease; SELF-ASSEMBLED MONOLAYERS; DISEASE TOXIC GLIADIN; CELIAC-DISEASE; AMPEROMETRIC IMMUNOSENSOR; TISSUE TRANSGLUTAMINASE; AUTOANTIBODIES; BIOSENSOR; ELECTRODES; IGG; SCAFFOLDS;
D O I
10.1016/j.bios.2011.05.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The determination of antigliadin antibodies from human serum samples is of vital importance for the diagnosis of an autoimmune disease such as celiac disease. An electrochemical immunosensor that mimics traditional ELISA type architecture has been constructed for the detection of antigliadin antibodies with control over the orientation and packing of gliadin antigen molecules on the surface of gold electrodes. The orientation of the antigen on the surface has been achieved using a carboxylic-ended bipodal alkanethiol that is covalently linked with amino groups of the antigen protein. The bipodal thiol presents a long poly(ethyleneglycol)-modified chain that acts as an excellent non-specific adsorption barrier. The bipodal nature of the thiol ensured a good spacing and hence good diffusion properties of electroactive species through the self-assembled monolayer, which is vital for the efficiency of the constructed electrochemical immunosensor. The electrochemical immunosensor was characterized using surface plasmon resonance as well as electrochemical impedance spectroscopy. Amperometric evaluation of the sensor with polyclonal antigliadin antibodies showed stable and reproducible low limits of detection (46 ng/mL; % RSD = 8.2, n = 5). The behaviour and performance of the electrochemical immunosensor with more complex matrixes such as reference serum solutions and real patient samples was evaluated and compared with commercial ELISA kits demonstrating an excellent degree of correlation in thirty minutes total assay time; the electrochemical immunosensor not only delivers a positive or negative result, it allows the estimation of semi-quantitative antibody contents based on the comparison against clinical reference solutions. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4471 / 4476
页数:6
相关论文
共 50 条
[31]   Development of an immunosensor for the detection of Francisella tularensis antibodies [J].
Samuel B. Dulay ;
Sandra Julich ;
Herbert Tomaso ;
Ciara K. O’Sullivan .
Analytical and Bioanalytical Chemistry, 2014, 406 :4685-4690
[32]   A piezoelectric immunosensor for Leishmania chagasi antibodies in canine serum [J].
Ramos-Jesus, Joilson ;
Carvalho, Kellyanne A. ;
Fonseca, Rosana A. S. ;
Oliveira, Geraldo G. S. ;
Barrouin Melo, Stella M. ;
Alcantara-Neves, Neuza M. ;
Dutra, Rosa F. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (03) :917-925
[33]   Biosynthesized rGO@ZnO-based ultrasensitive electrochemical immunosensor for bovine serum albumin detection [J].
Garg, Palak ;
Thakur, Deeksha ;
Verma, Sakshi ;
Jalil, Owais ;
Pandey, Chandra Mouli ;
Kumar, Devendra .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 2023, 53 (07) :1449-1459
[34]   A disposable and ultrasensitive immunosensor for the detection of HE4 in human serum samples [J].
Vural, Berfin ;
Caliskan, Meltem ;
Bilgi Kamac, Melike ;
Sezginturk, Mustafa Kemal .
CHEMICAL PAPERS, 2024, 78 (05) :3331-3342
[35]   Biosynthesized rGO@ZnO-based ultrasensitive electrochemical immunosensor for bovine serum albumin detection [J].
Palak Garg ;
Deeksha Thakur ;
Sakshi Verma ;
Owais Jalil ;
Chandra Mouli Pandey ;
Devendra Kumar .
Journal of Applied Electrochemistry, 2023, 53 :1449-1459
[36]   Diagnosis of viral infectious diseases through sensitive detection of human serum antibodies using a modified label-free electrochemical biosensor [J].
Andrade, Tatianny de Araujo ;
Ribeiro, Iare Soares ;
Silva, Tiago Almeida ;
de Souza, Leyllanne Katharinne Araujo ;
Coltro, Wendell Karlos Tomazelli ;
Borges, Lysandro Pinto ;
Silva, Deise Maria Rego Rodrigues ;
Garcia, Paulo de Tarso ;
de Jesus, Jemmyson Romario .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (28) :6345-6355
[37]   SERUM IGA ANTIGLIADIN ANTIBODIES IN AN ADULT-POPULATION SAMPLE - HIGH PREVALENCE WITHOUT CELIAC-DISEASE [J].
UIBO, O ;
UIBO, R ;
KLEIMOLA, V ;
JOGI, T ;
MAKI, M .
DIGESTIVE DISEASES AND SCIENCES, 1993, 38 (11) :2034-2037
[38]   Electrochemical Development of an Immunosensor for Detection Polychlorinated biphenyls (PCBs) for Environmental Analysis [J].
Alsefri, Samia ;
Balbaied, Thanih ;
Moore, Eric .
CHEMOSENSORS, 2021, 9 (11)
[39]   Amperometric immunosensor for the determination of IgA deficiency in human serum samples [J].
Carlos Rosales-Rivera, Luis ;
Lluis Acero-Sanchez, Josep ;
Lozano-Sanchez, Pablo ;
Katakis, Ioanis ;
O'Sullivan, Ciara K. .
BIOSENSORS & BIOELECTRONICS, 2012, 33 (01) :134-138
[40]   DEVELOPMENT OF ELISA-BASED ASSAYS FOR DETECTION, QUANTITATION AND AVIDITY DETERMINATION OF SALIVARY IGA ANTIGLIADIN ANTIBODIES [J].
MILETIC, ID ;
SCHIFFMANN, SS ;
SATTELYMILLER, EA ;
MILETIC, VD .
JUGOSLOVENSKA MEDICINSKA BIOHEMIJA-YUGOSLAV MEDICAL BIOCHEMISTRY, 1995, 14 (1-2) :15-25