Electrochemical immunosensor detection of antigliadin antibodies from real human serum

被引:34
|
作者
Rosales-Rivera, L. C. [1 ]
Acero-Sanchez, J. L. [1 ]
Lozano-Sanchez, P. [1 ]
Katakis, I. [1 ]
O'Sullivan, C. K. [1 ,2 ]
机构
[1] Univ Rovira & Virgili, Dept Engn Quim, Tarragona 43007, Spain
[2] Inst Catalano Recerca & Estudis Avancats, Barcelona 08010, Spain
来源
BIOSENSORS & BIOELECTRONICS | 2011年 / 26卷 / 11期
关键词
Electrochemical immunosensors; Self assembled monolayer (SAM); Antigliadin antibodies; Celiac disease; SELF-ASSEMBLED MONOLAYERS; DISEASE TOXIC GLIADIN; CELIAC-DISEASE; AMPEROMETRIC IMMUNOSENSOR; TISSUE TRANSGLUTAMINASE; AUTOANTIBODIES; BIOSENSOR; ELECTRODES; IGG; SCAFFOLDS;
D O I
10.1016/j.bios.2011.05.004
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The determination of antigliadin antibodies from human serum samples is of vital importance for the diagnosis of an autoimmune disease such as celiac disease. An electrochemical immunosensor that mimics traditional ELISA type architecture has been constructed for the detection of antigliadin antibodies with control over the orientation and packing of gliadin antigen molecules on the surface of gold electrodes. The orientation of the antigen on the surface has been achieved using a carboxylic-ended bipodal alkanethiol that is covalently linked with amino groups of the antigen protein. The bipodal thiol presents a long poly(ethyleneglycol)-modified chain that acts as an excellent non-specific adsorption barrier. The bipodal nature of the thiol ensured a good spacing and hence good diffusion properties of electroactive species through the self-assembled monolayer, which is vital for the efficiency of the constructed electrochemical immunosensor. The electrochemical immunosensor was characterized using surface plasmon resonance as well as electrochemical impedance spectroscopy. Amperometric evaluation of the sensor with polyclonal antigliadin antibodies showed stable and reproducible low limits of detection (46 ng/mL; % RSD = 8.2, n = 5). The behaviour and performance of the electrochemical immunosensor with more complex matrixes such as reference serum solutions and real patient samples was evaluated and compared with commercial ELISA kits demonstrating an excellent degree of correlation in thirty minutes total assay time; the electrochemical immunosensor not only delivers a positive or negative result, it allows the estimation of semi-quantitative antibody contents based on the comparison against clinical reference solutions. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:4471 / 4476
页数:6
相关论文
共 50 条
  • [1] Electrochemical detection of celiac disease-related anti-tissue transglutaminase antibodies using thiol based surface chemistry
    Dulay, Samuel
    Lozano-Sanchez, Pablo
    Iwuoha, Emmanuel
    Katakis, Ioanis
    O'Sullivan, Ciara K.
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (09): : 3852 - 3856
  • [2] Multiplexed electrochemical immunosensor for detection of celiac disease serological markers
    Neves, Marta M. P. S.
    Begona Gonzalez-Garcia, Maria
    Delerue-Matos, Cristina
    Costa-Garcia, Agustin
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 187 : 33 - 39
  • [3] SERUM IGA ANTIGLIADIN ANTIBODIES FOR DETECTION AND FOLLOW-UP OF ADULT CELIAC-DISEASE
    PICAZO, MRI
    ALONSO, IJ
    REY, MAM
    GOMEZ, SR
    ALONSO, JS
    SANCHEZ, CV
    GARCIA, JMP
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 1992, 81 (01) : 15 - 18
  • [4] Label-free electrochemical impedimetric immunosensor for sensitive detection of IgM rheumatoid factor in human serum
    Chinnadayyala, Somasekhar R.
    Park, Jinsoo
    Abbasi, Muhammad A.
    Choa, Sungbo
    BIOSENSORS & BIOELECTRONICS, 2019, 143
  • [5] SALIVARY AND SERUM IGA ANTIGLIADIN ANTIBODIES IN DERMATITIS-HERPETIFORMIS
    PATINEN, P
    BJORKSTEN, F
    MALMSTROM, M
    SAVILAHTI, E
    REUNALA, T
    EUROPEAN JOURNAL OF ORAL SCIENCES, 1995, 103 (05) : 280 - 284
  • [6] ADHERENCE TO GLUTEN-FREE DIET AND SERUM ANTIGLIADIN ANTIBODIES IN CELIAC-DISEASE
    VALLETTA, EA
    MASTELLA, G
    DIGESTION, 1990, 47 (01) : 20 - 23
  • [7] Nanogold hollow microsphere-based electrochemical immunosensor for the detection of ferritin in human serum
    Wang, Xiuling
    Tao, Guanhong
    Meng, Yuanhua
    MICROCHIMICA ACTA, 2009, 167 (1-2) : 147 - 152
  • [8] Positive serum antigliadin antibodies without celiac disease in the elderly population: does it matter?
    Ruuskanen, Anitta
    Kaukinen, Katri
    Collin, Pekka
    Huhtala, Heini
    Valve, Raisa
    Maki, Markku
    Luostarinen, Liisa
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 2010, 45 (10) : 1197 - 1202
  • [9] Electrochemical immunosensor for highly sensitive and quantitative detection of tumor necrosis factor-α in human serum
    Yagati, Ajay Kumar
    Lee, Min-Ho
    Min, Junhong
    BIOELECTROCHEMISTRY, 2018, 122 : 93 - 102
  • [10] Electrochemical immunosensor for detection of antibodies against influenza A virus H5N1 in hen serum
    Jarocka, Urszula
    Sawicka, Roza
    Gora-Sochacka, Anna
    Sirko, Agnieszka
    Zagorski-Ostoja, Wlodzimierz
    Radecki, Jerzy
    Radecka, Hanna
    BIOSENSORS & BIOELECTRONICS, 2014, 55 : 301 - 306