Comparison of moisture buffering properties of plasters in full scale simulations and laboratory testing

被引:18
|
作者
Cascione, Valeria [1 ]
Maskell, Daniel [1 ]
Shea, Andy [1 ]
Walker, Pete [1 ]
Mani, Monto [2 ]
机构
[1] Univ Bath, BRE Ctr Innovat Construct Mat, Dept Architecture & Civil Engn, Bath, Avon, England
[2] IISc, SuDesi Lab, Ctr Sustainable Technol, Bengaluru, India
基金
英国工程与自然科学研究理事会;
关键词
Materials; Dynamic sorption capacity; Hygrothermal performance; Ventilation; Moisture transfer; RELATIVE-HUMIDITY; GYPSUM BOARD; INDOOR; PERFORMANCE; ADSORPTION; CAPACITY;
D O I
10.1016/j.conbuildmat.2020.119033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The regulation of indoor relative humidity is a key factor for the provision of occupant health and comfort. Passive humidity regulation is possible if porous materials, for example clay and gypsum plasters, are exposed to the indoor environment. Materials that are highly hygroscopic can help regulate relative humidity levels through their capacity to adsorb and release water vapour from and to the indoor air via a dynamic process referred to as moisture buffering. Laboratory test methods have been developed to measure this moisture buffering capacity, which are well-suited for comparative testing of relatively small material samples under controlled conditions. However, quantification of the impact of hygroscopic materials in real buildings requires additional evaluation, like field testing and the support of simulation models, which can successively be used for the development of new protocols capable of giving information about materials' moisture buffering performances indoors. This paper investigates moisture buffering capacity of three hygroscopic plasters (clay, gypsum and lime), and compares measurements obtained in the laboratory to those from numerical simulations of a single-zone room space. The dynamic sorption capacity of the plasters was investigated using the NORDTEST protocol and results compared to those from hygrothermal simulation. Differences are identified between the two methods in the quantification of the moisture buffering potential, which lead to further investigation on the effect of ventilation and moisture transport through the entire wall assembly. The significance of this paper is to show building moisture regulation involves also different factors, such as ventilation and walls moisture transport, which will impact the moisture buffering potentials indoors. Consequently, it is necessary to better understand moisture buffering in real buildings, to quantify the influence of hygroscopic materials indoors, and introduce alternative laboratory testing, to give quantitative information about their impact in buildings. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 9 条
  • [1] A review of moisture buffering capacity: From laboratory testing to full-scale measurement
    Cascione, Valeria
    Maskell, Daniel
    Shea, Andy
    Walker, Pete
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 200 : 333 - 343
  • [2] Removal efficiency of storm water treatment techniques: standardized full scale laboratory testing
    Boogaard, F. C.
    van de Ven, F.
    Langeveld, J. G.
    Kluck, J.
    van de Giesen, N.
    URBAN WATER JOURNAL, 2017, 14 (03) : 255 - 262
  • [3] EMPD-based moisture buffering quantification with moisture-dependent properties (CYRILLIC CAPITAL LETTER BYELORUSSIAN-UKRAINIAN I): Modelling and simulations
    Cui, Yumeng
    Zhang, Yufeng
    Janssen, Hans
    BUILDING AND ENVIRONMENT, 2021, 205
  • [4] A study on drum cutting properties with full-scale experiments and numerical simulations
    Li, Xuefeng
    Wang, Shibo
    Ge, Shirong
    Malekian, Reza
    Li, Zhixiong
    Li, Yifei
    MEASUREMENT, 2018, 114 : 25 - 36
  • [5] Unsteady RANS CFD Simulations of Sailboat's Hull and Comparison with Full-Scale Test
    Casalone, Pietro
    Dell'Edera, Oronzo
    Fenu, Beatrice
    Giorgi, Giuseppe
    Sirigu, Sergej Antonello
    Mattiazzo, Giuliana
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2020, 8 (06)
  • [6] A study on pick cutting properties with full-scale rotary cutting experiments and numerical simulations
    Zhang, Qianqian
    Fan, Qiuxia
    Gao, Hongbin
    Wu, Yulong
    Xu, Fujing
    PLOS ONE, 2022, 17 (04):
  • [7] Hygrothermal assessment of internal insulation systems of brick walls through numerical simulation and full-scale laboratory testing
    De Mets, Timo
    Tilmans, Antoine
    Loncour, Xavier
    11TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB2017), 2017, 132 : 753 - 758
  • [8] Furnace Testing of Full-Scale Gypsum Steel Stud Non-Load Bearing Wall Assemblies: Results of Multi-Laboratory Testing in Canada, Japan, and USA
    Manzello, Samuel L.
    Grosshandler, William L.
    Mizukami, Tensei
    FIRE TECHNOLOGY, 2010, 46 (01) : 183 - 200
  • [9] Comparison of soluble microbial product (SMP) production in full-scale anaerobic/aerobic industrial wastewater treatment and a laboratory based synthetic feed anaerobic membrane system
    Soh, Yan Ni Annie
    Kunacheva, Chinagarn
    Menon, Suren
    Webster, Richard D.
    Stuckey, David C.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 754