Scanning orientation and polarization effects for XRQA radiochromic film

被引:29
作者
Alnawaf, Hani [3 ]
Butson, Martin J. [1 ,2 ,3 ]
Cheung, Tsang [2 ]
Yu, Peter K. N. [2 ]
机构
[1] Illawarra Canc Care Ctr, Dept Med Phys, Wollongong, NSW 2500, Australia
[2] City Univ Hong Kong, Dept Phys & Mat Sci, Kowloon Tong, Hong Kong, Peoples R China
[3] Univ Wollongong, Ctr Med Radiat Phys, Gwynneville, NSW, Australia
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2010年 / 26卷 / 04期
关键词
Gafchromic XRQA; Radiochromic film; Densitometry; Orientation; ENERGY-DEPENDENCE; QA FILM; X-RAY; DOSIMETRY;
D O I
10.1016/j.ejmp.2010.01.003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gafchromic XRQA radiochromic film, is an effective tool for quality assurance and dose assessment in kilovoltage radiotherapy and diagnostic applications. Like other Gafchromic film products, XRQA film exhibits a variation in dose to reflected optical density response with angle of rotation when analysed with a light source that is partially or fully polarised such as a desktop scanner. Although warnings are not given on manufacturers specifications, this can affect dosimetry accuracy and we recommend that it is essential to scan all XRQA films in the same orientation. The effect is not as pronounced as EBT Gafchromic film. The magnitude of this variation has been measured and shown to be up to 16 +/- 2% (1SD) using a fully linear polarised light source was seen with a 90 degrees angle rotation. This would be the maximum variation seen on a desktop scanner with a fully polarised light source. For our standard desktop scanner (Epson v700) a mean variation of 2 +/- 1% from 0 cGy to 20 cGy applied dose was measured as compared to 8 +/- 2% for EBT Gafchromic. We recommend that to decrease uncertainty in dose measurement, accurate alignment of the calibration films to experimental films be performed on a regular basis. This is especially important if your desktop scanner has a high degree of polarization of its light source. (C) 2010 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:216 / 219
页数:4
相关论文
共 15 条
[1]   Absorption spectra response of XRQA radiochromic film to x-ray radiation [J].
Alnawaf, Hani ;
Cheung, Tsang ;
Butson, Martin J. ;
Yu, Peter K. N. .
RADIATION MEASUREMENTS, 2010, 45 (01) :129-132
[2]   Scanning orientation effects on Gafchromic EBT film dosimetry [J].
Butson M.J. ;
Cheung T. ;
Yu P.K.N. .
Australasian Physical and Engineering Sciences in Medicine, 2006, 29 (03) :281-284
[3]   Evaluation of the magnitude of EBT Gafchromic film polarization effects [J].
Butson, M. J. ;
Cheung, T. ;
Yu, P. K. N. .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2009, 32 (01) :21-25
[4]   Post-irradiation colouration of Gafchromic EBT radiochromic film [J].
Cheung, T ;
Butson, MJ ;
Yu, PKN .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20) :N281-N285
[5]   Energy dependence of response of new high sensitivity radiochromic films for megavoltage and kilovoltage radiation energies [J].
Chiu-Tsao, ST ;
Ho, Y ;
Shankar, R ;
Wang, L ;
Harrison, LB .
MEDICAL PHYSICS, 2005, 32 (11) :3350-3354
[6]   GafChromic XR-QA film in testing panoramic dental radiography [J].
Chu, Robert Y. L. ;
Lam, Tin ;
Liang, Yongguang .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02) :110-113
[7]   A SOLID WATER PHANTOM MATERIAL FOR RADIOTHERAPY X-RAY AND GAMMA-RAY BEAM CALIBRATIONS [J].
CONSTANTINOU, C ;
ATTIX, FH ;
PALIWAL, BR .
MEDICAL PHYSICS, 1982, 9 (03) :436-441
[8]   Dosimetric evaluation of GAFCHROMIC® XR type T and XR type R films [J].
Dini, Sharifeh A. ;
Koona, Rafiq A. ;
Ashburn, John R. ;
Meigooni, Ali S. .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (01) :114-134
[9]   Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMIC® film [J].
Lynch, Bart D. ;
Kozelka, Jakub ;
Ranade, Manisha K. ;
Li, Jonathan G. ;
Simon, William E. ;
Dempsey, James F. .
MEDICAL PHYSICS, 2006, 33 (12) :4551-4556
[10]   High sensitivity radiochromic film dosimetry using an optical common-mode rejection and a reflective-mode flatbed color scanner [J].
Ohuchi, Hiroko .
MEDICAL PHYSICS, 2007, 34 (11) :4207-4212