Sensitive and rapid simultaneous quantitation of leucovorin and its major active metabolite 5-methyl-tetrahydrofolate in human plasma using a liquid chromatography coupled with triple quadruple mass spectrometry

被引:4
作者
Dubey, Naveen Kr [1 ]
机构
[1] Jubilant Gener Ltd, Noida 201307, UP, India
关键词
bioequivalence; human plasma; LC-MS; MS; leucovorin; ACID;
D O I
10.1002/bmc.5299
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Bioanalysis of an endogenous compound such as leucovorin is never an easy task on a liquid chromatography tandem mass spectrometer (LC-MSMS). Unless it is necessary, regulatory guidance discourages working with surrogate matrices for calibration curve standard preparation. Herein, a selective and sensitive liquid chromatography-tandem mass spectrometry method for simultaneous determination of leucovorin and 5-methyl tetrahydrofolic acid in human plasma was developed and validated. Stable labeled internal standards, i.e. leucovorin D-4 and 5- methyl tetrahydrofolic acid C-13(5), were used as internal standards to track and compensate the parent compounds during processing and extraction from plasma. The method involves a rapid solid-phase extraction from plasma followed by reverse-phase gradient chromatography and mass spectrometry detection with a total run time of 5 min. The method was developed and validated from 5 to 2,202 ng/ml for leucovorin and from 5 to 1,300 ng/ml for 5-methyl tetrahydrofolic acid. The mean recoveries for leucovorin and 5-methyl tetrahydrofolic acid were 100.4 and 100.9% respectively. The validated method enabled the simultaneous analysis of leucovorin and 5-methyl tetrahydrofolic acid in samples from clinical pharmacokinetic studies of leucovorin. The peak concentrations of leucovorin and 5-methyl tetrahydrofolic acid were 651-883 and 518-635 ng/ml, respectively, in fasted and fed conditions. The terminal half-life values for leucovorin and 5-methyl tetrahydrofolic acid were 9.3-10.5 and 9.2-17.6 h, respectively.
引用
收藏
页数:12
相关论文
共 25 条
[1]  
Center for Drug Evaluation and Research, 2007, PHARM REV
[2]  
Center for Drug Evaluation and Research, 2016, SUMM REV APPL NO 208
[3]  
DailyMed, 2018, LEUC CALC LEUC CALC
[4]  
Damle B, 2001, CLIN CANCER RES, V7, P517
[5]   High-performance liquid chromatographic method for determination of leucovorin in plasma: validation and application to a pharmacokinetic study in healthy volunteers [J].
Duan, GL ;
Zheng, LX ;
Chen, J ;
Cheng, WB ;
Li, D .
BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (04) :282-286
[6]  
FDA-BMW, 2018, BIOAN METH VAL GUID
[7]   Incurred sample reanalysis in drug discovery bioanalysis [J].
Giri, Poonam ;
Patel, Nirmal ;
Joshi, Vipul ;
Giri, Shyamkumar ;
Srinivas, Nuggehally R. .
BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (03)
[8]  
Hassan N., 2011, IRAN J KIDNEY DIS, V5, P45
[9]  
Jemal M, 1999, RAPID COMMUN MASS SP, V13, P1003, DOI 10.1002/(SICI)1097-0231(19990615)13:11<1003::AID-RCM597>3.0.CO
[10]  
2-L