Higher-order regression three-dimensional motion-compensation method for real-time optical coherence tomography volumetric imaging of the cornea

被引:2
作者
Zuo, Ruizhi [1 ]
Irsch, Kristina [2 ,3 ]
Kang, Jin U. [1 ,3 ]
机构
[1] Johns Hopkins Univ, Whiting Sch Engn, Baltimore, MD 21218 USA
[2] CNRS, Vis Inst, Paris, France
[3] Johns Hopkins Univ, Sch Med, Baltimore, MD USA
基金
欧洲研究理事会;
关键词
optical coherence tomography; motion compensation; real-time; cornea; volumetric imaging;
D O I
10.1117/1.JBO.27.6.066006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Optical coherence tomography (OCT) allows high-resolution volumetric three-dimensional (3D) imaging of biological tissues in vivo. However, 3D-image acquisition can be time-consuming and often suffers from motion artifacts due to involuntary and physiological movements of the tissue, limiting the reproducibility of quantitative measurements. Aim: To achieve real-time 3D motion compensation for corneal tissue with high accuracy. Approach: We propose an OCT system for volumetric imaging of the cornea, capable of compensating both axial and lateral motion with micron-scale accuracy and millisecond-scale time consumption based on higher-order regression. Specifically, the system first scans three reference B-mode images along the C-axis before acquiring a standard C-mode image. The difference between the reference and volumetric images is compared using a surface-detection algorithm and higher-order polynomials to deduce 3D motion and remove motion-related artifacts. Results: System parameters are optimized, and performance is evaluated using both phantom and corneal (ex vivo) samples. An overall motion-artifact error of <4.61 microns and processing time of about 3.40 ms for each B-scan was achieved. Conclusions: Higher-order regression achieved effective and real-time compensation of 3D motion artifacts during corneal imaging. The approach can be expanded to 3D imaging of other ocular tissues. Implementing such motion-compensation strategies has the potential to improve the reliability of objective and quantitative information that can be extracted from volumetric OCT measurements. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License.
引用
收藏
页数:19
相关论文
共 32 条
  • [1] Microsaccade Characteristics in Neurological and Ophthalmic Disease
    Alexander, Robert G.
    Macknik, Stephen L.
    Martinez-Conde, Susana
    [J]. FRONTIERS IN NEUROLOGY, 2018, 9
  • [2] Bradley Derek, 2007, Journal of Graphics Tools, V12, P13
  • [3] Review on Retrospective Procedures to Correct Retinal Motion Artefacts in OCT Imaging
    Brea, Luisa Sanchez
    De Jesus, Danilo Andrade
    Shirazi, Muhammad Faizan
    Pircher, Michael
    van Walsum, Theo
    Klein, Stefan
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (13):
  • [4] Three-dimensional eye motion correction by Lissajous scan optical coherence tomography
    Chen, Yiwei
    Hong, Young-Joo
    Makita, Shuichi
    Yasuno, Yoshiaki
    [J]. BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03): : 1783 - 1802
  • [5] Motorized Microforceps With Active Motion Guidance Based on Common-Path SSOCT for Epiretinal Membranectomy
    Cheon, Gyeong Woo
    Gonenc, Berk
    Taylor, Russell H.
    Gehlbach, Peter L.
    Kang, Jin U.
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2017, 22 (06) : 2440 - 2448
  • [6] Heartbeat-Induced Axial Motion Artifacts in Optical Coherence Tomography Measurements of the Retina
    de Kinkelder, Roy
    Kalkman, Jeroen
    Faber, Dirk J.
    Schraa, Olaf
    Kok, Pauline H. B.
    Verbraak, Frank D.
    van Leeuwen, Ton G.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (06) : 3908 - 3913
  • [7] The Development, Commercialization, and Impact of Optical Coherence Tomography
    Fujimoto, James
    Swanson, Eric
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT1 - OCT13
  • [8] Estimation in Gaussian Noise: Properties of the Minimum Mean-Square Error
    Guo, Dongning
    Wu, Yihong
    Shamai , Shlomo
    Verdu, Sergio
    [J]. IEEE TRANSACTIONS ON INFORMATION THEORY, 2011, 57 (04) : 2371 - 2385
  • [9] Demonstration of Optical Coherence Tomography Guided Big Bubble Technique for Deep Anterior Lamellar Keratoplasty (DALK)
    Guo, Shoujing
    Sarfaraz, Nicolas R.
    Gensheimer, William G.
    Krieger, Axel
    Kang, Jin U.
    [J]. SENSORS, 2020, 20 (02)
  • [10] OPTICAL COHERENCE TOMOGRAPHY
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    STINSON, WG
    CHANG, W
    HEE, MR
    FLOTTE, T
    GREGORY, K
    PULIAFITO, CA
    FUJIMOTO, JG
    [J]. SCIENCE, 1991, 254 (5035) : 1178 - 1181