Label-free screening of bio-molecular interactions

被引:355
作者
Cooper, MA [1 ]
机构
[1] Univ Cambridge, Chem Lab, Cambridge Ctr Mol Recognit, Cambridge CB2 1EW, England
关键词
biosensor; screening; label-free; review; acoustic; surface plasmon resonance; quartz crystal microbalance; calorimetry;
D O I
10.1007/s00216-003-2111-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The majority of techniques currently employed to interrogate a biomolecular interaction require some type of radio- or enzymatic- or fluorescent-labelling to report the binding event. However, there is an increasing awareness of novel techniques that do not require labelling of the ligand or the receptor, and that allow virtually any complex to be screened with minimal assay development. This review focuses on three major label-free screening platforms: surface plasmon resonance biosensors, acoustic biosensors, and calorimetric biosensors. Scientists in both academia and industry are using biosensors in areas that encompass almost all areas drug discovery, diagnostics, and the life sciences. The capabilities and advantages of each technique are compared and key applications involving small molecules, proteins, oligonucleotides, bacteriophage, viruses, bacteria, and cells are reviewed. The role of the interface between the biosensor surface ( in the case of SPR and acoustic biosensors) and the chemical or biological systems to be studied is also covered with attention to the covalent and non-covalent coupling chemistries commonly employed.
引用
收藏
页码:834 / 842
页数:9
相关论文
共 120 条
  • [71] REAL-TIME MONITORING OF DNA MANIPULATIONS USING BIOSENSOR TECHNOLOGY
    NILSSON, P
    PERSSON, B
    UHLEN, M
    NYGREN, PA
    [J]. ANALYTICAL BIOCHEMISTRY, 1995, 224 (01) : 400 - 408
  • [72] FREQUENCY-SHIFTS OF PIEZOELECTRIC QUARTZ CRYSTALS IMMERSED IN ORGANIC LIQUIDS
    NOMURA, T
    OKUHARA, M
    [J]. ANALYTICA CHIMICA ACTA, 1982, 142 (OCT) : 281 - 284
  • [73] DETECTION AND QUANTITATION OF HEXA-HISTIDINE-TAGGED RECOMBINANT PROTEINS ON WESTERN BLOTS AND BY A SURFACE-PLASMON RESONANCE BIOSENSOR TECHNIQUE
    OSHANNESSY, DJ
    ODONNELL, KC
    MARTIN, J
    BRIGHAMBURKE, M
    [J]. ANALYTICAL BIOCHEMISTRY, 1995, 229 (01) : 119 - 124
  • [74] Effect of ionic strength on initial interactions of Escherichia coli with surfaces, studied on-line by a novel quartz crystal microbalance technique
    Otto, K
    Elwing, H
    Hermansson, M
    [J]. JOURNAL OF BACTERIOLOGY, 1999, 181 (17) : 5210 - 5218
  • [75] A rapid, non-destructive method for the determination of Staphylococcus epidermidis adhesion to surfaces using quartz crystal resonant sensor technology
    Pavey, KD
    Barnes, LM
    Hanlon, GW
    Olliff, CJ
    Ali, Z
    Paul, F
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2001, 33 (05) : 344 - 348
  • [76] Vitamin C induced decomposition of lipid hydroperoxides: direct evidence of genotoxin-DNA binding detected by QCRS
    Pavey, KD
    Miah, M
    Fucassi, F
    Paul, F
    Cragg, PJ
    [J]. CHEMICAL COMMUNICATIONS, 2001, (18) : 1886 - 1887
  • [77] Quartz crystal resonant sensor (QCRS) model for label-free, small molecules - receptor studies
    Pavey, KD
    Olliff, CJ
    Paul, F
    [J]. ANALYST, 2001, 126 (10) : 1711 - 1715
  • [78] Application of the quartz crystal microbalance to the monitoring of Staphylococcus epidermidis antigen-antibody agglutination
    Pavey, KD
    Ali, Z
    Olliff, CJ
    Paul, F
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 20 (1-2) : 241 - 245
  • [79] Molecular imprinted polymer coated QCM for the detection of nandrolone
    Percival, CJ
    Stanley, S
    Braithwaite, A
    Newton, MI
    McHale, G
    [J]. ANALYST, 2002, 127 (08) : 1024 - 1026
  • [80] Probing DNA duplex formation and DNA-drug interactions by the quartz crystal microbalance technique
    Pope, LH
    Allen, S
    Davies, MC
    Roberts, CJ
    Tendler, SJB
    Williams, PM
    [J]. LANGMUIR, 2001, 17 (26) : 8300 - 8304