High-Throughput Quantitation of Neonicotinoids in Lyophilized Surface Water by LC-APCI-MS/MS

被引:12
作者
Morrison, Lucas M. [1 ,2 ]
Renaud, Justin B. [1 ]
Sabourin, Lyne [1 ]
Sumarah, Mark W. [1 ,2 ]
Yeung, Ken K. C. [2 ,3 ]
Lapen, David R. [4 ]
机构
[1] Agr & Agri Food Canada, London Res & Dev Ctr, London, ON N5V 4T3, Canada
[2] Univ Western Ontario, Dept Chem, London, ON N6A 5B7, Canada
[3] Univ Western Ontario, Dept Biochem, London, ON N6A 5C1, Canada
[4] Agr & Agri Food Canada, Ottawa Res & Dev Ctr, Ottawa, ON K1A 0C6, Canada
关键词
MASS-SPECTROMETRY ANALYSIS; LIQUID-CHROMATOGRAPHY; DRINKING-WATER; INSECTICIDES; EXTRACTION; PESTICIDES; ANTIBIOTICS; RESIDUES; FATE; MS;
D O I
10.5740/jaoacint.17-0486
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Neonicotinoids are among the most widely used insecticides. Recently, there has been concern associated with unintended adverse effects on honeybees and aquatic invertebrates at low parts-per-trillion levels. Objective: There is a need for LC-MS/MS methods that are capable of high-throughput measurements of the most widely used neonicotinoids at environmentally relevant concentrations in surface water. Methods: This method allows for quantitation of acetamiprid, clothianidin, imidacloprid, dinotefuran, nitenpyram, thiacloprid, and thiamethoxam in surface water. Deuterated internal standards are added to 20 mL environmental samples, which are concentrated by lyophilisation and reconstituted with methanol followed by acetonitrile. Results: A large variation of mean recovery efficiencies across five different surface water sampling sites within this study was observed, ranging from 45 to 74%. This demonstrated the need for labelled internal standards to compensate for these differences. Atmospheric pressure chemical ionization (APCI) performed better than electrospray ionization (ESI) with limited matrix suppression, achieving 71-110% of the laboratory fortified blank signal. Neonicotinoids were resolved on a C18 column using a 5 min LC method, in which MQL ranged between 0.93 and 4.88 ng/L. Conclusions: This method enables cost effective, accurate, and reproducible monitoring of these pesticides in the aquatic environment. Highlights: Lyophilization is used for high throughput concentration of neonicotinoids in surface water. Variations in matrix effects between samples was greatly reduced by using APCI compared with ESI. Clothianidin and thiamethoxam were detected in all samples with levels ranging from below method quantitation limit to 65 ng/L.
引用
收藏
页码:1940 / 1947
页数:8
相关论文
共 50 条
  • [21] Novel Approach to Optimization of a High-Throughput Semipreparative LC/MS System
    FitzGibbons, Julia
    Op, Sopheary
    Hobson, Adrian
    Schaffter, Lisa
    JOURNAL OF COMBINATORIAL CHEMISTRY, 2009, 11 (04): : 592 - 597
  • [22] Derivatization-based High-throughput Bioanalysis by LC-MS
    Toshimasa Toyo’Oka
    Analytical Sciences, 2017, 33 : 555 - 564
  • [23] Development of a fast isocratic LC-MS/MS method for the high-throughput analysis of pyrrolizidine alkaloids in Australian honey
    Griffin, Caroline T.
    Mitrovic, Simon M.
    Danaher, Martin
    Furey, Ambrose
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2015, 32 (02): : 214 - 228
  • [24] Determination of Patulin in Apple Juice and Apple-Derived Products Using a Robotic Sample Preparation System and LC-APCI-MS/MS
    Zhang, Kai
    Zhang, Lauren
    TOXINS, 2024, 16 (06)
  • [25] DBS direct elution: optimizing performance in high-throughput quantitative LC-MS/MS analysis
    Abu-Rabie, Paul
    Spooner, Neil
    Chowdhry, Babur Z.
    Pullen, Frank S.
    BIOANALYSIS, 2015, 7 (16) : 2003 - 2017
  • [26] High-Throughput Screening and Confirmation of 22 Banned Veterinary Drugs in Feedstuffs Using LC-MS/MS and High-Resolution Orbitrap Mass Spectrometry
    Wang, Xufeng
    Liu, Yanghong
    Su, Yijuan
    Yang, Jianwen
    Bian, Kui
    Wang, Zongnan
    He, Li-Min
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (02) : 516 - 527
  • [27] A sensitive, high-throughput LC-MS/MS method for measuring catecholamines in low volume serum
    Zheng, Jiamin
    Mandal, Rupasri
    Wishart, David S.
    ANALYTICA CHIMICA ACTA, 2018, 1037 : 159 - 167
  • [28] Development of rapid and high-throughput LC-MS/MS method for quantification of olprinone in rabbit plasma
    Kertys, Martin
    Kosutova, Petra
    Mokra, Daniela
    Mokry, Juraj
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (10)
  • [29] Automated sample preparation and LC-MS for high-throughput ADME quantification
    O'Connor, D
    CURRENT OPINION IN DRUG DISCOVERY & DEVELOPMENT, 2002, 5 (01) : 52 - 58
  • [30] High Throughput Quantitative Bioanalytical LC/MS/MS Determination of Gemifloxacin in Human Urine
    Kadi, Adnan A.
    Angawi, Rihab F.
    Attwa, Mohamed W.
    Darwish, Hany W.
    Abdelhameed, Ali Saber
    JOURNAL OF CHEMISTRY, 2013, 2013