High-Throughput Quantitation of Neonicotinoids in Lyophilized Surface Water by LC-APCI-MS/MS

被引:12
|
作者
Morrison, Lucas M. [1 ,2 ]
Renaud, Justin B. [1 ]
Sabourin, Lyne [1 ]
Sumarah, Mark W. [1 ,2 ]
Yeung, Ken K. C. [2 ,3 ]
Lapen, David R. [4 ]
机构
[1] Agr & Agri Food Canada, London Res & Dev Ctr, London, ON N5V 4T3, Canada
[2] Univ Western Ontario, Dept Chem, London, ON N6A 5B7, Canada
[3] Univ Western Ontario, Dept Biochem, London, ON N6A 5C1, Canada
[4] Agr & Agri Food Canada, Ottawa Res & Dev Ctr, Ottawa, ON K1A 0C6, Canada
关键词
MASS-SPECTROMETRY ANALYSIS; LIQUID-CHROMATOGRAPHY; DRINKING-WATER; INSECTICIDES; EXTRACTION; PESTICIDES; ANTIBIOTICS; RESIDUES; FATE; MS;
D O I
10.5740/jaoacint.17-0486
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Neonicotinoids are among the most widely used insecticides. Recently, there has been concern associated with unintended adverse effects on honeybees and aquatic invertebrates at low parts-per-trillion levels. Objective: There is a need for LC-MS/MS methods that are capable of high-throughput measurements of the most widely used neonicotinoids at environmentally relevant concentrations in surface water. Methods: This method allows for quantitation of acetamiprid, clothianidin, imidacloprid, dinotefuran, nitenpyram, thiacloprid, and thiamethoxam in surface water. Deuterated internal standards are added to 20 mL environmental samples, which are concentrated by lyophilisation and reconstituted with methanol followed by acetonitrile. Results: A large variation of mean recovery efficiencies across five different surface water sampling sites within this study was observed, ranging from 45 to 74%. This demonstrated the need for labelled internal standards to compensate for these differences. Atmospheric pressure chemical ionization (APCI) performed better than electrospray ionization (ESI) with limited matrix suppression, achieving 71-110% of the laboratory fortified blank signal. Neonicotinoids were resolved on a C18 column using a 5 min LC method, in which MQL ranged between 0.93 and 4.88 ng/L. Conclusions: This method enables cost effective, accurate, and reproducible monitoring of these pesticides in the aquatic environment. Highlights: Lyophilization is used for high throughput concentration of neonicotinoids in surface water. Variations in matrix effects between samples was greatly reduced by using APCI compared with ESI. Clothianidin and thiamethoxam were detected in all samples with levels ranging from below method quantitation limit to 65 ng/L.
引用
收藏
页码:1940 / 1947
页数:8
相关论文
共 50 条
  • [1] Determination of cypermethrin in salmon by LC-APCI-MS
    Sorensen, LK
    Hansen, H
    ANALYTICAL LETTERS, 2003, 36 (01) : 191 - 201
  • [2] LC-APCI-MS/MS Quantification and Topical Bioavailability of Chloroacetamide in Rats
    Kim, Tae Hwan
    Seok, Su Hyun
    Kim, Kyu-Bong
    Shin, Beom Soo
    Lee, Jeong Pyo
    Choi, Yong-Kyu
    Kim, Min Gi
    Kim, Min Kyu
    Kim, Sang Min
    Yoo, Sun Dong
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2015, 53 (07) : 1100 - 1106
  • [3] Methods for the analysis of organophosphorus flame retardantsComparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS
    Tokumura, Masahiro
    Miyake, Yuichi
    Wang, Qi
    Nakayama, Hayato
    Amagai, Takashi
    Ogo, Sayaka
    Kume, Kazunari
    Kobayashi, Takeshi
    Takasu, Shinji
    Ogawa, Kumiko
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2018, 53 (05): : 475 - 481
  • [4] Evaluation of a Modified QuEChERS Extraction of Multiple Classes of Pesticides from a Rice Paddy Soil by LC-APCI-MS/MS
    Caldas, Sergiane S.
    Bolzan, Catia M.
    Cerqueira, Maristela B.
    Tomasini, Debora
    Furlong, Eliana B.
    Fagundes, Carlos
    Primel, Ednei G.
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2011, 59 (22) : 11918 - 11926
  • [5] On-Line SPE Coupled with LC-APCI-MS for the Determination of Trace Explosives in Water
    Sun, Qian
    Chen, Zuliang
    Yuan, Dongxing
    Yu, Chang-Ping
    Mallavarapu, Megharaj
    Naidu, Ravendra
    CHROMATOGRAPHIA, 2011, 73 (7-8) : 631 - 637
  • [6] Determination of endogenous corticosterone in rodent's blood, brain and hair with LC-APCI-MS/MS
    Yu, Tian
    Xu, Hang
    Wang, Weiwen
    Li, Shifei
    Chen, Zheng
    Deng, Huihua
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 1002 : 267 - 276
  • [7] Neonicotinoids Detection by new LC-MS/MS Method in Romanian Surface Waters
    Iancu, Vasile Ion
    Galaon, Toma
    Niculescu, Marcela
    Lehr, Carol Blaziu
    REVISTA DE CHIMIE, 2017, 68 (08): : 1716 - 1722
  • [8] Development and validation of an LC-APCI-MS/MS method for the determination of phenethyl isothiocyanate in human plasma
    Zheng, Li
    Zheng, Feng
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (04) : 619 - 625
  • [9] LC-APCI-MS/MS assay for quantitation of ethyl esters of eicosapentaenoic acid and docosahexaenoic acid in human plasma and its application in a pharmacokinetic study
    Li, Le
    Xia, Ying
    Zhao, Shunbo
    Ding, Li
    Ji, Shunli
    BIOMEDICAL CHROMATOGRAPHY, 2020, 34 (10)
  • [10] Simultaneous Quantitation of S(+)- and R(-)-Baclofen and Its Metabolite in Human Plasma and Cerebrospinal Fluid using LC-APCI-MS/MS: An Application for Clinical Studies
    He, Qingfeng
    Chhonker, Yashpal S.
    McLaughlin, Matthew J.
    Murry, Daryl J.
    MOLECULES, 2020, 25 (02):