Cooling Thermal Comfort and Efficiency Parameters of Ceiling Panels, Underfloor Cooling, Fan-Assisted Radiators, and Fan Coil

被引:4
作者
Vosa, Karl-Villem [1 ,2 ]
Ferrantelli, Andrea [1 ,2 ,3 ]
Kurnitski, Jarek [1 ,2 ,3 ]
机构
[1] Tallinn Univ Technol, Finest Ctr, FinEst Ctr Smart Cities, EE-19086 Tallinn, Estonia
[2] Tallinn Univ Technolo, Nearly Zero Energy Bldg Res Grp, EE-19086 Tallinn, Estonia
[3] Aalto Univ, Dept Civil Engn, FI-02150 Espoo, Finland
关键词
cooling; measurements; ceiling panels; underfloor cooling; fan-assisted radiators; fan coil; energy efficiency; BUILDINGS; PERFORMANCE; SYSTEMS; VENTILATION;
D O I
10.3390/en15114156
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Climate change has brought a compelling need for cooling living spaces to the attention of researchers as well as construction professionals. The problem of overheating enclosures is now exacerbated in traditionally affected areas and is also affecting countries that were previously less prone to the issue. In this paper, we address measurements of thermal comfort and cooling emission efficiency parameters for different devices: ceiling panels, underfloor cooling, fan-assisted radiators, and fan coil. These devices were tested in low and high cooling capacities of up to 40 W/m(2) while also featuring heating dummies to imitate internal heat gains. Air temperatures were measured at different heights, allowing to evaluate the thermal stratification with high accuracy. Thermal comfort differences of the tested systems were quantified by measuring both air velocities and operative temperatures at points of occupancy. In summary, the best-performing cooling devices for the studied cooling applications were the ceiling panels and fan radiators, followed by underfloor cooling, with a limitation of stratification. Because of the strong jet, fan coil units did not achieve thermal comfort within the whole occupied zone. The results can be utilized in future studies for cooling emission efficiency and energy consumption analyses of the different cooling devices.
引用
收藏
页数:19
相关论文
共 32 条
  • [1] Abel E., 2014, HOONETE ENERGIATARVE
  • [2] [Anonymous], NOBE TT TECHNOLOGY T
  • [3] [Anonymous], 2017, 153162 CEN EN
  • [4] [Anonymous], 2004, 14240 CEN EN
  • [5] Arghand Taha, 2019, E3S Web of Conferences, V111, DOI 10.1051/e3sconf/201911105008
  • [6] Influence of the Representative Concentration Pathways (RCP) scenarios on the bioclimatic design strategies of the built environment
    Bienvenido-Huertas, David
    Rubio-Bellido, Carlos
    Marin-Garcia, David
    Canivell, Jacinto
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2021, 72
  • [7] Experimental comparison of thermal comfort during cooling with a fan coil system and radiant floor system at varying space heights
    Cen, Chao
    Jia, Yihong
    Liu, Kuixing
    Geng, Ruoxi
    [J]. BUILDING AND ENVIRONMENT, 2018, 141 : 71 - 79
  • [8] CEN - Comite Europeen de Normalisation, 2019, Part 1: indoor environmental input parameters for design and assessment of energy performance of buildings addressing indoor air quality, thermal environment
  • [9] Large uncertainties in trends of energy demand for heating and cooling under climate change
    Deroubaix, Adrien
    Labuhn, Inga
    Camredon, Marie
    Gaubert, Benjamin
    Monerie, Paul-Arthur
    Popp, Max
    Ramarohetra, Johanna
    Ruprich-Robert, Yohan
    Silvers, Levi G.
    Siour, Guillaume
    [J]. NATURE COMMUNICATIONS, 2021, 12 (01)
  • [10] Analysis and experimental verification of an improved cooling radiator
    Erell, E
    Etzion, Y
    [J]. RENEWABLE ENERGY, 1999, 16 (1-4) : 700 - 703