Automated detection and interpretation of spectral information using cross-correlation, millilitre volumes, pneumatic nebulization sample introduction and inductively coupled plasma-atomic emission spectrometry with photodiode array detection

被引:4
作者
Karanassios, V [1 ]
Drouin, PJ
Spiers, GA
机构
[1] Univ Waterloo, Guelph Waterloo Ctr Grad Work Chem, Dept Chem, Waterloo, ON N2L 3G1, Canada
[2] Res & Prod Council, Fredericton, NB E3B 6Z9, Canada
关键词
ICP-AES; cross-correlation; automated spectral interpretation; user-interface; diode array;
D O I
10.1016/S0584-8547(98)00131-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A method for automated detection and interpretation of spectral information from -230 nm spectral windows, millilitre volume samples for 15 elements is presented. The basic approach involves cross-correlation of a spectral pattern obtained by running laboratory prepared multi-element 'unknowns' with a reference spectral pattern obtained by running a single element standard. From the resultant cross-correlogram, it can be decided whether or not the sought-for reference spectral pattern land the corresponding element) are present in the unknown. Spectral patterns were acquired using an inductively coupled plasma-atomic emission spectrometry (ICP-AES)system equipped with a linear, 1024-element, photo-diode array (Leco, Plasmarray). Reference spectral patterns for Al, Au, Be, Cd, Cu, Ga, Mg, Mn, Ni, Pd, Si, Sc, Y, Sr and Zn were converted to noise-free and interference-free binary software masks and, subsequently, to analogue software masks. Cross-correlation of the analogue masks with spectral patterns acquired by running multi-element unknowns is discussed, an algorithm that does not rely on fast Fourier transforms (FFT) to calculate cross-correlations is presented and a context-sensitive, colour-coded and interrogatable periodic table graphical user-interface that presents the likely composition of an unknown on the computer screen is described in detail. (C) 1998 Elsevier Science B.V. All rights reserved
引用
收藏
页码:1149 / 1166
页数:18
相关论文
共 19 条
[1]  
Bendat JS, 1993, ENG APPL CORRELATION, DOI DOI 10.2514/3.49131
[2]  
BRINGHAM EO, 1988, FAST FOURIER TRANSFO
[3]   CHARACTERIZATION OF A SPECTRALLY SEGMENTED PHOTODIODE-ARRAY SPECTROMETER FOR INDUCTIVELY COUPLED PLASMA ATOMIC EMISSION-SPECTROMETRY [J].
BRUSHWYLER, KR ;
FURUTA, N ;
HIEFTJE, GM .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1991, 46 (01) :85-98
[4]  
BRUSHWYLER KR, 1990, TALANTA, V37, P23
[5]   AN ALGORITHM FOR MACHINE CALCULATION OF COMPLEX FOURIER SERIES [J].
COOLEY, JW ;
TUKEY, JW .
MATHEMATICS OF COMPUTATION, 1965, 19 (90) :297-&
[6]  
HORLICK G, 1978, CONT TOPICS ANAL CLI, V3, P153
[7]  
*IEEE, 1996, IEEE EXP, V11
[8]   SPECTRAL CHARACTERISTICS OF A NEW SPECTROMETER DESIGN FOR ATOMIC EMISSION-SPECTROSCOPY [J].
KARANASSIOS, V ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1986, 40 (06) :813-821
[9]   CORRELATION-BASED DETECTION OF SPECTRAL INFORMATION USING MICROLITER VOLUMES, IN-TORCH VAPORIZATION (ITV) SAMPLE INTRODUCTION AND INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY WITH PHOTODIODE-ARRAY DETECTION [J].
KARANASSIOS, V ;
BATEMAN, KP .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1994, 49 (10) :989-1005
[10]  
KARANASSIOS V, 1998, WINT C PLASM SPECTR