Development of loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay for Mycoplasma pneumoniae detection

被引:37
|
作者
Wang, Yacui [1 ]
Wang, Yi [1 ]
Jiao, Weiwei [1 ]
Li, Jieqiong [1 ]
Quan, Shuting [1 ]
Sun, Lin [1 ]
Wang, Yonghong [1 ]
Qi, Xue [1 ]
Wang, Xingyun [1 ]
Shen, Adong [1 ]
机构
[1] Capital Med Univ, Natl Clin Res Ctr Resp Dis,Natl Key Discipline Pe, Beijing Key Lab Pediat Resp Infect Dis,Minist Edu, Beijing Pediat Res Inst,Beijing Childrens Hosp,Ke, Beijing 100045, Peoples R China
关键词
Mycoplasma pneumoniae; Loop-mediated isothermal amplification; Nanoparticle-based biosensor; Lateral flow biosensor; LAMP-LFB; DIAGNOSIS;
D O I
10.1186/s13568-019-0921-3
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Mycoplasma pneumoniae (MP) is one of the most common pathogens causing respiratory tract infection, especially for community-acquired pneumonia (CAP) in school-age children. There was considerable amount of studies on loop-mediated isothermal amplification (LAMP) assay for MP detection. However, the result interpretation of these developed LAMP assays was sophisticated and subjective. Therefore, we developed and evaluated a LAMP coupled with nanoparticle-based lateral flow biosensor (LFB) assay (LAMP-LFB) for simple, reliable, and objective identification of MP (MP-LAMP-LFB). Six primers specific to P1 gene of MP were designed, and the preferred temperature for this assay was confirmed to be 65 degrees C. The amplification products could be visually interpreted by LFB within 2 min. The MP-LAMP-LFB assay specifically identified DNA templates of MP, and no cross-reactivity with other pathogens was obtained. The limit of the detection for this assay was 600 fg of DNA templates in pure cultures, which was in complete accordance with colorimetric indicator detection and agarose gel electrophoresis analysis. This assay was applied to 209 oropharyngeal swab specimens collected from children with acute respiratory tract infection for clinical evaluation, and compared to real-time PCR detection. Using the LAMP-LFB and real-time PCR assay, the positive rates of MP were 47.8% and 31.6%, respectively. Results suggested that the LAMP-LFB assay displayed high sensitivity compared to real-time PCR method. In summary, LAMP-LFB assay established here was a simple, objective, and sensitive assay for MP detection, which can be widely applied in clinical settings, especially in rural areas.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Development of loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay for Mycoplasma pneumoniae detection
    Yacui Wang
    Yi Wang
    Weiwei Jiao
    Jieqiong Li
    Shuting Quan
    Lin Sun
    Yonghong Wang
    Xue Qi
    Xingyun Wang
    Adong Shen
    AMB Express, 9
  • [2] Detection of Haemophilus influenzae by loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay
    Qilong Cao
    Shaoshuai Liang
    Feng Lin
    Jun Cao
    Lin Wang
    Hui Li
    Mengyang Liu
    Yajuan Wang
    Lijun Zhao
    Xiaolong Cao
    Yan Guo
    BMC Microbiology, 22
  • [3] Detection of Haemophilus influenzae by loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor assay
    Cao, Qilong
    Liang, Shaoshuai
    Lin, Feng
    Cao, Jun
    Wang, Lin
    Li, Hui
    Liu, Mengyang
    Wang, Yajuan
    Zhao, Lijun
    Cao, Xiaolong
    Guo, Yan
    BMC MICROBIOLOGY, 2022, 22 (01)
  • [4] Loop-mediated isothermal amplification coupled with nanoparticle-based lateral flow biosensor for monkeypox virus detection
    Xiao, Fei
    Fu, Jin
    Huang, Xiaolan
    Jia, Nan
    Sun, Chunrong
    Xu, Zheng
    Huang, Hui
    Zhou, Juan
    Wang, Yi
    TALANTA, 2024, 269
  • [5] Loop-Mediated Isothermal Amplification Coupled With Nanoparticle-Based Biosensor: A Rapid and Sensitive Method to Detect Mycoplasma pneumoniae
    Xiao, Fei
    Zhou, Juan
    Sun, Chunrong
    Huang, Xiaolan
    Zheng, Baoying
    Fu, Jin
    Jia, Nan
    Xu, Zheng
    Cui, Xiaodai
    Wang, Yi
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2022, 12
  • [6] A Loop-mediated Isothermal Amplification With a Nanoparticle-Based Lateral Flow Biosensor Assay to Detect Pseudomonas aeruginosa in Endophthalmitis
    Dong, Kui
    Kang, ZhiMing
    Ji, Xuan
    Zhang, Xinxin
    Cheng, PeiNi
    Sun, Bin
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (14):
  • [7] Loop-Mediated Isothermal Amplification Coupled With Nanoparticle-Based Lateral Biosensor for Rapid, Sensitive, and Specific Detection of Bordetella pertussis
    Sun, Chunrong
    Xiao, Fei
    Fu, Jin
    Huang, Xiaolan
    Jia, Nan
    Xu, Zheng
    Wang, Yi
    Cui, Xiaodai
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2022, 9
  • [8] Rapid detection of Mycoplasma pneumoniae by loop-mediated isothermal amplification assay
    Yuan, Xin
    Bai, Changqing
    Cui, Qian
    Zhang, Han
    Yuan, Jing
    Niu, Kaiwen
    Feng, Yuzhong
    Jin, Xin
    Li, Puyuan
    Liu, Huiying
    MEDICINE, 2018, 97 (25)
  • [9] Establishment and Application of a Multiple Cross Displacement Amplification Coupled With Nanoparticle-Based Lateral Flow Biosensor Assay for Detection of Mycoplasma pneumoniae
    Wang, Yacui
    Wang, Yi
    Quan, Shuting
    Jiao, Weiwei
    Li, Jieqiong
    Sun, Lin
    Wang, Yonghong
    Qi, Xue
    Wang, Xingyun
    Shen, Adong
    FRONTIERS IN CELLULAR AND INFECTION MICROBIOLOGY, 2019, 9
  • [10] Simple and rapid detection Aspergillus fumigatus by loop-mediated isothermal amplification coupled with lateral flow biosensor assay
    Jiang, L.
    Gu, R.
    Li, X.
    Mu, D.
    JOURNAL OF APPLIED MICROBIOLOGY, 2021, 131 (05) : 2351 - 2360