Training Persons with Spinal Cord Injury to Ambulate Using a Powered Exoskeleton

被引:47
|
作者
Asselin, Pierre K. [1 ]
Avedissian, Manuel [1 ]
Knezevic, Steven [1 ]
Kornfeld, Stephen [2 ]
Spungen, Ann M. [1 ]
机构
[1] James J Peters VA Med Ctr, Dept Vet Affairs VA, Rehabil Res & Dev Natl Ctr Excellence Med Consequ, Bronx, NY 10468 USA
[2] James J Peters VA Med Ctr, Dept Vet Affairs VA, Spinal Cord Injury Serv, Bronx, NY 10468 USA
来源
JOVE-JOURNAL OF VISUALIZED EXPERIMENTS | 2016年 / 112期
关键词
Bioengineering; Issue; 112; 6MWT; ambulatory device; overground walking; paraplegia; powered exoskeleton; reciprocating gait orthosis; RGO; spinal cord injury; RECIPROCATING GAIT ORTHOSIS; PARAPLEGIC LOCOMOTION; ENERGY-COST; WALKING; REHABILITATION; CLASSIFICATION; PERFORMANCE; EXERCISE; MOBILITY; FRACTURE;
D O I
10.3791/54071
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Powered exoskeletons have become available for overground ambulation in persons with paralyses due to spinal cord injury (SCI) who have intact upper extremity function and are able to maintain upright balance using forearm crutches. To ambulate in an exoskeleton, the user must acquire the ability to maintain balance while standing, sitting and appropriate weight shifting with each step. This can be a challenging task for those with deficits in sensation and proprioception in their lower extremities. This manuscript describes screening criteria and a training program developed at the James J. Peters VA Medical Center, Bronx, NY to teach users the skills needed to utilize these devices in institutional, home or community environments. Before training can begin, potential users are screened for appropriate range of motion of the hip, knee and ankle joints. Persons with SCI are at an increased risk of sustaining lower extremity fractures, even with minimal strain or trauma, therefore a bone mineral density assessment is performed to reduce the risk of fracture. Also, as part of screening, a physical examination is performed in order to identify additional health-related contraindications. Once the person has successfully passed all screening requirements, they are cleared to begin the training program. The device is properly adjusted to fit the user. A series of static and dynamic balance tasks are taught and performed by the user before learning to walk. The person is taught to ambulate in various environments ranging from indoor level surfaces to outdoors over uneven or changing surfaces. Once skilled enough to be a candidate for home use with the exoskeleton, the user is then required to designate a companion-walker who will train alongside them. Together, the pair must demonstrate the ability to perform various advanced tasks in order to be permitted to use the exoskeleton in their home/community environment.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Perspectives of people with spinal cord injury learning to walk using a powered exoskeleton
    Manns, Patricia J.
    Hurd, Caitlin
    Yang, Jaynie F.
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2019, 16 (1)
  • [2] Perspectives of people with spinal cord injury learning to walk using a powered exoskeleton
    Patricia J. Manns
    Caitlin Hurd
    Jaynie F. Yang
    Journal of NeuroEngineering and Rehabilitation, 16
  • [3] The effects of gait training using powered lower limb exoskeleton robot on individuals with complete spinal cord injury
    Cheng-Hua Wu
    Hui-Fen Mao
    Jwu-Sheng Hu
    Ting-Yun Wang
    Yi-Jeng Tsai
    Wei-Li Hsu
    Journal of NeuroEngineering and Rehabilitation, 15
  • [4] A Systematic Review of the Determinants of Implementation of a Locomotor Training Program Using a Powered Exoskeleton for Individuals with a Spinal Cord Injury
    Charette, Caroline
    Dery, Julien
    Blanchette, Andreanne K.
    Faure, Celine
    Routhier, Francois
    Bouyer, Laurent J.
    Lamontagne, Marie-Eve
    CLINICAL REHABILITATION, 2023, 37 (08) : 1119 - 1138
  • [5] The effects of gait training using powered lower limb exoskeleton robot on individuals with complete spinal cord injury
    Wu, Cheng-Hua
    Mao, Hui-Fen
    Hu, Jwu-Sheng
    Wang, Ting-Yun
    Tsai, Yi-Jeng
    Hsu, Wei-Li
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2018, 15
  • [6] The next generation of powered exoskeleton use in spinal cord injury
    Ghobrial, George M.
    Wang, Michael Y.
    NEUROSURGICAL FOCUS, 2017, 42 (05)
  • [7] Walking after incomplete spinal cord injury: changes in muscle activations due to training with a robotic powered exoskeleton
    Bellitto, A.
    Mandraccia, S.
    Leoncini, C.
    Rossi, L.
    Gamba, S.
    Massone, A.
    Casadio, M.
    De Luca, A.
    2020 8TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE FOR BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2020, : 382 - 389
  • [8] Mechanisms for improving walking speed after longitudinal powered robotic exoskeleton training for individuals with spinal cord injury
    Ramanujam, Arvind
    Momeni, Kamyar
    Husain, Syed R.
    Augustine, Jonathan
    Garbarini, Erica
    Barrance, Peter
    Spungen, Ann
    Asselin, Pierre
    Knezevic, Steven
    Forrest, Gail F.
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 2805 - 2808
  • [9] PRELIMINARY DESIGN OF A MUSCLE-POWERED EXOSKELETON FOR USERS WITH SPINAL CORD INJURY
    Brown, Emily
    Ullah, Yusra Farhat
    Gustafson, Kimberly
    Durfee, William
    PROCEEDINGS OF THE 2022 DESIGN OF MEDICAL DEVICES CONFERENCE (DMD2022), 2022,
  • [10] Assistive powered exoskeleton for complete spinal cord injury: correlations between walking ability and exoskeleton control
    Guanziroli, Eleonora
    Cazzaniga, Maurizio
    Colombo, Laura
    Basilico, Sabrina
    Legnani, Giovanni
    Molteni, Franco
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2019, 55 (02) : 209 - 216