Desiccant HVAC system driven by a micro-CHP: Experimental analysis

被引:52
作者
Angrisani, Giovanni [1 ]
Minichiello, Francesco [2 ]
Roselli, Carlo [1 ]
Sasso, Maurizio [1 ]
机构
[1] Univ Sannio, Dipartimento Ingn, I-82100 Benevento, Italy
[2] Univ Naples Federico II, DETEC, I-80125 Naples, Italy
关键词
Decentralized polygeneration; Micro-CHP; Desiccant wheel; Hybrid HVAC system; Experimental analysis; PERFORMANCE;
D O I
10.1016/j.enbuild.2010.06.011
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the Mediterranean area, there is increase in demand for summer cooling satisfied by electrically driven units in domestic and small commercial sectors: this involves electric peak loads and black-outs. Consequently, there is an increasing interest in small scale polygeneration systems fuelled by natural gas. In this paper, attention is paid to a test facility, located in Southern Italy, to carry out experimental analysis on a small scale polygeneration system based on a natural gas-fired Micro-CHP and a desiccant HVAC system. The MCHP provides thermal power, recovered from engine cooling and exhaust gas, for the regeneration of the desiccant wheel and electric power for the chiller, the auxiliaries and the external units (computers, lights, etc.). The HVAC system can also operate in traditional way, by interacting with electric grid and gas-fired boiler. An overview of the main experimental results is shown, considering both the desiccant wheel and the global polygeneration system. The experimental results confirm that the performances of the desiccant wheel are strongly influenced by outdoor thermal-hygrometric air properties and regeneration temperature. The polygeneration system guarantees primary energy savings up to 21.2% and greenhouse-gas emissions reductions up to 38.6% with respect to conventional HVAC systems based on separate energy "production". (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2028 / 2035
页数:8
相关论文
共 19 条
[1]  
ANGRISANI G, 2009, P ECOS 2009 FOZ IG P
[2]   Performance analysis of an innovative small-scale trigeneration plant with liquid desiccant cooling system [J].
Badami, M. ;
Portoraro, A. .
ENERGY AND BUILDINGS, 2009, 41 (11) :1195-1204
[3]  
BOURDOUKAN P, 2008, P ECOS 2008 CRAC GLI
[4]   Hybrid HVAC systems with chemical dehumidification for supermarket applications [J].
Capozzoli, A ;
Mazzei, P ;
Minichiello, F ;
Palma, D .
APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) :795-805
[5]   Experiences with a gas driven, desiccant assisted air conditioning system with geothermal energy for an office building [J].
Casas, W ;
Schmitz, G .
ENERGY AND BUILDINGS, 2005, 37 (05) :493-501
[6]  
Dorer V., 2007, METHODOLOGIES PERFOR
[7]   Micro tri-generation system for indoor air conditioning in the Mediterranean climate [J].
Henning, Hans-Martin ;
Pagano, Tullio ;
Mola, Stefano ;
Wiemken, Edo .
APPLIED THERMAL ENGINEERING, 2007, 27 (13) :2188-2194
[8]  
JALALZADEHAZARA.A, 2005, INT J DISTRIBUTED EN, V1, P163
[9]   Performance of a solar-regenerated liquid desiccant ventilation pre-conditioning system [J].
Katejanekarn, Thosapon ;
Kumar, S. .
ENERGY AND BUILDINGS, 2008, 40 (07) :1252-1267
[10]   New ideas for energy utilisation in combined heat and power with cooling .2. Applications [J].
Lazzarin, RM ;
Gasparella, A .
APPLIED THERMAL ENGINEERING, 1997, 17 (05) :479-500