A drift correction procedure

被引:63
作者
Salit, ML [1 ]
Turk, GC [1 ]
机构
[1] NIST, Chem Sci & Technol Lab, Div Analyt Chem, Gaithersburg, MD 20899 USA
关键词
D O I
10.1021/ac980095b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A procedure is introduced that can mitigate the deleterious effect of low frequency noise-often termed drift-on the precision of an analytical experiment. This procedure offers several performance benefits over traditional designs based on the periodic measurement of standards to diagnose and correct for variation in instrument response, Using repeated measurements of every sample as a drift diagnostic, as opposed to requiring the periodic measurement of any given sample or standard, the analyst can better budget the measurement time to be devoted to each sample, distributing it to optimize the uncertainty of the analytical result. The drift is diagnosed from the repeated measurements, a model of the instrument response drift is constructed, and the data are corrected to a "drift-free" condition. This drift-free condition allows data to be accumulated over long periods of time with little or no loss in precision due to drift. More than 10-fold precision enhancements of analytical atomic emission results have been observed, with no statistically significant effects on the means. The procedure is described, performance data are presented, and matters regarding the procedure are discussed.
引用
收藏
页码:3184 / 3190
页数:7
相关论文
共 9 条
[1]   PREPARATION AND CERTIFICATION OF A RHODIUM STANDARD REFERENCE MATERIAL SOLUTION [J].
BECK, CM ;
SALIT, ML ;
WATTERS, RL ;
BUTLER, TA ;
WOOD, LJ .
ANALYTICAL CHEMISTRY, 1993, 65 (20) :2899-2902
[2]  
BEVINGTON PR, 1992, DATA REDUCTION ERROR, P11
[3]   ROBUST LOCALLY WEIGHTED REGRESSION AND SMOOTHING SCATTERPLOTS [J].
CLEVELAND, WS .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1979, 74 (368) :829-836
[4]  
Hartley R. W., 1979, Laboratory Practice, V28, P839
[5]   IMPROVED PERFORMANCE USING INTERNAL STANDARDIZATION IN INDUCTIVELY-COUPLED PLASMA EMISSION-SPECTROSCOPY [J].
MYERS, SA ;
TRACY, DH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1983, 38 (09) :1227-1253
[6]  
Press W. H., 1992, NUMERICAL RECIPES C
[7]   Correction for drift in multivariate systems using the Kalman filter [J].
Rutan, SC ;
Bouveresse, E ;
Andrew, KN ;
Worsfold, PJ ;
Massart, DL .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 35 (02) :199-211
[8]   EVALUATION OF MEASUREMENTS SUBJECT TO LINEAR DRIFT [J].
SVEHLA, G ;
DICKSON, EL .
ANALYTICA CHIMICA ACTA, 1982, 136 (APR) :369-372
[9]   QUALITY SELF-MONITORING OF INTELLIGENT ANALYZERS AND SENSORS BASED ON AN EXTENDED KALMAN FILTER - AN APPLICATION TO GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROSCOPY [J].
WIENKE, D ;
VIJN, T ;
BUYDENS, L .
ANALYTICAL CHEMISTRY, 1994, 66 (06) :841-849