Determination of Quercetin by a Siloxane-Polyester/Poly-L-Lysine Nanocomposite Modified Glassy Carbon Electrode

被引:9
作者
de Castro Viana Pereira, Elaine Renata [1 ]
Bessegato, Guilherme Garcia [1 ]
Yamanaka, Hideko [1 ]
Boldrin Zanoni, Maria Valnice [1 ]
机构
[1] Univ Estadual Paulista, UNESP, Inst Chem, Dept Analyt Chem, BR-14800060 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Catechol; poly-L-lysine; polysiloxane-poly(propylene) oxide polymer; quercetin; voltammetric sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; ANTIOXIDANT CAPACITY; PHENOLIC-COMPOUNDS; ELECTROCHEMICAL OXIDATION; CYCLIC VOLTAMMETRY; SPECTROPHOTOMETRIC METHODS; BIOLOGICAL-FLUIDS; TEA; FLAVONOIDS; EXTRACTION;
D O I
10.1080/00032719.2015.1104323
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Poly-L-lysine incorporated in the nanocavities of polysiloxane-poly(propylene) oxide is reported as an electrochemical sensor for quercetin. A glassy carbon electrode coated by poly-L-lysine/polysiloxane-poly(propylene) oxide accumulated quercetin through hydrogen bonding in pH 2 ethanol/Britton-Robinson buffer. The catecol oxidation was monitored at 0.45V as a reversible two electron peak. The voltammetric response using the film electrode was 80% higher compared to a bare electrode. Square wave voltammetry was employed using an accumulation time of 8min and a linear relationship was obtained for concentrations of quercetin from 1.0x10(-8)mol L-1 to 1.0x10(-6)mol L-1. The limit of detection was 2.76 +/- 0.5x10(-9)mol L-1. The method was employed to determine quercetin in green tea, but did not show selectivity to catechin, which was oxidized at a similar potential. The measurements were validated by high-performance liquid chromatography.
引用
收藏
页码:1398 / 1411
页数:14
相关论文
共 50 条
[31]   Square wave voltammetric determination of quercetin in wine and fruit juice samples at poly (safranine O) modified glassy carbon electrode [J].
Tesfaye, Gizaw ;
Hailu, Tesfu ;
Ele, Estifanos ;
Negash, Negussie ;
Tessema, Merid .
SENSING AND BIO-SENSING RESEARCH, 2021, 34
[32]   Voltammetric determination of bisoprolol on a glassy carbon electrode modified by poly(arylene phthalide) [J].
Zil'berg, R. A. ;
Yarkaeva, Yu. A. ;
Sidel'nikov, A. V. ;
Maistrenko, V. N. ;
Kraikin, V. A. ;
Gileva, N. G. .
JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (09) :926-931
[33]   Determination of Rutin on the Poly(p-aminobenzene sulfonic acid) Modified Glassy Carbon Electrode [J].
Chen, Xiaoyin ;
Wang, Zonghua ;
Zhang, Feifei ;
Zhu, Lingyan ;
Li, Yanhui ;
Xia, Yanzhi .
CHEMICAL & PHARMACEUTICAL BULLETIN, 2010, 58 (04) :475-478
[34]   Amperometric Determination of Nitrite at Poly(Methylene Blue)-Modified Glassy Carbon Electrode [J].
Xu, Guang-Ri ;
Xu, Guifang ;
Xu, Ming-Lu ;
Zhang, Zhengqing ;
Tian, Yuan ;
Cho, Han Nim ;
Lee, Won-Yong .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2012, 33 (02) :415-419
[35]   Voltammetric determination of bisoprolol on a glassy carbon electrode modified by poly(arylene phthalide) [J].
R. A. Zil’berg ;
Yu. A. Yarkaeva ;
A. V. Sidel’nikov ;
V. N. Maistrenko ;
V. A. Kraikin ;
N. G. Gileva .
Journal of Analytical Chemistry, 2016, 71 :926-931
[36]   Simultaneous determination of hydroquinone and catechol based on glassy carbon electrode modified with gold-graphene nanocomposite [J].
Ma, Xuemei ;
Liu, Zhaona ;
Qiu, Cuicui ;
Chen, Ting ;
Ma, Houyi .
MICROCHIMICA ACTA, 2013, 180 (5-6) :461-468
[37]   Electrochemical study of microperoxidase-11 immobilized on the surface of a poly-L-lysine modified gold electrode [J].
Wagn, FB ;
Zheng, JW ;
Li, XW ;
Yuan, J ;
Ying, G ;
Wei, X ;
Lu, TH .
CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (12) :2268-2270
[38]   Dithiooxamide Modified Glassy Carbon Electrode for the Studies of Non-Aqueous Media: Electrochemical Behaviors of Quercetin on the Electrode Surface [J].
Mulazimoglu, Aysen Demir ;
Yilmaz, Ecir ;
Mulazimoglu, Ibrahim Ender .
SENSORS, 2012, 12 (04) :3916-3928
[39]   Electrochemical and electrocatalytic properties of microperoxidase-11 adsorbed on the poly-L-lysine modified Ag electrode [J].
Wang, FB ;
Jiang, HJ ;
Xing, W ;
Lu, TH ;
Chen, HL .
ACTA PHYSICO-CHIMICA SINICA, 2002, 18 (05) :404-408
[40]   Fabrication of g-C3N4/NiO heterostructured nanocomposite modified glassy carbon electrode for quercetin biosensor [J].
Selvarajan, S. ;
Suganthi, A. ;
Rajarajan, M. .
ULTRASONICS SONOCHEMISTRY, 2018, 41 :651-660