Clinical outcome of anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft and bioabsorbable interference screw fixation

被引:35
作者
Charlton, WPH [1 ]
Randolph, DA [1 ]
Lemos, S [1 ]
Shields, CL [1 ]
机构
[1] Kerlan Jobe Orthopaed Clin, Los Angeles, CA 90045 USA
关键词
D O I
10.1177/03635465030310040701
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: To date, there has been no publication of clinical follow-up data on patients who have undergone quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable screw fixation. Purpose: To report the results of quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bicabsorbable interference screw fixation. Study Design: Retrospective review. Methods: Sixty-five patients (66 knees) were retrospectively identified by chart review as having undergone quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation with a minimum 2-year follow-up. Results: Data were collected on 48 knees in 47 patients (73%) at an average 30.2 months (range, 24 to 43) after surgery. Thirty-six patients (37 knees) returned for clinical evaluation (56% return) and subjective follow-up only was obtained in 11 patients (17%). The mean Lysolm knee score was 91 (range, 45 to 98), with a mean of 97 for the uninvolved knee. The mean Tegner activity score was 5.7 (range, 3 to 7). The KT-1000 arthrometer mean side-to-side difference for manual maximum displacement was 2.03 mm (range, -1 to 8). The mean International Knee Documentation Committee knee score was 83 (range, 47 to 100). Patients who underwent associated partial meniscectomy or meniscal repair had significantly lower International Knee Documentation Committee scores than patients without associated procedures (P < 0.01). Conclusions: Quadrupled hamstring tendon autograft anterior cruciate ligament reconstruction with bioabsorbable interference screw fixation is comparable with other methods of anterior cruciate ligament reconstruction in terms of patient satisfaction, knee stability, and function. (C) 2003 American Orthopaeclic Society for Sports Medicine.
引用
收藏
页码:518 / 521
页数:4
相关论文
共 18 条
[1]   Tripled semitendinosus-cancellous bone anterior cruciate ligament reconstruction with bioscrew fixation [J].
Barber, FA .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 1999, 15 (04) :360-367
[2]   Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque [J].
Brand, JC ;
Pienkowski, D ;
Steenlage, E ;
Hamilton, D ;
Johnson, DL ;
Caborn, DNM .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (05) :705-710
[3]   Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: A comparison between a metal and a bioabsorbable interference screw [J].
Caborn, DNM ;
Coen, M ;
Neef, R ;
Hamilton, D ;
Nyland, J ;
Johnson, DL .
ARTHROSCOPY, 1998, 14 (03) :241-245
[4]   Tunnel widening in anterior cruciate ligament reconstruction: a prospective evaluation of hamstring and patella tendon grafts [J].
Clatworthy, MG ;
Annear, P ;
Bulow, JU ;
Bartlett, RJ .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (03) :138-145
[5]   Arthroscopic reconstruction of the anterior cruciate ligament - A comparison of patellar tendon autograft and four-strand hamstring tendon autograft [J].
Corry, IS ;
Webb, JM ;
Clingeleffer, AJ ;
Pinczewski, LA .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (04) :444-454
[6]   A comparison of quadruple semitendinosus and patellar tendon grafts in reconstruction of the anterior cruciate ligament [J].
Eriksson, K ;
Anderberg, P ;
Hamberg, P ;
Löfgren, AC ;
Bredenberg, M ;
Westman, I ;
Wredmark, T .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (03) :348-354
[7]  
Hefti F, 1993, Knee Surg Sports Traumatol Arthrosc, V1, P226
[8]   The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability: Evaluation using a robotic testing system [J].
Ishibashi, Y ;
Rudy, TW ;
Livesay, GA ;
Stone, JD ;
Fu, FH ;
Woo, SLY .
ARTHROSCOPY, 1997, 13 (02) :177-182
[9]   Bone tunnel enlargement after anterior cruciate ligament reconstruction with the hamstring autograft and endobutton fixation technique - A clinical, radiographic and magnetic resonance imaging study with 2 years follow-up [J].
Jansson, KA ;
Harilainen, A ;
Sandelin, J ;
Karjalainen, PT ;
Aronen, HJ ;
Tallroth, K .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (05) :290-295
[10]   EVALUATION OF KNEE LIGAMENT SURGERY RESULTS WITH SPECIAL EMPHASIS ON USE OF A SCORING SCALE [J].
LYSHOLM, J ;
GILLQUIST, J .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1982, 10 (03) :150-154