Seeking Inspiration: Examining the Validity and Reliability of a New Smartphone Respiratory Therapy Exergame App

被引:6
作者
Baxter, Clarence [1 ,2 ]
Carroll, Julie-Anne [1 ,2 ]
Keogh, Brendan [3 ]
Vandelanotte, Corneel [4 ]
机构
[1] Queensland Univ Technol, Fac Hlth, Sch Publ Hlth & Social Work, Kelvin Grove 4059, Australia
[2] Queensland Univ Technol, Inst Hlth & Biomed Innovat, Sch Publ Hlth & Social Work, Kelvin Grove 4059, Australia
[3] Queensland Univ Technol, Creat Ind Educ & Social Justice Fac, Digital Media Res Ctr, Kelvin Grove 4059, Australia
[4] Cent Queensland Univ, Appleton Inst, Phys Act Res Grp, Rockhampton, Qld 4702, Australia
关键词
telemedicine; mHealth; respiratory; smartphone; cellphone; digital simulation; microphone; gamification; serious game; exergame; INCENTIVE SPIROMETRY; FLOW-RATE; PULMONARY-FUNCTION; SOUND; REHABILITATION; METHODOLOGY; PREVALENCE; ACCURACY; PATIENT; RATES;
D O I
10.3390/s21196472
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Clinically valid and reliable simulated inspiratory sounds were required for the development and evaluation of a new therapeutic respiratory exergame application (i.e., QUT Inspire). This smartphone application virtualises incentive spirometry, a longstanding respiratory therapy technique. Objectives: Inspiratory flows were simulated using a 3 litre calibration syringe and validated using clinical reference devices. Syringe flow nozzles of decreasing diameter were applied to model the influence of mouth shape on audible sound levels generated. Methods: A library of calibrated audio inspiratory sounds was created to determine the reliability and range of inspiratory sound detection at increasing distances separating the sound source and smartphones running the app. Results: Simulated inspiratory sounds were reliably detected by the new application at higher air inflows (high, medium), using smaller mouth diameters (< 25 mm) and where smartphones were held proximal (<= 5 cm) to the mouth (or at distances up to 50 cm for higher airflows). Performance was comparable for popular smartphone types and using different phone orientations (i.e., held horizontally, at 45 degrees or 90 degrees). Conclusions: These observations inform future application refinements, including prompts to reduce mouth diameter, increase inspiratory flow and maintain proximity to the phone to optimise sound detection. This library of calibrated inspiratory sounds offers reproducible non-human reference data suitable for development, evaluation and regression testing of a therapeutic respiratory exergame application for smartphones.
引用
收藏
页数:17
相关论文
共 59 条
[41]   Vortex Whistle and Smart Phone Application for Peak Flow Recordings in Asthmatic Children: A Feasibility Study [J].
Mikalsen, Ingvild Bruun ;
Nassehi, Damoun ;
Oymar, Knut .
TELEMEDICINE AND E-HEALTH, 2019, 25 (11) :1077-1082
[42]   Standardisation of spirometry [J].
Miller, MR ;
Hankinson, J ;
Brusasco, V ;
Burgos, F ;
Casaburi, R ;
Coates, A ;
Crapo, R ;
Enright, P ;
van der Grinten, CPM ;
Gustafsson, P ;
Jensen, R ;
Johnson, DC ;
MacIntyre, N ;
McKay, R ;
Navajas, D ;
Pedersen, OF ;
Pellegrino, R ;
Viegi, G ;
Wanger, J .
EUROPEAN RESPIRATORY JOURNAL, 2005, 26 (02) :319-338
[43]   Testing the accuracy of smartphones and sound level meter applications for measuring environmental noise [J].
Murphy, Enda ;
King, Eoin A. .
APPLIED ACOUSTICS, 2016, 106 :16-22
[44]   Estimation of Respiratory Rates Using the Built-in Microphone of a Smartphone or Headset [J].
Nam, Yunyoung ;
Reyes, Bersain A. ;
Chon, Ki H. .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (06) :1493-1501
[45]   Respiratory sounds in healthy people: A systematic review [J].
Oliveira, Ana ;
Marques, Alda .
RESPIRATORY MEDICINE, 2014, 108 (04) :550-570
[46]   An overview on the emerging area of identification, characterization, and assessment of health apps [J].
Paglialonga, Alessia ;
Lugo, Alessandra ;
Santoro, Eugenio .
JOURNAL OF BIOMEDICAL INFORMATICS, 2018, 83 :97-102
[47]   Exergaming and rehabilitation: A methodology for the design of effective and safe therapeutic exergames [J].
Pirovano, Michele ;
Surer, Elif ;
Mainetti, Renato ;
Lanzi, Pier Luca ;
Borghese, N. Alberto .
ENTERTAINMENT COMPUTING, 2016, 14 :55-65
[48]   Phonospirometry for noninvasive measurement of ventilation: methodology and preliminary results [J].
Que, CL ;
Kolmaga, C ;
Durand, LG ;
Kelly, SM ;
Macklem, PT .
JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (04) :1515-1526
[49]   Incentive Spirometry: 2011 [J].
Restrepo, Ruben D. ;
Wettstein, Richard ;
Wittnebel, Leo ;
Tracy, Michael .
RESPIRATORY CARE, 2011, 56 (10) :1600-1604
[50]  
Sharma G, 2017, COPD-J COPD FDN, V4, P217, DOI 10.15326/jcopdf.4.3.2017.0183