Novel design of a miniature loop heat pipe evaporator for electronic cooling

被引:37
作者
Singh, Randeep
Akbarzadeh, Aliakbar
Dixon, Chris
Mochizuki, Masataka
机构
[1] RMIT Univ, Mech & Manufacturing Engn, Sch Aerosp, Energy CARE Grp, Bundoora, Vic 3083, Australia
[2] Fujikura Ltd, Koto Ku, Tokyo 135, Japan
来源
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME | 2007年 / 129卷 / 10期
关键词
flat evaporator; novel design; electronic cooling; miniature loop heat pipe; mLHP; thermal control;
D O I
10.1115/1.2754945
中图分类号
O414.1 [热力学];
学科分类号
摘要
Miniature loop heat pipes (mLHPs) are coming up with a promising solution for the thermal management of futuristic electronics systems. In order to implement these devices inside compact electronics, their evaporator has to be developed with small thickness while preserving the unique thermal characteristics and physical concept of the loop scheme. This paper specifically addresses the design and testing of a mLHP with a flat evaporator only 5 mm thick for the cooling of high performance microprocessors for electronic devices. A novel concept was used to achieve very small thickness for the mLHP evaporator in which the compensation chamber was positioned on the sides of the wick structure and incorporated in the same plane as the evaporator This is unlike the conventional design of the flat evaporator for mLHP in which the compensation chamber, as a rule, adds to the overall thickness of the evaporator The loop was made from copper with water as the heat transfer fluid. For capillary pumping of the working fluid around the loop, a sintered nickel wick with 3-5 mu m pore radius and 75% porosity was used. In the horizontal orientation, the device was able to transfer heat fluxes of 50 W/cm(2) at a distance of up to 150 mm by using a transport line with 2 mm internal diameter In the range of applied power the evaporator was able to achieve steady state without any temperature overshoots or symptoms of capillary structure dryouts. For the evaporator and condenser at the same level and under forced air cooling, the minimum value of 0.62 degrees C/W for mLHP thermal resistance from evaporator to condenser (R,,) was achieved at a maximum heat load of 50 W with the corresponding junction temperature of 98.5 degrees C. The total thermal resistance (R-t) of the mLHP was within 1.5-5.23 degrees C/W. At low heat loads, the mLHP showed some thermal and hydraulic oscillations in the transport lines, which were predominately due to the flow instabilities imposed by parasitic heat leaks to the compensation chamber It is concluded form the outcomes of the present investigation that the proposed design of the mLHP evaporator can be effectively used for the thermal control of the compact electronic devices with high heat flux capabilities.
引用
收藏
页码:1445 / 1452
页数:8
相关论文
共 31 条
[1]  
AGATA H, 2004, P 1 INT S MICR NAN T
[2]  
Alexander E. G., 1972, Ph.D. Thesis
[3]  
CENGEL YA, 2001, FUNDAMENTALS THERMAL, pCH18
[4]  
CHEMYSHEVA MA, 2002, P 12 INT HEAP PIP C, P134
[5]  
CHEN Y, 2005, P 3 INT C MICR MIN T
[6]  
CHEUNG KH, 1998, P 28 INT C ENV SYST
[7]  
Chu C. I., 2004, Heat Transfer-Asian Research, V33, P42, DOI 10.1002/htj.10133
[8]  
Delil A. A. M., 2003, P 33 INT C ENV SYST
[9]  
DELIL AAM, 2002, P 12 INT HEAT PIP C, P126
[10]  
DEVARAKONDA A, 2005, P SPAC TECHN APPL IN