Systematic review of cardiac output measurements by echocardiography vs. thermodilution: the techniques are not interchangeable

被引:80
作者
Wetterslev, Mik [1 ]
Moller-Sorensen, Hasse [2 ]
Johansen, Rasmus Rothmann [1 ]
Perner, Anders [1 ]
机构
[1] Rigshosp, Dept Intens Care, Sect 4131, Copenhagen Univ Hosp, DK-2100 Copenhagen, Denmark
[2] Rigshosp, Dept Cardiothorac Anaesthesiol, Copenhagen Univ Hosp, Copenhagen, Denmark
关键词
Cardiac output; Critical care; Echocardiography; Hemodynamic monitoring; Intensive care unit; Thermodilution technique; PULMONARY-ARTERY CATHETER; MECHANICALLY VENTILATED PATIENTS; RIGHT HEART CATHETERIZATION; WAVE DOPPLER MEASUREMENT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; TRICUSPID REGURGITATION; AMERICAN-SOCIETY; TRENDING ABILITY; CONTROLLED TRIAL;
D O I
10.1007/s00134-016-4258-y
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Echocardiography is frequently used in the hemodynamic evaluation of critically ill patients, but inaccurate measurements may lead to wrong clinical decisions. The aim of our systematic review was to investigate the interchangeability of echocardiography with thermodilution technique in measuring cardiac output and its changes. In August 2015 we systematically searched electronic databases and included studies investigating the echocardiographic measurement of cardiac output compared with thermodilution technique using the Bland-Altman method. Two authors independently reviewed the studies and extracted data on type of measurements, clinical setting and characteristics, and those of the Bland-Altman and trending ability analyses. We identified 13,834 citations and included 24 studies in the final analysis. The median number of participants was 32 (range 8-65). Most of the studies assessed left-sided heart structures and the majority had small bias, wide limits of agreement, and high percentage error between echocardiography and thermodilution. In only two of the 24 studies the precision of each technique (echocardiography and thermodilution) was assessed before comparing them. In the single study evaluating trending ability using valid methodology, agreement was observed between echocardiography and thermodilution in detecting the directional changes in cardiac output, but the magnitude of changes varied considerably. The majority of studies comparing echocardiography with thermodilution were difficult to interpret, but current evidence does not support interchangeability between these techniques in measuring cardiac output. The techniques may be interchangeable in tracking directional changes in cardiac output, but this has to be confirmed in large high-quality studies.
引用
收藏
页码:1223 / 1233
页数:11
相关论文
共 66 条
[1]  
[Anonymous], ANESTHESIOLOGY
[2]   PEEP-induced tricuspid regurgitation [J].
Artucio, H ;
Hurtado, J ;
Zimet, L ;
dePaula, J ;
Beron, M .
INTENSIVE CARE MEDICINE, 1997, 23 (08) :836-840
[3]   Comparison of transesophageal echocardiographic, Fick, and thermodilution cardiac output in critically ill patients [J].
Axler, O ;
Tousignant, C ;
Thompson, CR ;
DallavaSantucci, J ;
Phang, PT ;
Russell, JA ;
Walley, KR .
JOURNAL OF CRITICAL CARE, 1996, 11 (03) :109-116
[4]   Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution [J].
Balik, M ;
Pachl, J ;
Hendl, J .
INTENSIVE CARE MEDICINE, 2002, 28 (08) :1117-1121
[5]   Researcher bias and generalization of results in bias and limits of agreement analyses:: a commentary based on the review of 50 Acta Anaesthesiologica Scandinavica papers using the Altman-Bland approach [J].
Berthelsen, P. G. ;
Nilsson, L. B. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2006, 50 (09) :1111-1113
[6]   Thermodilution cardiac output - Cold vs. room temperature injectate and the importance of measuring the injectate temperature in the right atrium [J].
Berthelsen, PG ;
Eldrup, N ;
Nilsson, LB ;
Rasmussen, JP .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (09) :1103-1110
[7]   Transoesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilution [J].
Bettex, DA ;
Hinselmann, V ;
Hellermann, JP ;
Jenni, R ;
Schmid, ER .
ANAESTHESIA, 2004, 59 (12) :1184-1192
[8]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[9]   Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine [J].
Cecconi, Maurizio ;
De Backer, Daniel ;
Antonelli, Massimo ;
Beale, Richard ;
Bakker, Jan ;
Hofer, Christoph ;
Jaeschke, Roman ;
Mebazaa, Alexandre ;
Pinsky, Michael R. ;
Teboul, Jean Louis ;
Vincent, Jean Louis ;
Rhodes, Andrew .
INTENSIVE CARE MEDICINE, 2014, 40 (12) :1795-1815
[10]   Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies - with specific reference to the measurement of cardiac output [J].
Cecconi, Maurizio ;
Rhodes, Andrew ;
Poloniecki, Jan ;
Della Rocca, Giorgio ;
Grounds, R. Michael .
CRITICAL CARE, 2009, 13 (01)