THE RELIABILITY OF THREE DEVICES USED FOR MEASURING VERTICAL JUMP HEIGHT

被引:141
作者
Nuzzo, James L. [1 ]
Anning, Jonathan H. [1 ]
Scharfenberg, Jessica M. [1 ]
机构
[1] Slippery Rock Univ, Dept Exercise & Rehabilitat Sci, Slippery Rock, PA 16057 USA
关键词
Vertec; Just Jump system; contact mat; Myotest; accelerometer; SPORTS-MEDICINE; STATISTICAL-METHODS; ASSESSING AGREEMENT; FOOTBALL PLAYERS; RATIO SCALE; PERFORMANCE; POWER; STRENGTH; SCIENCE; TESTS;
D O I
10.1519/JSC.0b013e3181fee650
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Nuzzo, JL, Anning, JH, and Scharfenberg, JM. The reliability of three devices used for measuring vertical jump height. J Strength Cond Res 25(9): 2580-2590, 2011-The purpose of this investigation was to assess the intrasession and intersession reliability of the Vertec, Just Jump System, and Myotest for measuring countermovement vertical jump (CMJ) height. Forty male and 39 female university students completed 3 maximal-effort CMJs during 2 testing sessions, which were separated by 24-48 hours. The height of the CMJ was measured from all 3 devices simultaneously. Systematic error, relative reliability, absolute reliability, and heteroscedasticity were assessed for each device. Systematic error across the 3 CMJ trials was observed within both sessions for males and females, and this was most frequently observed when the CMJ height was measured by the Vertec. No systematic error was discovered across the 2 testing sessions when the maximum CMJ heights from the 2 sessions were compared. In males, the Myotest demonstrated the best intrasession reliability (intraclass correlation coefficient [ICC] = 0.95; SEM = 1.5 cm; coefficient of variation [CV] = 3.3%) and intersession reliability (ICC = 0.88; SEM = 2.4 cm; CV = 5.3%; limits of agreement = -0.08 +/- 4.06 cm). Similarly, in females, the Myotest demonstrated the best intrasession reliability (ICC = 0.91; SEM = 1.4 cm; CV = 4.5%) and intersession reliability (ICC = 0.92; SEM = 1.3 cm; CV = 4.1%; limits of agreement = 0.33 +/- 3.53 cm). Additional analysis revealed that heteroscedasticity was present in the CMJ when measured from all 3 devices, indicating that better jumpers demonstrate greater fluctuations in CMJ scores across testing sessions. To attain reliable CMJ height measurements, practitioners are encouraged to familiarize athletes with the CMJ technique and then allow the athletes to complete numerous repetitions until performance plateaus, particularly if the Vertec is being used.
引用
收藏
页码:2580 / 2590
页数:11
相关论文
共 32 条
[1]   Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine [J].
Atkinson, G ;
Nevill, AM .
SPORTS MEDICINE, 1998, 26 (04) :217-238
[2]  
Black W., 1994, J STRENGTH COND RES, V8, P80
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Power versus strength-power jump squat training: Influence on the load-power relationship [J].
Cormie, Prue ;
McCaulley, Grant O. ;
McBride, Jeffrey M. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (06) :996-1003
[5]  
Fatouros IG, 2000, J STRENGTH COND RES, V14, P470
[6]  
Fry A.C., 1991, J APPL SPORT SCI RES, V5, P126
[7]  
Gehri DJ, 1998, J STRENGTH COND RES, V12, P85
[8]  
Harman EA., 1991, J APPL SPORT SCI RES, V5, P116
[9]  
Holcomb WR., 1996, J STRENGTH COND RES, V10, P89
[10]   Measures of reliability in sports medicine and science [J].
Hopkins, WG .
SPORTS MEDICINE, 2000, 30 (01) :1-15