Potentiometric titration of polyhexamethylene biguanide hydrochloride with potassium poly(vinyl sulfate) solution using a cationic surfactant-selective electrode

被引:17
作者
Masadome, Takashi [1 ]
Yamagishi, Yuichi [1 ]
Takano, Masaki [1 ]
Hattori, Toshiaki [2 ]
机构
[1] Shibaura Inst Technol, Fac Engn, Dept Appl Chem, Koto Ku, Tokyo 1358548, Japan
[2] Toyohashi Univ Technol, Dept Mat Sci, Toyohashi, Aichi 4418580, Japan
关键词
D O I
10.2116/analsci.24.415
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric titration method using a cationic surfactant as an indicator cation and a plasticized poly(vinyl chloride) membrane electrode sensitive to the cationic surfactant is proposed for the determination of polyhexamethylene biguanide hydrochloride (PHMB-HCl), which is a cationic polyelectrolyte. A sample solution of PHMB-HCl containing an indicator cation (hexadecyltrimethylammonium ion, HTA) was titrated with a standard solution of an anionic polyelectrolyte, potassium poly(vinyl sulfate) (PVSK). The end-point was detected as a sharp potential change due to an abrupt decrease in the concentration of the indicator cation, HTA, which is caused by its association with PVSK. The effects of the concentrations of HTA ion and coexisting electrolytes in the sample solution on the degree of the potential change at the end-point were examined. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant exists in the concentration range from 2.0 x 10(-5) to 4.0 x 10(-4) M in the case that the concentration of HTA is 1.0 x 10(-5) M, and that from 1.0 x 10(-6) to 1.2 x 10(-5) M in the case that the concentration of HTA is 5.0 x 10(-6) M, respectively. The proposed method was applied to the determination of PHMB-HCl in some contact-lens detergents.
引用
收藏
页码:415 / 418
页数:4
相关论文
共 44 条
[21]   HEPARIN-RESPONSIVE ELECTROCHEMICAL SENSOR - A PRELIMINARY-STUDY [J].
MA, SC ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1992, 64 (06) :694-697
[22]   FLOW-INJECTION ANALYSIS OF NONIONIC SURFACTANTS USING IONIC SURFACTANT-SELECTIVE ELECTRODE DETECTOR [J].
MASADOME, T ;
IMATO, T ;
ISHIBASHI, N .
ANALYTICAL SCIENCES, 1990, 6 (04) :605-606
[23]  
MASADOME T, 1990, BUNSEKI KAGAKU, V39, P519
[24]   Use of marker ion and cationic surfactant plastic membrane electrode for potentiometric titration of cationic polyelectrolytes [J].
Masadome, T ;
Imato, T .
TALANTA, 2003, 60 (04) :663-668
[25]   Determination of anionic polyelectrolytes using a photometric titration with crystal violet as a color indicator [J].
Masadome, T ;
Hoshi, Y .
MICROCHIMICA ACTA, 2003, 142 (1-2) :37-41
[26]   EFFECT OF HYDROPHOBICITY OF MARKER ANIONS ON THE SENSITIVITY OF END-POINT DETECTION FOR POTENTIOMETRIC TITRATIONS OF ANIONIC POLYELECTROLYTES [J].
MASADOME, T ;
IMATO, T .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (06) :596-597
[27]   Determination of cationic polyelectrolytes using a photometric titration with crystal violet as a color indicator [J].
Masadome, T .
TALANTA, 2003, 59 (04) :659-666
[28]   Sensitive end-point detection for potentiometric titration of cationic polyelectrolytes using marker cation and marker cation-selective electrodes [J].
Masadome, T ;
Imato, T .
ANALYTICAL COMMUNICATIONS, 1997, 34 (09) :257-259
[29]   End-point detection of the potentiometric titration of anionic polyelectrolytes using an anionic surfactant-selective plasticized poly (vinyl chloride) membrane electrode and an anionic surfactant as a marker ion [J].
Masadome, T ;
Imato, T ;
Asano, Y .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 363 (03) :241-245
[30]   Photometric titration of anionic polyelectrolytes using the cationic dye as a color indicator [J].
Masadome, T ;
Kawaguchi, M ;
Kurniasari, L .
ANALYTICAL LETTERS, 2003, 36 (03) :619-625