Potentiometric titration of polyhexamethylene biguanide hydrochloride with potassium poly(vinyl sulfate) solution using a cationic surfactant-selective electrode

被引:17
作者
Masadome, Takashi [1 ]
Yamagishi, Yuichi [1 ]
Takano, Masaki [1 ]
Hattori, Toshiaki [2 ]
机构
[1] Shibaura Inst Technol, Fac Engn, Dept Appl Chem, Koto Ku, Tokyo 1358548, Japan
[2] Toyohashi Univ Technol, Dept Mat Sci, Toyohashi, Aichi 4418580, Japan
关键词
D O I
10.2116/analsci.24.415
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A potentiometric titration method using a cationic surfactant as an indicator cation and a plasticized poly(vinyl chloride) membrane electrode sensitive to the cationic surfactant is proposed for the determination of polyhexamethylene biguanide hydrochloride (PHMB-HCl), which is a cationic polyelectrolyte. A sample solution of PHMB-HCl containing an indicator cation (hexadecyltrimethylammonium ion, HTA) was titrated with a standard solution of an anionic polyelectrolyte, potassium poly(vinyl sulfate) (PVSK). The end-point was detected as a sharp potential change due to an abrupt decrease in the concentration of the indicator cation, HTA, which is caused by its association with PVSK. The effects of the concentrations of HTA ion and coexisting electrolytes in the sample solution on the degree of the potential change at the end-point were examined. A linear relationship between the concentration of PHMB-HCl and the end-point volume of the titrant exists in the concentration range from 2.0 x 10(-5) to 4.0 x 10(-4) M in the case that the concentration of HTA is 1.0 x 10(-5) M, and that from 1.0 x 10(-6) to 1.2 x 10(-5) M in the case that the concentration of HTA is 5.0 x 10(-6) M, respectively. The proposed method was applied to the determination of PHMB-HCl in some contact-lens detergents.
引用
收藏
页码:415 / 418
页数:4
相关论文
共 44 条
[1]   Determination of chlorhexidine digluconate and polyhexamethylene biguanide in eye drops by capillary electrophoresis with contactless conductivity detection [J].
Abad-Villar, EM ;
Etter, SF ;
Thiel, MA ;
Hauser, PC .
ANALYTICA CHIMICA ACTA, 2006, 561 (1-2) :133-137
[2]   Bioanalytical applications of polyion-sensitive electrodes [J].
Dai, S ;
Esson, JM ;
Lutze, O ;
Ramamurthy, N ;
Yang, VC ;
Meyerhoff, ME .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :1-14
[3]   Determination of DNA and its binding to protamine using potentiometric polyion sensors [J].
Durust, Nedime ;
Meyerhoff, Mark E. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 602 (01) :138-141
[4]   Polyion-sensitive membrane electrodes for detecting phosphate-rich biological polyanions [J].
Esson, JM ;
Meyerhoff, ME .
ELECTROANALYSIS, 1997, 9 (17) :1325-1330
[5]   Polyelectrolyte-surfactant complexes: an aqueous titration method to model ion-pairing within polymeric membranes of polyion-sensitive electrodes [J].
Esson, JM ;
Ramamurthy, N ;
Meyerhoff, ME .
ANALYTICA CHIMICA ACTA, 2000, 404 (01) :83-94
[6]   POLYMER MEMBRANE-BASED POLYION SENSORS - DEVELOPMENT, RESPONSE MECHANISM, AND BIOANALYTICAL APPLICATIONS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
WANG, EJ ;
YANG, VC ;
MEYERHOFF, ME .
ELECTROANALYSIS, 1995, 7 (09) :823-829
[7]   RESPONSE MECHANISM OF POLYMER MEMBRANE-BASED POTENTIOMETRIC POLYION SENSORS [J].
FU, B ;
BAKKER, E ;
YUN, JH ;
YANG, VC ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (14) :2250-2259
[8]   Voltammetric detection of the polycation protamine by the use of electrodes modified with self-assembled monolayers of thioctic acid [J].
Gadzekpo, VPY ;
Xiao, KP ;
Aoki, H ;
Bühlmann, P ;
Umezawa, Y .
ANALYTICAL CHEMISTRY, 1999, 71 (22) :5109-5115
[9]   Development of an ion-channel sensor for heparin detection [J].
Gadzekpo, VPY ;
Bühlmann, P ;
Xiao, KP ;
Aoki, H ;
Umezawa, Y .
ANALYTICA CHIMICA ACTA, 2000, 411 (1-2) :163-173
[10]   Determination of biguanide groups in polyhexamethylene biguanide hydrochloride by titrimetric methods [J].
Hattori, T ;
Nakata, Y ;
Kato, R .
ANALYTICAL SCIENCES, 2003, 19 (11) :1525-1528