Time-resolved all fiber fluorescence spectroscopy system

被引:0
作者
Chen, A. Y. H. [1 ]
Vanholsbeeck, F. [1 ]
Tai, D. C. S.
Svrcek, M. [2 ,3 ]
Smaill, B. H. [2 ]
机构
[1] Univ Auckland, Dept Phys, Auckland 1, New Zealand
[2] Univ Auckland, Dept Physiol, Auckland 1, New Zealand
[3] Brno Univ Technol, Dept Biomed Engn, Brno, Czech Republic
来源
OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS X | 2010年 / 7559卷
关键词
action potential; optical fiber probe; motion artifact; di-4-ANEPPS; membrane potential; optical mapping;
D O I
10.1117/12.840811
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a simple fiber optic fluorescence spectrometry system with a wide variety of biomedical applications. This low-cost, all-fiber system is portable, robust and has the capacity to acquire fluorescence spectra at rates up to 1 kHz. We demonstrate the capabilities of the system by presenting experimental measurements of action potentials in the di-4-ANEPPS stained rat heart using spectral analysis.
引用
收藏
页数:6
相关论文
共 7 条
[1]   SUPPRESSION OF MOTION ARTIFACTS IN FLUORESCENCE SPECTROSCOPY OF PERFUSED HEARTS [J].
BRANDES, R ;
FIGUEREDO, VM ;
CAMACHO, SA ;
MASSIE, BM ;
WEINER, MW .
AMERICAN JOURNAL OF PHYSIOLOGY, 1992, 263 (03) :H972-H980
[2]   High-speed, random-access fluorescence microscopy: II. Fast quantitative measurements with voltage-sensitive dyes [J].
Bullen, A ;
Saggau, P .
BIOPHYSICAL JOURNAL, 1999, 76 (04) :2272-2287
[3]   Ratiometric intracellular calcium imaging in the isolated beating rat heart using indo-1 fluorescence [J].
Eerbeek, O ;
Mik, EG ;
Zuurbier, CJ ;
van 't Loo, M ;
Donkersloot, C ;
Ince, C .
JOURNAL OF APPLIED PHYSIOLOGY, 2004, 97 (06) :2042-2050
[4]   Intramural multisite recording of transmembrane potential in the heart [J].
Hooks, DA ;
LeGrice, IJ ;
Harvey, JD ;
Smaill, BH .
BIOPHYSICAL JOURNAL, 2001, 81 (05) :2671-2680
[5]   Ratiometry of transmembrane voltage-sensitive fluorescent dye emission in hearts [J].
Knisley, SB ;
Justice, RK ;
Kong, W ;
Johnson, PL .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (03) :H1421-H1433
[6]   DESIGN AND USE OF AN OPTRODE FOR OPTICAL RECORDINGS OF CARDIAC ACTION-POTENTIALS [J].
NEUNLIST, M ;
ZOU, SZ ;
TUNG, L .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1992, 420 (5-6) :611-617
[7]   Illumination and fluorescence collection volumes for fiber optic probes in tissue [J].
Tai, Dean C. S. ;
Hooks, Darren A. ;
Harvey, John D. ;
Smaill, Bruce H. ;
Soeller, Christian .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (03)