Finite element model of the proximal femur under consideration of the hip centralizing forces of the iliotibial tract

被引:21
作者
Birnbaum, K. [1 ]
Pandorf, T. [2 ]
机构
[1] Orthopaed Clin Hennef, D-53773 Hennef, Germany
[2] CeramTec AG, D-73207 Plochingen, Germany
关键词
Biomechanics; Femoral neck angle; Finite element method; Hip joint; Iliotibial tract; MUSCLE FORCES; BONE; ARTHROPLASTY; STRESS; DESIGN; JOINT; RECONSTRUCTION;
D O I
10.1016/j.clinbiomech.2010.09.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: The aim of our investigations was the development of a finite element model of the hip joint under consideration of the hip centralizing forces of the iliotibial tract within different femoral neck angles and its influence to the centralizing of the femoral head to the acetabulum. Methods: For the development of the finite element model of the femur and the iliotibial tract we utilized the program IDEAS 3D as well as the material/lengthening characteristics of the iliotibial tract. In the following step we developed a hip joint model with different centrum-collum-diaphysis-angles of 115 degrees, 128 degrees and 155 degrees for determination of the IT force and the consequential force on the femoral head. Findings: With a coxa vara the force on the femoral head in relation to the physiological centrum-collum-diaphysis-angle and the coxa valga decreased (115 degrees = 1601 N, 128 degrees = 2360 N, and 155 degrees = 2422 N). On the other side the hip centralizing forces of the iliotibial tract within a coxa vara increased in comparison to 128 (physiological) and 155 degrees (valga) (115 degrees = 997 N, 128 degrees = 655,5 N, and 155 degrees = 438 N). Within a coxa valga a higher compressive force on the femoral head and with a coxa vara a decreasing compressive force on the femoral head occurred. Interpretation: The clinical relevance consists in the predictability of an increasing or decreasing band wiring effect of the iliotibial tract in reliance to the centrum-collum-diaphysis-angle of the femoral neck and its importance for the displacement osteotomy of the growing hip. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 33 条
[1]   AN APPROACH FOR TIME-DEPENDENT BONE MODELING AND REMODELING - APPLICATION - A PRELIMINARY REMODELING SIMULATION [J].
BEAUPRE, GS ;
ORR, TE ;
CARTER, DR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (05) :662-670
[2]   AN APPROACH FOR TIME-DEPENDENT BONE MODELING AND REMODELING - THEORETICAL DEVELOPMENT [J].
BEAUPRE, GS ;
ORR, TE ;
CARTER, DR .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (05) :651-661
[3]   Hip joint contact forces during stumbling [J].
Bergmann, G ;
Graichen, F ;
Rohlmann, A .
LANGENBECKS ARCHIVES OF SURGERY, 2004, 389 (01) :53-59
[4]  
BERGMANN G, 2001, J BIOMECH, V35, P719
[5]   ON THE NUMERICAL TREATMENT OF BONE AS AN ANISOTROPIC MATERIAL [J].
BESDO, D ;
HANDEL, M .
BIOMEDIZINISCHE TECHNIK, 1994, 39 (11) :293-298
[6]   Anatomical and biomechanical investigations of the iliotibial tract [J].
Birnbaum, K ;
Siebert, CH ;
Pandorf, T ;
Schopphoff, E ;
Prescher, A ;
Niethard, FU .
SURGICAL AND RADIOLOGIC ANATOMY, 2004, 26 (06) :433-446
[7]   ROLE OF LOADS AND PROSTHESIS MATERIAL PROPERTIES ON THE MECHANICS OF THE PROXIMAL FEMUR AFTER TOTAL HIP-ARTHROPLASTY [J].
CHEAL, EJ ;
SPECTOR, M ;
HAYES, WC .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (03) :405-422
[8]   Symmetrical and asymmetrical hip rotation and its relationship to hip rotator muscle strength [J].
Cibulka, Michael T. ;
Strube, Michael J. ;
Meier, Damon ;
Selsor, Michelle ;
Wheatley, Christopher ;
Wilson, Nathan G. ;
Irrgang, James J. .
CLINICAL BIOMECHANICS, 2010, 25 (01) :56-62
[9]  
Colgan D., 1994, Strain, V30, P47, DOI 10.1111/j.1475-1305.1994.tb00918.x
[10]   Finite element modelling of the vibrational behaviour of the human femur using CT-based individualized geometrical and material properties [J].
Couteau, B ;
Hobatho, MC ;
Darmana, R ;
Brignola, JC ;
Arlaud, JY .
JOURNAL OF BIOMECHANICS, 1998, 31 (04) :383-386