An ultrasound beamforming method using 1.5-bit ADCs for portable ultrasound scanners

被引:0
|
作者
Kim, JJ [1 ]
Song, TK [1 ]
机构
[1] Sogang Univ, Ctr Med Solut Res, Seoul, South Korea
来源
2004 IEEE Ultrasonics Symposium, Vols 1-3 | 2004年
关键词
beamforming; dither; quantization;
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In this paper, a novel 1.5-bit beamforming algorithm and its architecture for ultra small ultrasound scanners is presented, in which the received RF signals are quantized into 3 levels, -1, 0, +1 and the 1.5-bit samples from all active elements are aggregated taking into account dynamic focusing delays. It is obvious that the 1.5-bit quantizer is greatly simpler than conventional multi-bit ADCs. Since reducing one bit in quantization reduces the SQNR by 6dB, however, the 1.5-bit beamforming method will suffer from low SNR problems. To improve the SNR of the 1.5-bit beamformer, a high sampling rate and a simple dithering technique are used. We verified experimentally that the dithering technique can improve the SQNR by about 12 dB. The experimental results with in-vivo data show that a 64 channel 1.5-bit beamformer provides 7.5 MHz linear array images that might be acceptable for some point-of-care applications when the sample rate is 80 MHz.
引用
收藏
页码:1722 / 1724
页数:3
相关论文
共 50 条
  • [1] A practical integrated 1.5-bit MDAC for pipeline ADCs
    Hu, Rongbin
    Hu, Jingqiang
    Zhang, Xiaoying
    Liu, Kun
    2014 XXXITH URSI GENERAL ASSEMBLY AND SCIENTIFIC SYMPOSIUM (URSI GASS), 2014,
  • [2] A statistical offset calibration technique for 1.5-bit/cycle SAR ADCs
    Li, Dengquan
    Liu, Maliang
    Liu, Shubin
    Liang, Yuhua
    Ding, Ruixue
    MICROELECTRONICS JOURNAL, 2021, 114
  • [3] A capacitor mismatch- and nonlinearity-insensitive 1.5-bit residue stage for pipelined ADCs
    Saberi, Mehdi
    Lotfi, Reza
    2007 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONICS, CIRCUITS AND SYSTEMS, VOLS 1-4, 2007, : 677 - 680
  • [4] A Vector Flow Imaging Method for Portable Ultrasound Using Synthetic Aperture Sequential Beamforming
    Di Ianni, Tommaso
    Hoyos, Carlos Armando Villagomez
    Ewertsen, Caroline
    Kjeldsen, Thomas Kim
    Mosegaard, Jesper
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (11) : 1655 - 1665
  • [5] A quantitative comparison of four current portable ultrasound bladder scanners
    Small, D. R.
    Watson, A.
    McConnachie, A.
    JOURNAL OF CLINICAL UROLOGY, 2008, 1 (01) : 35 - 40
  • [6] Portable Ultrasound Through Compressive Beamforming With Improved Contrast
    Mitrovic, Jovan
    La Pietra, Lynn
    Ignjatovic, Zeljko
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [7] A 1.5-bit/stage Pipeline ADC with FFT-based Calibration Method
    Liang, Ming-Chun
    Hsieh, Cheng-Han
    Lee, Shuenn-Yuh
    2013 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2013, : 2042 - 2045
  • [8] Improving harmonic imaging by a novel beamforming process for ultrasound medical scanners
    Trucco, A
    Bertora, F
    2005 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), VOLS 1-5, 2005, : 3509 - 3512
  • [9] Low-Complexity Compressive Beamforming for Portable Ultrasound Imaging
    George, Swetha Susan
    Mitrovic, Jovan
    Anand, Ajay
    Ignjatovic, Zeljko
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [10] EVALUATING THE EFFECT OF BIT RATE ON THE QUALITY OF PORTABLE ULTRASOUND VIDEO
    Gray, Marissa
    Morchel, Herman
    Hazelwood, Vikki