Determination of lanthanide and actinide elements by energy dispersive x-ray fluorescence spectrometry applying DLLME preconcentration and dried spot

被引:7
|
作者
Sa, Ivero P. [1 ,2 ]
Almeida, Ohana N. [1 ]
Lima, Daniel De C. [1 ,3 ]
da Silva, Erik G. P. [1 ,3 ]
Santos, Luana N. [1 ]
Luzardo, Francisco H. M. [1 ]
Velasco, Fermin G. [1 ]
Gonzalez, Mario H. [4 ]
Amorim, Fabio A. C. [1 ,3 ]
机构
[1] State Univ Santa Cruz UESC, Dept Exact & Technol Sci, Jorge Amado Highway Km 16, BR-45662900 Ilheus, BA, Brazil
[2] Univ Fed Sao Carlos, Dept Chem, Grp Appl Instrumental Anal, BR-13560270 Sao Carlos, SP, Brazil
[3] Univ Fed Bahia, Natl Inst Energy & Environm Sci & Technol, BR-40170115 Salvador, BA, Brazil
[4] Paulista State Univ UNESP, Dept Chem & Environm Sci, IBILICE, POB 136, BR-15054000 Sao Jose Do Rio Preto, SP, Brazil
关键词
X-ray fluorescence spectrometry; Actinides; Lanthanides; Liquid phase microextraction; Dried spot; Multivariate optimization; Water analysis; RARE-EARTH-ELEMENTS; PLASMA-MASS SPECTROMETRY; LIQUID-LIQUID MICROEXTRACTION; ORGANIC DROP MICROEXTRACTION; HEAVY-METAL IONS; ULTRATRACE DETERMINATION; ANALYTICAL-CHEMISTRY; MATRIX ELIMINATION; WATER SAMPLES; ICP-MS;
D O I
10.1016/j.sab.2021.106253
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
This work describes an analytical procedure to determination of trace amount of lanthanide and actinide chemistry elements (LAEs) in water samples by energy dispersive x-ray fluorescence spectrometry (EDXRF) with the prepare of the samples using simultaneous preconcentration procedure based on the dispersive liquid-liquid microextraction (DLLME). Critical study of the analytical procedure occurred the following way: ions of Eu, Er, Ho, Th, U and Yb presents in 5.0 mL of aqueous sample have been complexed with 2-(5-bromo-2-pyridylazo)-5(diethylamino)-phenol (Br-PADAP) in a mixture contained solvents (disperser and extractant). After centrifugation, 30 mu L of the sedimented organic phase has been removed and deposited on membrane disk and submitted to EDXRF analysis. The optimization step was performed by: i) screening factor with mixture design for the disperser solvent (acetone, acetonitrile and ethanol) and extractant solvent (carbon tetrachloride, trichlorethylene and 1,2-dichloroethane); ii) Box-Behnken design for the independents variables: pH, Br-PADAP concentration, volume of disperser solvent and volume of extractant solvent. The optimized conditions were: 500 mu L of disperser solvent (ethanol), 60 mu L extractant solvent (carbon tetrachloride and trichlorethylene, 1: 1 ratio), BrPADAP 1.8 x 10-5 mol L-1 and pH 8.0. In these conditions, the procedure allows the determination of Eu, Ho, Er, Yb, Th and U with quantification limits of 10.5; 8.6; 4.3; 7.0; 6.6 and 1.1 mu g L-1, respectively; preconcentration factor between 18 and 74, and precision (RSD%) below that 6%. Salting out effect, presence of other ions, and additions/recoveries of analytes in real samples was verified and the recovery values were between of 90 to 107%. Analytical method has been applied in waters samples and groundwater from uranium mining region.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] Determination of 12 elements in coal ash by X-ray fluorescence spectrometry
    Song Yi
    Guo Fen
    Gu Song-hai
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2008, 28 (06) : 1430 - 1434
  • [12] Determination of 22 Elements in Herb Tea by X-Ray Fluorescence Spectrometry
    Li Dan
    Ge Liang-quan
    Wang Guang-xi
    Lai Wan-chang
    Zhai Juan
    Chen Lu
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2015, 35 (07) : 2043 - 2048
  • [13] ELECTRODEPOSITION AS A PRECONCENTRATION AND SAMPLE PREPARATION TECHNIQUE FOR TRACE SELENIUM AND TELLURIUM DETERMINATION BY X-RAY FLUORESCENCE SPECTROMETRY
    Li, Qiang
    Zheng, Hongtao
    Zhu, Zhenli
    Tang, Zhiyong
    ANALYTICAL LETTERS, 2014, 47 (05) : 843 - 854
  • [14] Preconcentration of Zn, Cu, and Ni Ions from Coffee Infusions via 8-Hydroxyquinoline Complexes on Graphene Prior to Energy Dispersive X-ray Fluorescence Spectrometry Determination
    Pytlakowska, Katarzyna
    APPLIED SPECTROSCOPY, 2016, 70 (11) : 1891 - 1899
  • [15] Determination of trace amounts of Pb, Cd, Ni and Co by wavelength-dispersive X-ray fluorescence spectrometry after preconcentration with dithizone functionalized graphene
    Zheng, Hongtao
    Jia, Bingtao
    Zhu, Zhenli
    Tang, Zhiyong
    Hu, Shenghong
    ANALYTICAL METHODS, 2014, 6 (21) : 8569 - 8576
  • [16] Determination of major elements by wavelength-dispersive X-ray fluorescence spectrometry and trace elements by inductively coupled plasma mass spectrometry in igneous rocks from the same fused sample (110 mg)
    Amosova, Alena A.
    Panteeva, Svetlana V.
    Chubarov, Victor M.
    Finkelshtein, Alexandr L.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2016, 122 : 62 - 68
  • [17] Use of fiberglass support in the application of dried-spot technique with dispersion liquid-liquid microextraction for the determination of Co, Cr, Cu, Ni and Pb by Energy Dispersive X-Ray Fluorescence Spectrometry
    de Almeida, Ohana Nadine
    Martinez Luzardo, Francisco Heriberto
    Carqueija Amorim, Fabio Alan
    Velasco, Fermin Garcia
    Gonzalez, Luis Nieto
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 150 : 92 - 98
  • [18] Graphene-Based Preconcentration System Prior to Energy Dispersive X-Ray Fluorescence Spectrometric Determination of Co, Ni, and Cu Ions in Wine Samples
    Pytlakowska, Katarzyna
    FOOD ANALYTICAL METHODS, 2016, 9 (08) : 2270 - 2279
  • [19] Determination of high Zn and Pb concentrations in polluted soils using energy-dispersive x-ray fluorescence spectrometry
    Sitko, R
    Zawisza, B
    Jurczyk, J
    Buhl, F
    Zielonka, U
    POLISH JOURNAL OF ENVIRONMENTAL STUDIES, 2004, 13 (01): : 91 - 96
  • [20] A simplified analysis of dimethylarsinic acid by wavelength dispersive X-ray fluorescence spectrometry combined with a strong cation exchange disk
    An, Jinsung
    Kim, Ki-Hyun
    Kim, Joo-Ae
    Jung, Hyeyeon
    Yoon, Hye-On
    Seo, Jungju
    JOURNAL OF HAZARDOUS MATERIALS, 2013, 260 : 24 - 31