A multi-region algorithm for markerless beam's-eye view lung tumor tracking

被引:72
作者
Rottmann, J. [1 ,2 ,3 ]
Aristophanous, M. [1 ,2 ]
Chen, A. [1 ,2 ]
Court, L. [1 ,2 ]
Berbeco, R. [1 ,2 ]
机构
[1] Brigham & Womens Hosp, Dana Farber Canc Inst, Dept Radiat Oncol, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] German Canc Res Ctr, Heidelberg, Germany
关键词
STEREOTACTIC BODY RADIOTHERAPY; IMPLANTED FIDUCIAL MARKERS; CANCER RADIOTHERAPY; GATED RADIOTHERAPY; RESPIRATORY MOTION; RADIATION-THERAPY; FEASIBILITY; MANAGEMENT; LOCATION; IMAGES;
D O I
10.1088/0031-9155/55/18/021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Methods that allow online lung tumor tracking during radiotherapy are desirable for a variety of applications that have the potential to vastly improve treatment accuracy, dose conformity and sparing of healthy tissue. Several publications have proposed the use of an on-board kV x-ray imager to assess the tumor location during treatment. However, there is some concern that this strategy may expose the patient to a significant amount of additional dose over the course of a typical radiotherapy treatment. In this paper we present an algorithm that utilizes the on-board portal imager of the treatment machine to track lung tumors. This does not expose the patient to additional dose, but is somewhat more challenging as the quality of portal images is inferior when compared to kV x-ray images. To quantify the performance of the proposed algorithm we retrospectively applied it to portal image sequences retrieved from a dynamic chest phantom study and an SBRT treatment performed at our institution. The results were compared to manual tracking by an expert. For the phantom data the tracking error was found to be smaller than 1 mm and for the patient data smaller than 2 mm, which was in the same range as the uncertainty of the gold standard.
引用
收藏
页码:5585 / 5598
页数:14
相关论文
共 36 条
[1]   Computerized method for estimation of the location of a lung tumor on EPID cine images without implanted markers in stereotactic body radiotherapy [J].
Arimura, H. ;
Egashira, Y. ;
Shioyama, Y. ;
Nakamura, K. ;
Yoshidome, S. ;
Anai, S. ;
Nomoto, S. ;
Honda, H. ;
Toyofuku, F. ;
Higashida, Y. ;
Onizuka, Y. ;
Terashima, H. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (03) :665-677
[2]   Assessment of Pancreatic Hardness-Surgeon versus Durometer [J].
Belyaev, Orlin ;
Herden, Heinz ;
Meier, Juris J. ;
Muller, Christophe A. ;
Seelig, Matthias H. ;
Herzog, Torsten ;
Tannapfel, Andrea ;
Schmidt, Wolfgang E. ;
Uhl, Waldemar .
JOURNAL OF SURGICAL RESEARCH, 2010, 158 (01) :53-60
[3]   Towards fluoroscopic respiratory gating for lung tumours without radiopaque markers [J].
Berbeco, RI ;
Mostafavi, H ;
Sharp, GC ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (19) :4481-4490
[4]   Residual motion of lung tumours in gated radiotherapy with external respiratory surrogates [J].
Berbeco, RI ;
Nishioka, S ;
Shirato, H ;
Chen, GTY ;
Jiang, SB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (16) :3655-3667
[5]   Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors [J].
Berbeco, RI ;
Jiang, SB ;
Sharp, GC ;
Chen, GTY ;
Mostafavi, H ;
Shirato, H .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (02) :243-255
[6]   A novel method for estimating SBRT delivered dose with beam's-eye-view images [J].
Berbeco, Ross I. ;
Hacker, Fred ;
Zatwarnicki, Chris ;
Park, Sang-June ;
Ionascu, Dan ;
O'Farrell, Desmond ;
Mamon, Harvey J. .
MEDICAL PHYSICS, 2008, 35 (07) :3225-3231
[7]   Clinical feasibility of using an epid in cine mode for image-guided verification of stereotactic body radiotherapy [J].
Berbeco, Ross I. ;
Hacker, Fred ;
Ionascu, Dan ;
Mamon, Harvey J. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01) :258-266
[8]   MAJOR STIMULUS DIMENSIONS DETERMINING DETECTION OF SIMULATED BREAST-LESIONS [J].
BLOOM, HS ;
CRISWELL, EL ;
PENNYPACKER, HS ;
CATANIA, AC ;
ADAMS, CK .
PERCEPTION & PSYCHOPHYSICS, 1982, 32 (03) :251-260
[9]   Fluoroscopic gating without implanted fiducial markers for lung cancer radiotherapy based on support vector machines [J].
Cui, Ying ;
Dy, Jennifer G. ;
Alexander, Brian ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (16) :N315-N327
[10]   Multiple template-based fluoroscopic tracking of lung tumor mass without implanted fiducial markers [J].
Cui, Ying ;
Dy, Jennifer G. ;
Sharp, Gregory C. ;
Alexander, Brian ;
Jiang, Steve B. .
PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (20) :6229-6242