Conversion from dose-length product to effective dose in computed tomography venography of the lower extremities

被引:3
|
作者
Inoue, Yusuke [1 ]
Yonekura, Yuka [1 ]
Nagahara, Kazunori [2 ]
Uehara, Ayuka [2 ]
Ikuma, Hideki [2 ]
机构
[1] Kitasato Univ, Dept Diagnost Radiol, Sch Med, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa, Japan
[2] Kitasato Univ Hosp, Dept Radiol, Minami Ku, 1-15-1 Kitasato, Sagamihara, Kanagawa, Japan
关键词
computed tomography; radiation dose; effective dose; dose-length product; DEEP-VEIN THROMBOSIS; CT VENOGRAPHY; ITERATIVE RECONSTRUCTION; PULMONARY-EMBOLISM; RADIATION; MODULATION;
D O I
10.1088/1361-6498/ac49d6
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
For radiation dose assessment of computed tomography (CT), effective dose (ED) is often estimated by multiplying the dose-length product (DLP), provided automatically by the CT scanner, by a conversion factor. We investigated such conversion in CT venography of the lower extremities performed in conjunction with CT pulmonary angiography. The study subjects consisted of eight groups imaged using different scanners and different imaging conditions (five and three groups for the GE and Siemens scanners, respectively). Each group included ten men and ten women. The scan range was divided into four anatomical regions (trunk, proximal thigh, knee and distal leg), and DLP was calculated for each region (regional DLP). Regional DLP was multiplied by a conversion factor for the respective region, to convert it to ED. The sum of the ED values for the four regions was obtained as standard ED. Additionally, the sum of the four regional DLP values, an approximate of the scanner-derived DLP, was multiplied by the conversion factor for the trunk (0.015 mSv mGy cm(-1)), as a simplified method to obtain ED. When using the simplified method, ED was overestimated by 32.3%-70.2% and 56.5%-66.2% for the GE and Siemens scanners, respectively. The degree of overestimation was positively and closely correlated with the contribution of the middle and distal portions of the lower extremities to total radiation exposure. ED/DLP averaged within each group, corresponding to the conversion factor, was 0.0089-0.0114 and 0.0091-0.0096 mSv mGy cm(-1) for the GE and Siemens scanners, respectively. In CT venography of the lower extremities, ED is greatly overestimated by multiplying the scanner-derived DLP by the conversion factor for the trunk. The degree of overestimation varies widely depending on the imaging conditions. It is recommended to divide the scan range and calculate ED as a sum of regional ED values.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Dose-Length Product to Effective Dose Conversion Factors for Common Computed Tomography Examinations Based on Canadian Clinical Experience
    Elbakri, Idris A.
    Kirkpatrick, Kin D. C.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (01): : 15 - 17
  • [2] Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography
    Trattner, Sigal
    Halliburton, Sandra
    Thompson, Carla M.
    Xu, Yanping
    Chelliah, Anjali
    Jambawalikar, Sachin R.
    Peng, Boyu
    Peters, M. Robert
    Jacobs, Jill E.
    Ghesani, Munir
    Jang, James J.
    Al-Khalidi, Hussein
    Einstein, Andrew J.
    JACC-CARDIOVASCULAR IMAGING, 2018, 11 (01) : 64 - 74
  • [3] Factors affecting dose-length product of computed tomography component in whole-body positron emission tomography/computed tomography
    Inoue, Yusuke
    Takahashi, Keita
    Miyatake, Hiroki
    Nagahara, Kazunori
    Iwasaki, Rie
    JOURNAL OF RADIOLOGICAL PROTECTION, 2022, 42 (02)
  • [4] Estimation of effective dose using the dose length product in chest computed tomography procedures
    Mpumelelo, N.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (04): : 979 - 986
  • [5] Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose
    Trattner, Sigal
    Chelliah, Anjali
    Prinsen, Peter
    Ruzal-Shapiro, Carrie B.
    Xu, Yanping
    Jambawalikar, Sachin
    Amurao, Maxwell
    Einstein, Andrew J.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2017, 208 (03) : 585 - 594
  • [6] Survey of computed tomography techniques and absorbed dose in Italian hospitals: a comparison between two methods to estimate the dose-length product and the effective dose and to verify fulfilment of the diagnostic reference levels
    Origgi, D
    Vigorito, S
    Villa, G
    Bellomi, M
    Tosi, G
    EUROPEAN RADIOLOGY, 2006, 16 (01) : 227 - 237
  • [7] Computed Tomography Dose in Paediatric Care: Simple Dose Estimation Using Dose Length Product Conversion Coefficients
    Tap, Nor Hanani Mohd
    Sidek, Mohamed Ariff Jaafar
    Ridzwan, Siti Farizwana Mohd
    Selvarajah, S. Elavarasi
    Zaki, Faizah Mohd
    Hamid, Hamzaini Abdul
    MALAYSIAN JOURNAL OF MEDICAL SCIENCES, 2018, 25 (04): : 82 - 91
  • [8] Conversion from dose length product to effective dose for the CT component of whole-body PET/CT
    Inoue, Yusuke
    Ohkubo, Yu
    Nagahara, Kazunori
    Uehara, Ayuka
    Takano, Makoto
    ANNALS OF NUCLEAR MEDICINE, 2022, 36 (04) : 411 - 419
  • [9] Lung Cancer Screening CT Sex-Specific Conversion Factors to Estimate Effective Radiation Dose From Dose-Length Product
    Cohen, Stuart L.
    Wang, Jason J.
    Chan, Nicholas
    O'Connell, William
    Shah, Rakesh
    Sanelli, Pina
    Raoof, Suhail
    CHEST, 2019, 156 (06) : 1214 - 1222
  • [10] A survey of computed tomography dose index and dose length product level in usual computed tomography protocol
    Aliasgharzadeh, Akbar
    Mihandoost, Ehsan
    Mohseni, Mehran
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2018, 14 (03) : 549 - 552