Correlations for calculating heat transfer of hydrogen pool boiling

被引:33
作者
Wang, Lei [1 ]
Li, Yanzhong [1 ,2 ]
Zhang, Feini [3 ]
Xie, Fushou [1 ]
Ma, Yuan [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Refrigerating & Cryogen Engn, Xian 710049, Peoples R China
[2] State Key Lab Technol Space Cryogen Propellants, Beijing 100028, Peoples R China
[3] Univ Illinois, Mech Sci & Engn, Urbana, IL 61801 USA
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Liquid hydrogen; Heat transfer; Critical heat flux; Pool boiling; Empirical correlation; HORIZONTAL FLAT-PLATE; LIQUID-HYDROGEN;
D O I
10.1016/j.ijhydene.2016.06.254
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Understanding the heat transfer characteristics of hydrogen pool boiling as well as constructing reliable correlations to guide the boiling heat transfer analysis is of significance to the applications of liquid hydrogen (LH2). In the present paper, the available hydrogen experimental data in literature are summarized and analyzed. Based on these data, several existing correlations aiming at different boiling regimes are evaluated or modified in order to realize the quantitative analysis of hydrogen boiling heat transfer. After sufficient comparison studies, several improved correlations for nucleate boiling, critical heat flux (CHF) and minimum heat flux (MHF) are proposed. Moreover, a complete set of correlations for hydrogen boiling heat transfer are summarized and subsequently a predicted hydrogen boiling curve is constructed. The results show that heat flux in the nucleate boiling regime is approximately a function of Delta T-2.5. For the calculation of hydrogen film boiling, Breen & Westwater correlation seems to be appropriate for revealing the heat transfer characteristics no matter what heater geometry is used. For the hydrogen boiling under 0.1 MPa condition, heat fluxes at onset of nucleate boiling (ONB), CHF and MHF are in the order of 10 W/m(2), 10(5) W/m(2) and 10(3) W/m(2), respectively, and the corresponding wall superheats are approximately 0.1 K, 3 K and 4 K. In addition, pressure effect on hydrogen boiling heat transfer is investigated, and it shows pressure has a significant influence on MHF while a little effect on the heat fluxes in liquid natural convection and film boiling regimes. CHF of hydrogen increases with the increase of system pressure firstly and then decreased with further pressure increase. The maximum of CHF locates at about P/P-c = 0.35. Generally, the present study is beneficial to understand the boiling heat transfer characteristics of hydrogen, and the summarized correlations could provide researchers with reliable mathematical tools to conduct the boiling heat transfer analysis of hydrogen systems. (C) 2016 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:17118 / 17131
页数:14
相关论文
共 41 条
[1]   Studies of the large-scale sea transportation of liquid hydrogen [J].
Abe, A ;
Nakamura, M ;
Sato, I ;
Uetani, H ;
Fujitani, T .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1998, 23 (02) :115-121
[2]  
[Anonymous], 1964, J HEAT TRANS-T ASME
[3]  
[Anonymous], 1963, ADV CRYOGEN ENG
[4]  
BAUMEISTER KJ, 1967, D4035 NASA TN
[5]  
Berenson P.J., 1961, J. Heat Transf., V83, P351, DOI [10.1115/1.3682280, DOI 10.1115/1.3682280]
[6]   HEAT-TRANSFER IN CRYOGENIC LIQUIDS UNDER PRESSURE [J].
BEWILOGUA, L ;
KNONER, R ;
VINZELBERG, H .
CRYOGENICS, 1975, 15 (03) :121-125
[7]  
Breen B.P., 1962, Chemical Engineering Progress, V58, P67
[8]  
Brentari E.G., 1965, NBS317
[9]  
Bromley LA, 1949, AECD2295
[10]  
Carey V.P., 2008, LIQUID VAPOR PHASE C, VSecond