Determination of birefringence and absolute optic axis orientation using polarization-sensitive optical coherence tomography with PM fibers

被引:27
作者
Zhang, J [1 ]
Guo, SG
Jung, WG
Nelson, JS
Chen, ZP
机构
[1] Univ Calif Irvine, Beckman Laser Inst, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Ctr Biomed Engn, Irvine, CA 92612 USA
关键词
D O I
10.1364/OE.11.003262
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A novel polarization-sensitive optical coherence tomography (PS-OCT) system was developed using polarization maintaining ( PM) optical fibers and fiber coupler to measure birefringence properties of samples. Polarization distortion due to PM fibers and coupler can be calibrated with different polarization states during two consecutive A-scans. By processing the analytical interference fringe signals derived from two orthogonal polarization detection channels, the system can be used to measure phase retardation and optic axis orientation. Standard wave plates with different orientation and retardation were used as samples to test the system and calibrating method. We have also applied this system to image biological sample such as beef tendon. (C) 2003 Optical Society of America.
引用
收藏
页码:3262 / 3270
页数:9
相关论文
共 13 条
[1]  
Brosseau C., 1998, FUNDAMENTALS POLARIZ
[2]   In vivo depth-resolved birefringence measurements of the human retinal nerve fiber layer by polarization-sensitive optical coherence tomography [J].
Cense, B ;
Chen, TC ;
Park, BH ;
Pierce, MC ;
de Boer, JF .
OPTICS LETTERS, 2002, 27 (18) :1610-1612
[3]   Phase-sensitive frequency-multiplexed optical low-coherence reflectometery [J].
Davé, DP ;
Akkin, T ;
Milner, TE ;
Rylander, HG .
OPTICS COMMUNICATIONS, 2001, 193 (1-6) :39-43
[4]   Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography [J].
deBoer, JF ;
Milner, TE ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (12) :934-936
[5]   Birefringence characterization of biological tissue by use of optical coherence tomography [J].
Everett, MJ ;
Schoenenberger, K ;
Colston, BW ;
Da Silva, LB .
OPTICS LETTERS, 1998, 23 (03) :228-230
[6]   POLARIZATION-SENSITIVE LOW-COHERENCE REFLECTOMETER FOR BIREFRINGENCE CHARACTERIZATION AND RANGING [J].
HEE, MR ;
HUANG, D ;
SWANSON, EA ;
FUJIMOTO, JG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 1992, 9 (06) :903-908
[7]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[8]   Optical-fiber-based Mueller optical coherence tomography [J].
Jiao, SL ;
Yu, WR ;
Stoica, G ;
Wang, LHV .
OPTICS LETTERS, 2003, 28 (14) :1206-1208
[9]   Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography [J].
Jiao, SL ;
Wang, LHV .
OPTICS LETTERS, 2002, 27 (02) :101-103
[10]   In vivo burn depth determination by high-speed fiber-based polarization sensitive optical coherence tomography [J].
Park, BH ;
Saxer, C ;
Srinivas, SM ;
Nelson, JS ;
de Boer, JF .
JOURNAL OF BIOMEDICAL OPTICS, 2001, 6 (04) :474-479