Improved Reduction of the Tibiofibular Syndesmosis With TightRope Compared With Screw Fixation: Results of a Randomized Controlled Study

被引:55
作者
Sanders, David [1 ,8 ]
Schneider, Prism [2 ,3 ]
Taylor, Michel [1 ,8 ]
Tieszer, Christina [1 ,8 ]
Lawendy, Abdel-Rahman [1 ,8 ]
Duffy, Paul [3 ]
Buckley, Rick [3 ]
Korley, Robert [3 ]
Martin, C. Ryan [3 ]
Carcary, Kimberly [3 ]
McKercher, Ross [3 ]
Yee, Stephanie [3 ]
Harrison, Tanja [3 ]
Schultz, Leah [3 ]
Akbari, Aftab [3 ]
Papp, Steven [4 ]
Gofton, Wade [4 ]
Liew, Allan [4 ]
Lalonde, Karl [4 ]
Foxall, Julia [4 ]
Harris, Nicole [4 ]
Champagne, Philippe-Hugo [5 ]
Balg, Frederic [5 ]
Deshaies, Annie [5 ]
LaRue, Bernard [5 ]
Patenaude, Nicolas [5 ]
Joncas, Jean-Francois [5 ]
Vezina, Francois [5 ]
Ricard, Stephanie [5 ]
Magalhaes, Marc-Andre [5 ]
Svotelis, Amy [5 ]
Lebel, Karina [5 ]
Bedard, Sonia [5 ]
Raynauld, Catherine [5 ]
Apostle, Kelly [6 ]
Viskontas, Darius [6 ]
Stone, Trevor [6 ]
Moola, Farhad [6 ]
Perey, Bertrand [6 ]
Boyer, Dory [6 ]
Lemke, Michael [6 ]
Zomar, Mauri [6 ]
Moon, Karyn [6 ]
Moon, Raely [6 ]
Leighton, Ross [7 ]
Coles, Chad [7 ]
Dunbar, Michael [7 ]
Glazebrook, Mark [7 ]
Coady, Cathy [7 ]
Trenholm, Andrew [7 ]
机构
[1] Victoria Hosp, London Hlth Sci Ctr, Dept Orthoped Surg, London, ON, Canada
[2] Foothills Med Ctr, Dept Orthoped Surg, Calgary, AB, Canada
[3] Foothills Med Ctr, Orthoped Surg, 3134 Hosp Dr, Calgary, AB T2N 5A1, Canada
[4] Ottawa Hosp, Orthoped Surg, Civ Campus,1053 Carling Ave, Ottawa, ON K1Y 4E9, Canada
[5] CHUS, Orthoped Surg, 3001,12e Ave N, Sherbrooke, PQ J1H 5N4, Canada
[6] Royal Columbian Hosp, Fraser Hlth Author, Orthoped Surg, 330 East Columbia St, New Westminster, BC V3L 3W7, Canada
[7] Queen Elizabeth 2 Hlth Sci Ctr, Orthoped Surg, STE 4875 Halifax Infirm Site,1796 Summers St, Halifax, NS B3H 3A7, Canada
[8] Victoria Hosp, London Hlth Sci Ctr, Orthoped Surg, 800 Commissioners Rd E, London, ON N6A 4G5, Canada
[9] Peter Lougheed Ctr, Orthoped Surg, 3500 26 Ave, Calgary, AB T1Y 6J4, Canada
[10] South Hlth Campus, Orthoped Surg, 4448 Front St SE, Calgary, AB T3M 1M4, Canada
[11] St Michaels Hosp, Orthoped Surg, 55 Queen St E, Toronto, ON M5C 1R6, Canada
[12] Hamilton Hlth Sci Ctr, Orthoped Surg, 293 Wellington St N, Hamilton, ON L8L 8E7, Canada
[13] Sunnybrook Hlth Sci Ctr, Orthoped Surg, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
关键词
Tibiofibular syndesmosis; TightRope; reduction; functional outcomes; CT scan; SUTURE-BUTTON; ANKLE; CONSTRUCT; INJURY; FOOT; MALREDUCTION; RELIABILITY; VALIDITY; OUTCOMES; EUROQOL;
D O I
10.1097/BOT.0000000000001559
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To compare the rate of malreduction after high fibular fractures associated with syndesmosis injury treated with open reduction and internal fixation, with either 2 screws or 1 knotless TightRope device. Design: Prospective randomized controlled multicenter trial. Setting: Eleven academic and community hospitals including Level 1 and Level 2 trauma centers across Canada. Patients/Participants: One hundred three patients with OTA/AO 44-C injuries with demonstrated radiographic syndesmosis diastasis or instability after malleolar bony fixation were followed for 12 months after treatment. Methods: Open reduction of the syndesmosis was performed in all cases. Fixation was randomized to either TightRope (1 knotless TightRope, group T) or screw fixation (two 3.5-mm cortical positional screws placed across 3 cortices, group S). Surgical techniques and rehabilitation were standardized. All surgeons were trained or experienced in the use of the TightRope device. Follow-up was performed at 2 and 6 weeks, 3, 6, and 12 months. Main Outcome Measure: Rate of malreduction based on bilateral ankle computed tomography scan results at 3 months after fixation. Secondary outcome measures included adverse events, reoperation, and validated functional outcomes including the EQ-5D, the Olerud-Molander Ankle Score, the Foot and Ankle Disability Index, and the Work Productivity Activity Impairment Questionnaire. The estimated sample size required to detect a difference in reduction rate was 72 patients, but the estimated sample size required to detect a difference in functional outcome scores was 240 patients, suggesting the study was adequately powered for radiographic results only. Results: Overall, the rate of malreduction using screw fixation was 39% compared with 15% using TightRope fixation (P = 0.028, chi(2)). Analysis of computed tomography results was performed using a 2-mm translation or 10-degree rotation threshold for malreduction and included fibular translation (anterior, posterior); syndesmosis distance (anterior, posterior, and mid); medial compression; and rotation (fibular and articular). Patients in group T had greater anterior translation (5.4 +/- 1.8 mm) compared with the contralateral limb (4.3 +/- 1.3 mm, P < 0.01) or group S (4.6 +/- 1.5 mm, P = 0.05). Group T syndesmoses also had greater diastasis compared with control limb (4.1 +/- 1.3 vs. 3.3 +/- 1.4 mm, P < 0.01) and less fibular medialization compared with group S (1.04 +/- 1.8 vs. 0.3 +/- 1.8 mm, P = 0.05). Functional outcome measures demonstrated significant improvements over time, but no differences between fixation groups. Foot and Ankle Disability Index scores at each time interval were 44 +/- 22 (T) versus 45 +/- 24 (S) (6 weeks), 76 +/- 14 versus 73 +/- 17 (3 months), 89 +/- 10 versus 86 +/- 13 (6 months), and 93 +/- 9 versus 90 +/- 14 (12 months) (all P > 0.2). The reoperation rate was higher in the screw group compared with TightRope (30% vs. 4%, P = 0.02) with the difference driven by the rate of implant removal. Conclusions: Based on our results, the TightRope device seems to compare favorably with two, 3.5-mm, 3-cortex screw fixation for syndesmosis injuries.
引用
收藏
页码:531 / 537
页数:7
相关论文
共 50 条
  • [41] Is unilateral pedicle screw fixation as effective as bilateral pedicle screw fixation in transforaminal lumbar interbody fusion: a meta-analysis of randomized controlled trials
    Xu, Lian
    Lin, Xu
    Wu, Chao
    Tan, Lun
    EUROPEAN SPINE JOURNAL, 2023, 32 (02) : 700 - 711
  • [42] Syndesmosis fixation in supination-external rotation ankle fractures. Long-Term results of a prospective randomised study
    Lehtola, Ristomatti
    Leskela, Hannu-Ville
    Flinkkila, Tapio E.
    Pakarinen, Harri J.
    Niinimaki, Jaakko L.
    Ohtonen, Pasi P.
    Kortekangas, Tero H.
    FOOT AND ANKLE SURGERY, 2022, 28 (02) : 229 - 234
  • [43] Screw fixation for syndesmotic injury is stronger and provides more contact area of the joint surface than TightRope®: A biomechanical study
    Graeff, Pascal
    Alanazi, Sulaiman
    Alazzawi, Sulaiman
    Weber-Spickschen, Sanjay
    Krettek, Christian
    Dratzidis, Antonios
    Fleischer-Lueck, Benjamin
    Hawi, Nael
    Liodakis, Emmanouil
    TECHNOLOGY AND HEALTH CARE, 2020, 28 (05) : 533 - 539
  • [44] Cannulated screw fixation and plate fixation for displaced intraarticular calcaneus fracture: A meta-analysis of randomized controlled trials
    Fan, Baoyou
    Zhou, Xianhu
    Wei, Zhijian
    Ren, Yiming
    Lin, Wei
    Hao, Yan
    Shi, Guidong
    Feng, Shiqing
    INTERNATIONAL JOURNAL OF SURGERY, 2016, 34 : 64 - 72
  • [45] Surgical management of low grade isthmic spondylolisthesis; a randomized controlled study of the surgical fixation with and without reduction
    Audat, Ziad M.
    Darwish, Fayeq T.
    Al Barbarawi, Moh'd M.
    Obaidat, Moatasem M.
    Haddad, Walid H.
    Bashaireh, Khaldoon M.
    Al-Aboosy, Ihsan A.
    SCOLIOSIS AND SPINAL DISORDERS, 2011, 6
  • [46] Randomized trial comparing suture button with single 3.5 mm syndesmotic screw for ankle syndesmosis injury: similar results at 2 years
    Raeder, Benedikte Wendt
    Stake, Ingrid Kvello
    Madsen, Jan Erik
    Frihagen, Frede
    Jacobsen, Silje Berild
    Andersen, Mette Renate
    Figved, Wender
    ACTA ORTHOPAEDICA, 2020, 91 (06) : 770 - 775
  • [47] Can Reliability of the Chinese Medicine Diagnostic Process Be Improved? Results of a Prospective Randomized Controlled Trial
    Schnyer, Rosa N.
    McKnight, Patrick
    Conboy, Lisa A.
    Jacobson, Eric
    Ledegza, Anna T.
    Quilty, Mary T.
    Davis, Roger B.
    Wayne, Peter M.
    JOURNAL OF ALTERNATIVE AND COMPLEMENTARY MEDICINE, 2019, 25 (11) : 1103 - 1108
  • [48] Running barefoot leads to lower running stability compared to shod running - results from a randomized controlled study
    Hollander, Karsten
    Hamacher, Daniel
    Zech, Astrid
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [49] Volar Locking Plates Versus External Fixation and Adjuvant Pin Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study
    Williksen, John H.
    Frihagen, Frede
    Hellund, Johan C.
    Kvernmo, Hebe D.
    Husby, Torstein
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2013, 38A (08): : 1469 - 1476
  • [50] Knotless Anchor Fixation for Transosseous Meniscal Root Repair Using Suture Tape Is Inferior Compared With Button or Screw Fixation: A Biomechanical Study
    Robinson, James R.
    Hernandez, Bruno Agostinho
    Taylor, Clare
    Gill, Harinderjit S.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2020, 8 (04)