共 50 条
Improved Reduction of the Tibiofibular Syndesmosis With TightRope Compared With Screw Fixation: Results of a Randomized Controlled Study
被引:55
作者:
Sanders, David
[1
,8
]
Schneider, Prism
[2
,3
]
Taylor, Michel
[1
,8
]
Tieszer, Christina
[1
,8
]
Lawendy, Abdel-Rahman
[1
,8
]
Duffy, Paul
[3
]
Buckley, Rick
[3
]
Korley, Robert
[3
]
Martin, C. Ryan
[3
]
Carcary, Kimberly
[3
]
McKercher, Ross
[3
]
Yee, Stephanie
[3
]
Harrison, Tanja
[3
]
Schultz, Leah
[3
]
Akbari, Aftab
[3
]
Papp, Steven
[4
]
Gofton, Wade
[4
]
Liew, Allan
[4
]
Lalonde, Karl
[4
]
Foxall, Julia
[4
]
Harris, Nicole
[4
]
Champagne, Philippe-Hugo
[5
]
Balg, Frederic
[5
]
Deshaies, Annie
[5
]
LaRue, Bernard
[5
]
Patenaude, Nicolas
[5
]
Joncas, Jean-Francois
[5
]
Vezina, Francois
[5
]
Ricard, Stephanie
[5
]
Magalhaes, Marc-Andre
[5
]
Svotelis, Amy
[5
]
Lebel, Karina
[5
]
Bedard, Sonia
[5
]
Raynauld, Catherine
[5
]
Apostle, Kelly
[6
]
Viskontas, Darius
[6
]
Stone, Trevor
[6
]
Moola, Farhad
[6
]
Perey, Bertrand
[6
]
Boyer, Dory
[6
]
Lemke, Michael
[6
]
Zomar, Mauri
[6
]
Moon, Karyn
[6
]
Moon, Raely
[6
]
Leighton, Ross
[7
]
Coles, Chad
[7
]
Dunbar, Michael
[7
]
Glazebrook, Mark
[7
]
Coady, Cathy
[7
]
Trenholm, Andrew
[7
]
机构:
[1] Victoria Hosp, London Hlth Sci Ctr, Dept Orthoped Surg, London, ON, Canada
[2] Foothills Med Ctr, Dept Orthoped Surg, Calgary, AB, Canada
[3] Foothills Med Ctr, Orthoped Surg, 3134 Hosp Dr, Calgary, AB T2N 5A1, Canada
[4] Ottawa Hosp, Orthoped Surg, Civ Campus,1053 Carling Ave, Ottawa, ON K1Y 4E9, Canada
[5] CHUS, Orthoped Surg, 3001,12e Ave N, Sherbrooke, PQ J1H 5N4, Canada
[6] Royal Columbian Hosp, Fraser Hlth Author, Orthoped Surg, 330 East Columbia St, New Westminster, BC V3L 3W7, Canada
[7] Queen Elizabeth 2 Hlth Sci Ctr, Orthoped Surg, STE 4875 Halifax Infirm Site,1796 Summers St, Halifax, NS B3H 3A7, Canada
[8] Victoria Hosp, London Hlth Sci Ctr, Orthoped Surg, 800 Commissioners Rd E, London, ON N6A 4G5, Canada
[9] Peter Lougheed Ctr, Orthoped Surg, 3500 26 Ave, Calgary, AB T1Y 6J4, Canada
[10] South Hlth Campus, Orthoped Surg, 4448 Front St SE, Calgary, AB T3M 1M4, Canada
[11] St Michaels Hosp, Orthoped Surg, 55 Queen St E, Toronto, ON M5C 1R6, Canada
[12] Hamilton Hlth Sci Ctr, Orthoped Surg, 293 Wellington St N, Hamilton, ON L8L 8E7, Canada
[13] Sunnybrook Hlth Sci Ctr, Orthoped Surg, 2075 Bayview Ave, Toronto, ON M4N 3M5, Canada
关键词:
Tibiofibular syndesmosis;
TightRope;
reduction;
functional outcomes;
CT scan;
SUTURE-BUTTON;
ANKLE;
CONSTRUCT;
INJURY;
FOOT;
MALREDUCTION;
RELIABILITY;
VALIDITY;
OUTCOMES;
EUROQOL;
D O I:
10.1097/BOT.0000000000001559
中图分类号:
R826.8 [整形外科学];
R782.2 [口腔颌面部整形外科学];
R726.2 [小儿整形外科学];
R62 [整形外科学(修复外科学)];
学科分类号:
摘要:
Objective: To compare the rate of malreduction after high fibular fractures associated with syndesmosis injury treated with open reduction and internal fixation, with either 2 screws or 1 knotless TightRope device. Design: Prospective randomized controlled multicenter trial. Setting: Eleven academic and community hospitals including Level 1 and Level 2 trauma centers across Canada. Patients/Participants: One hundred three patients with OTA/AO 44-C injuries with demonstrated radiographic syndesmosis diastasis or instability after malleolar bony fixation were followed for 12 months after treatment. Methods: Open reduction of the syndesmosis was performed in all cases. Fixation was randomized to either TightRope (1 knotless TightRope, group T) or screw fixation (two 3.5-mm cortical positional screws placed across 3 cortices, group S). Surgical techniques and rehabilitation were standardized. All surgeons were trained or experienced in the use of the TightRope device. Follow-up was performed at 2 and 6 weeks, 3, 6, and 12 months. Main Outcome Measure: Rate of malreduction based on bilateral ankle computed tomography scan results at 3 months after fixation. Secondary outcome measures included adverse events, reoperation, and validated functional outcomes including the EQ-5D, the Olerud-Molander Ankle Score, the Foot and Ankle Disability Index, and the Work Productivity Activity Impairment Questionnaire. The estimated sample size required to detect a difference in reduction rate was 72 patients, but the estimated sample size required to detect a difference in functional outcome scores was 240 patients, suggesting the study was adequately powered for radiographic results only. Results: Overall, the rate of malreduction using screw fixation was 39% compared with 15% using TightRope fixation (P = 0.028, chi(2)). Analysis of computed tomography results was performed using a 2-mm translation or 10-degree rotation threshold for malreduction and included fibular translation (anterior, posterior); syndesmosis distance (anterior, posterior, and mid); medial compression; and rotation (fibular and articular). Patients in group T had greater anterior translation (5.4 +/- 1.8 mm) compared with the contralateral limb (4.3 +/- 1.3 mm, P < 0.01) or group S (4.6 +/- 1.5 mm, P = 0.05). Group T syndesmoses also had greater diastasis compared with control limb (4.1 +/- 1.3 vs. 3.3 +/- 1.4 mm, P < 0.01) and less fibular medialization compared with group S (1.04 +/- 1.8 vs. 0.3 +/- 1.8 mm, P = 0.05). Functional outcome measures demonstrated significant improvements over time, but no differences between fixation groups. Foot and Ankle Disability Index scores at each time interval were 44 +/- 22 (T) versus 45 +/- 24 (S) (6 weeks), 76 +/- 14 versus 73 +/- 17 (3 months), 89 +/- 10 versus 86 +/- 13 (6 months), and 93 +/- 9 versus 90 +/- 14 (12 months) (all P > 0.2). The reoperation rate was higher in the screw group compared with TightRope (30% vs. 4%, P = 0.02) with the difference driven by the rate of implant removal. Conclusions: Based on our results, the TightRope device seems to compare favorably with two, 3.5-mm, 3-cortex screw fixation for syndesmosis injuries.