Closed-loop control of bevel-tip needles based on path planning

被引:12
作者
Huo, Benyan [1 ,2 ]
Zhao, Xingang [2 ]
Han, Jianda [2 ]
Xu, Weiliang [3 ]
机构
[1] Zhengzhou Univ, Sch Elect Engn, Zhengzhou, Henan, Peoples R China
[2] Chinese Acad Sci, Shenyang Inst Automat, Shenyang, Liaoning, Peoples R China
[3] Univ Auckland, Auckland, New Zealand
关键词
Medical robotics; Bevel-tip needle; Particle swarm optimization; Path planning; UKF; STEERABLE NEEDLES; FLEXIBLE NEEDLE; SOFT-TISSUE; 3D ENVIRONMENTS; OBSTACLES; INSERTION; MODEL; 3-D;
D O I
10.1017/S0263574718000772
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Bevel-tip needles have the potential to improve paracentetic precision and decrease paracentetic traumas. In order to drive bevel-tip needles precisely with the constrains of path length and path dangerousness, we propose a closed-loop control method that only requires the position of the needle tip and can be easily applied in a clinical setting. The control method is based on the path planning method proposed in this paper. To establish the closed-loop control method, a kinematic model of bevel-tip needles is first presented, and the relationship between the puncture path and controlled variables is established. Second, we transform the path planning method into a multi-objective optimization problem, which takes the path error, path length and path dangerousness into account. Multi-objective particle swarm optimization is employed to solve the optimization problem. Then, a control method based on path planning is presented. The current needle tip attitude is essential to plan an insertion path. We analyze two methods to obtain the tip attitude and compare their effects using both simulations and experiments. In the end, simulations and experiments in phantom tissue are executed and analyzed, the results show that our methods have high accuracy and have the ability to deal with the model parameter uncertainty.
引用
收藏
页码:1857 / 1873
页数:17
相关论文
共 30 条
  • [1] Integrating Deflection Models and Image Feedback for Real-Time Flexible Needle Steering
    Abayazid, Momen
    Roesthuis, Roy J.
    Reilink, Rob
    Misra, Sarthak
    [J]. IEEE TRANSACTIONS ON ROBOTICS, 2013, 29 (02) : 542 - 553
  • [2] 3-D Ultrasound-Guided Robotic Needle Steering in Biological Tissue
    Adebar, Troy K.
    Fletcher, Ashley E.
    Okamura, Allison M.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (12) : 2899 - 2910
  • [3] Alterovitz R, 2005, IEEE INT CONF ROBOT, P1640
  • [4] Alterovitz R., 2005, 2005 IEEE/RSJ International Conference on Intelligent Robots and Systems, P1570
  • [5] Asadian A., 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS 2011), P2551, DOI 10.1109/IROS.2011.6048600
  • [6] Asadian A, 2011, IEEE INT CONF ROBOT, P1896
  • [7] Robot-assisted automatic insertion of steerable needles with closed-loop imaging feedback and intraoperative trajectory replanning
    Bernardes, M. C.
    Adorno, B. V.
    Poignet, P.
    Borges, G. A.
    [J]. MECHATRONICS, 2013, 23 (06) : 630 - 645
  • [8] Screw-based motion planning for bevel-tip flexible needles in 3D environments with obstacles
    Duindam, Vincent
    Alterovitz, Ron
    Sastry, Shankar
    Goldberg, Ken
    [J]. 2008 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-9, 2008, : 2483 - 2488
  • [9] Three-dimensional Motion Planning Algorithms for Steerable Needles Using Inverse Kinematics
    Duindam, Vincent
    Xu, Jijie
    Alterovitz, Ron
    Sastry, Shankar
    Goldberg, Ken
    [J]. INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2010, 29 (07) : 789 - 800
  • [10] Haddadi A, 2011, IEEE ENG MED BIO, P7478, DOI 10.1109/IEMBS.2011.6091845