Assessment of the Correlation Between Implant Stability and Bone Density by Computed Tomography and Resonance Frequency Analysis in Fresh Cadavers

被引:11
作者
Coutant, Jean-Christophe [1 ,2 ]
Seguela, Vincent [3 ]
Hauret, Laurent [4 ]
Caix, Philippe [5 ]
Ella, Bruno [1 ,2 ]
机构
[1] Bordeaux Univ, Lab Anat, F-33405 Talence, France
[2] Bordeaux Univ, Univ Hosp, Dept Odontol & Buccal Hlth, F-33405 Talence, France
[3] Bordeaux Univ, Univ Hosp, Dept Odontol & Buccal Hlth, Hosp Practitioner, F-33405 Talence, France
[4] Bordeaux Univ, Univ Hosp, Dept Odontol & Buccal Hlth, F-33405 Talence, France
[5] Bordeaux Univ, Anat Lab, F-33405 Talence, France
关键词
bone density; implant design; implant primary stability; resonance frequency analysis; CORTICAL BONE; CASE SERIES; THREAD; REHABILITATION;
D O I
10.11607/jomi.2607
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Because of the immediate loading implant process, clinicians must consider implant primary stability issues before initiating surgery. The aim of this study was to assess the correlation between the bone density assessed by computed tomography (CT) images and the primary stability of two implant designs, as determined by resonance frequency analysis (RFA). Materials and Methods: Sixty implants (30 NobelActive, 30 NobelSpeedy [ Nobel Biocare]) were placed in five totally edentulous fresh cadaver maxillae. Before surgery, CT images were analyzed and bone densities measured. Implant primary stabilities (measured in implant stability quotient [ ISQ] units) were determined along the buccolingual and mesiodistal axes by RFA. Correlations were assessed using the Pearson correlation test. Results: Bone densities were similar near NobelActive and NobelSpeedy implants: 434.67 (+/- 220.53) versus 479.87 (+/- 209.05) Hounsfield Units (HU). Bone densities and NobelActive primary stabilities were highly correlated with p = 0.74 (P = .000) and p = 0.78 (P = .000) for the buccolingual and mesiodistal axes, respectively. An association was found between the 350 HU and 50 ISQ values, confirming good primary stabilities. For NobelSpeedy implants, no correlation was found regardless of the axis, with p = -0.07 (P = .72) (buccolingual) and p = -0.10 (P = .59) (mesiodistal). However, poor and good stabilities were observed in the anterior and posterior areas, respectively. Conclusion: This study revealed variations in primary stabilities depending on the implant design. The primary stability of conical implants with a double-lead thread design (NobelActive) seemed bone density-dependent regardless of the area of the maxilla, whereas the primary stability of nearly parallel-wall implants with a classical thread design (NobelSpeedy) seemed dependent on anatomical morphology. These results raise questions about the specific roles of the implant shape and thread design depending on the bone density and alveolar morphology.
引用
收藏
页码:1264 / 1270
页数:7
相关论文
共 26 条
[1]  
Abbo B, 2009, DENT TODAY, V28, P92
[2]  
Abbo B, 2009, DENT TODAY, V28, P90
[3]  
Abbo Bill, 2009, Dent Today, V28, P92
[4]   The effect of thread pattern upon implant osseointegration [J].
Abuhussein, Heba ;
Pagni, Giorgio ;
Rebaudi, Alberto ;
Wang, Hom-Lay .
CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (02) :129-136
[5]  
Agliardi EL, 2009, INT J ORAL MAX IMPL, V24, P887
[6]  
AI-Jetaily S, 2011, SAUDI DENT J, V23, P17
[7]  
Albrektsson T, 1986, INT J ORAL MAXILLOF, V21, P726
[8]  
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[9]   Implant stability and bone density: assessment of correlation in fresh cadavers using conventional and osteotome implant sockets [J].
Cehreli, Murat Cavit ;
Kokat, Ali Murat ;
Comert, Ayhan ;
Akkocaoglu, Murat ;
Tekdemir, Ibrahim ;
Akca, Kwanc .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (10) :1163-1169
[10]   The Effects of Superficial Roughness and Design on the Primary Stability of Dental Implants [J].
dos Santos, Mychelle Vianna ;
Elias, Carlos Nelson ;
Cavalcanti Lima, Jose Henrique .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2011, 13 (03) :215-223