Infected aortic pseudoaneurysm caused by an inferior vena cava filter

被引:2
作者
Fukasawa, Hiroaki [1 ]
Kameyama, Akiko [1 ]
Tsukada, Megumi [1 ]
Imamura, Hiroshi [1 ]
机构
[1] Shinshu Univ, Dept Emergency & Crit Care Med, Sch Med, Matsumoto, Nagano, Japan
关键词
Abscess; aortic replacement surgery; infected aortic pseudoaneurysm; inferior vena cava filter; pulmonary embolism; PENETRATION;
D O I
10.1002/ams2.767
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Inferior vena cava filters are widely used to prevent pulmonary embolism, but they can cause serious complications. Case Presentation: A 45-year-old man with multiple abscesses was transferred to the emergency department from another hospital. Computed tomography revealed bilateral subscapular abscesses, septic pulmonary embolism, and an abdominal aortic pseudoaneurysm with an abscess at the site of the inferior vena cava filter limb inserted 12 years before. After admission to our hospital, surgical drainage of the bilateral subscapular and right wrist joint abscesses was performed; subsequent treatment with ampicillin improved the patient's condition. Inflammation resolved on the 19th hospitalization day, and abdominal aortic replacement surgery was performed. The patient's postoperative course was uneventful. He returned to the previous hospital for rehabilitation after 40 days of hospitalization. Conclusion: Inferior vena cava filters could cause serious complications.
引用
收藏
页数:4
相关论文
共 7 条
[1]   Complications of indwelling retrievable versus permanent inferior vena cava filters [J].
Desai, Tina R. ;
Morcos, Omar C. ;
Lind, Benjamin B. ;
Schindler, Nancy ;
Caprini, Joseph A. ;
Hahn, David ;
Warner, David ;
Gupta, NavYash .
JOURNAL OF VASCULAR SURGERY-VENOUS AND LYMPHATIC DISORDERS, 2014, 2 (02) :166-172
[2]  
Haga Makoto, 2014, Ann Vasc Dis, V7, P413, DOI 10.3400/avd.cr.14-00066
[3]   Caval Penetration by Inferior Vena Cava Filters A Systematic Literature Review of Clinical Significance and Management [J].
Jia, Zhongzhi ;
Wu, Alex ;
Tam, Mathew ;
Spain, James ;
McKinney, J. Mark ;
Wang, Weiping .
CIRCULATION, 2015, 132 (10) :944-952
[4]  
Massara M, 2017, ANN VASC DIS, V10, P423, DOI 10.3400/avd.cr.17-00048
[5]   Endovascular treatment of an abdominal aortic pseudoaneurysm as a late complication of inferior vena cava filter placement [J].
Medina, Carlos R. ;
Indes, Jeffrey ;
Smith, Christopher .
JOURNAL OF VASCULAR SURGERY, 2006, 43 (06) :1278-1282
[6]   Successful management of infected right iliac pseudoaneurysm caused by penetration of migrated inferior vena cava filter: A case report [J].
Weng, Cheng-Xin ;
Wang, Shu-Min ;
Wang, Tie-Hao ;
Zhao, Ji-Chun ;
Yuan, Ding .
WORLD JOURNAL OF CLINICAL CASES, 2021, 9 (30) :9211-9217
[7]   Penetration of Celect Inferior Vena Cava Filters: Retrospective Review of CT Scans in 265 Patients [J].
Zhou, Dayong ;
Moon, Eunice ;
Bullen, Jennifer ;
Sands, Mark ;
Levitin, Abraham ;
Wang, Weiping .