Direct analysis of glass powder samples by radio frequency glow discharge atomic emission spectrometry (rf-GD-AES)

被引:10
|
作者
Pan, XH [1 ]
Marcus, RK [1 ]
机构
[1] Clemson Univ, Dept Chem, Clemson, SC 29634 USA
关键词
radio frequency glow discharge; atomic emission spectrometry; elemental analysis; glass samples;
D O I
10.1007/BF01244747
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is described for the elemental analysis of glass powder samples by rf-GD-AES. Glass powder samples were pressed without binder to form sample disks. A brass sample holder was designed to hold the pellet onto the source and provide a good vacuum seal. Sample preparation conditions and particle sizes are shown to influence spectral characteristics and plasma stabilization times. The discharge operating parameters were optimized based on both raw analyte signal intensity (S) and signal-to-background ratio (S/B), the latter was found more useful in terms of sample-to-sample precision and quantification. A NIST Standard Reference Material (SRM 89 Lead-Barium Glass) was used to evaluate the method. The limits of detection for trace components ranged from 1-10 mu g/g for several elements, depending on the concentrations of the analytes in the SRM. Sample-to-sample reproducibilities were better than 10% RSD and linear calibration curves were obtained using either the Si (I) optical emission as an internal standard or the individual analyte's S/B characteristics.
引用
收藏
页码:239 / 250
页数:12
相关论文
共 26 条
  • [21] High-Sensitivity Determination of K, Ca, Na, and Mg in Salt Mines Samples by Atomic Emission Spectrometry with a Miniaturized Liquid Cathode Glow Discharge
    Yu, Jie
    Zhang, Zhichao
    Lu, Quanfang
    Sun, Duixiong
    Zhu, Shuwen
    Zhang, Xiaomin
    Wang, Xing
    Yang, Wu
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2017, 2017
  • [22] Determination of trace heavy metals in environmental and biological samples by solution cathode glow discharge-atomic emission spectrometry and addition of ionic surfactants for improved sensitivity
    Zhang, Zhen
    Wang, Zheng
    Li, Qing
    Zou, Huijun
    Shi, Ying
    TALANTA, 2014, 119 : 613 - 619
  • [23] Evaluation of open-air type electrolyte-as-cathode glow discharge-atomic emission spectrometry for determination of trace heavy metals in liquid samples
    Mottaleb, MA
    Woo, YA
    Kim, HJ
    MICROCHEMICAL JOURNAL, 2001, 69 (03) : 219 - 230
  • [24] Direct Ultratrace Detection of Lead in a Single Hair Using Portable Electromagnetic Heating Vaporization-Atmospheric Pressure Glow Discharge-Atomic Emission Spectrometry
    Cai, Zhaoqing
    Qian, Ling
    Peng, Xiaoxu
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2021, 93 (44) : 14701 - 14707
  • [25] A liquid chromatography detector based on continuous-flow chemical vapor generation coupled glow discharge atomic emission spectrometry: Determination of organotin compounds in food samples
    Qian, Bing
    Zhao, Jing
    He, Yan
    Peng, Lixu
    Ge, Huilin
    Han, Bingjun
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1608
  • [26] Flow Injection Photochemical Vapor Generation Coupled with Miniaturized Solution-Cathode Glow Discharge Atomic Emission Spectrometry for Determination and Speciation Analysis of Mercury
    Mo, Jiamei
    Li, Qing
    Guo, Xiaohong
    Zhang, Guoxia
    Wang, Zheng
    ANALYTICAL CHEMISTRY, 2017, 89 (19) : 10353 - 10360