摘要
Quantification of myocardial perfusion scintigraphy is frequently performed to assist physicians in detecting coronary artery disease (CAD). Software packages provide automated quantification of perfusion data. We aimed to compare the three commonly used software packages, Emory Cardiac Toolbox (ECT v2 and ECT v3), 4D-MSPECT (4DM v2 and 4DM v4) and Quantitative Perfusion SPECT (QPS v3 and QPS v4). We selected 283 patients who had a myocardial perfusion scintigraphy with (201)Tl followed by coronary angiography within 3 months. Summed stress score (SSS), summed difference score (SDS), total stress defect extent (TDE) and regional stress defect extent values were obtained from programs. A a parts per thousand yen70% stenosis in coronary arteries and their major branches was considered positive for CAD. A subgroup of patients was used to form an institutional normal database for QPS and 4DM. Receiver-operating characteristic (ROC) analysis to detect CAD was performed. Mean SSS +/- SD (vendor) for ECT v3, QPS v4 and 4DM v4 were 9.2 +/- 7.1, 10.1 +/- 6.8 and 5.5 +/- 6.1, respectively. Area under the curve (AUC) values of SSS ROC analysis were 0.738 +/- 0.031 for QPS v3, 0.755 +/- 0.030 for QPS v4, 0.758 +/- 0.030 for ECT v2, 0.778 +/- 0.029 for ECT v3 and 0.771 +/- 0.030 for 4DM v4. The AUC values for TDE were 0.755 +/- 0.030 for QPS v4, 0.769 +/- 0.030 for ECT v3 and 0.775 +/- 0.029 for 4DM v4. The differences were not significant for both SSS and TDE. Differences of AUC between regional stress defect extent values of programs and AUC of SSS between institutional and vendor normal databases were not significant. The diagnostic performances of programs to detect CAD are similar. However, there are differences in the magnitudes of the quantitative values produced by the programs.
引用
收藏
页码:2070 / 2078
页数:9
相关论文
共 23 条
  • [1] TOLERANCE AND SAFETY OF PHARMACOLOGICAL CORONARY VASODILATION WITH ADENOSINE IN ASSOCIATION WITH TL-201 SCINTIGRAPHY IN PATIENTS WITH SUSPECTED CORONARY-ARTERY DISEASE
    ABREU, A
    MAHMARIAN, JJ
    NISHIMURA, S
    BOYCE, TM
    VERANI, MS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) : 730 - 735
  • [2] Operator dependent variability in quantitative analysis of myocardial perfusion images
    Åkesson, L
    Svensson, A
    Edenbrandt, L
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2004, 24 (06) : 374 - 379
  • [3] BRAMBILLA M, 1994, J NUCL MED, V35, P601
  • [4] Interhospital observer agreement in interpretation of exercise myocardial Tc-99m tetrofosmin SPECT studies
    Candell-Riera, J
    Santana-Boado, C
    Bermejo, B
    Armadans, L
    Castell, J
    Casáns, I
    Jurado, JA
    Magriñá, J
    de la Rosa, JAN
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2001, 8 (01) : 49 - 57
  • [5] SAFETY PROFILE OF ADENOSINE STRESS PERFUSION IMAGING - RESULTS FROM THE ADENOSCAN-MULTICENTER-TRIAL-REGISTRY
    CERQUEIRA, MD
    VERANI, MS
    SCHWAIGER, M
    HEO, J
    ISKANDRIAN, AS
    ALAZRAKI, NP
    BEAN, LC
    BELARDINELLI, L
    BELL, M
    BERMAN, DS
    BOTVINICK, EH
    CHEIRIF, J
    HANSEN, CL
    HELLER, GV
    JOHNSTON, DL
    LEPPO, JA
    MADDAHI, J
    PARKER, LS
    MOHIUDDIN, S
    RAICHLEN, JS
    REIS, GJ
    SCHELBERT, HR
    SEALS, AA
    STOLZENBERG, J
    WILLIAMS, KA
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) : 384 - 389
  • [6] The increasing role of quantification in clinical nuclear cardiology: The Emory approach
    Garcia, Ernest V.
    Faber, Tracy L.
    Cooke, C. David
    Folks, Russell D.
    Chen, Ji
    Santana, Cesar
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) : 420 - 432
  • [7] Quantitation in gated perfusion SPECT imaging: The Cedars-Sinai approach
    Germano, Guido
    Kavanagh, Paul B.
    Slomka, Piotr J.
    Van Kriekinge, Serge D.
    Pollard, Geoff
    Berman, Daniel S.
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (04) : 433 - 454
  • [8] Stress myocardial perfusion single-photon emission computed tomography is clinically effective and cost effective in risk stratification of patients with a high likelihood of coronary artery disease (CAD) but no known CAD
    Hachamovitch, R
    Hayes, SW
    Friedman, JD
    Cohen, I
    Berman, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (02) : 200 - 208
  • [9] Exercise myocardial perfusion SPECT in patients without known coronary artery disease: Incremental prognostic value and use in risk stratification
    Hachamovitch, R
    Berman, DS
    Kiat, H
    Cohen, I
    Cabico, JA
    Friedman, J
    Diamond, GA
    [J]. CIRCULATION, 1996, 93 (05) : 905 - 914
  • [10] A METHOD OF COMPARING THE AREAS UNDER RECEIVER OPERATING CHARACTERISTIC CURVES DERIVED FROM THE SAME CASES
    HANLEY, JA
    MCNEIL, BJ
    [J]. RADIOLOGY, 1983, 148 (03) : 839 - 843