Neutron capture autoradiography for a study on boron neutron capture therapy

被引:21
|
作者
Ogura, K
Yamazaki, A
Yanagie, H
Eriguchi, M
Lehmann, EH
Küehne, G
Bayon, G
Maruyama, K
Kobayashi, H
机构
[1] Nihon Univ, Coll Ind Technol, High Technol Res Ctr, Narashino, Chiba 2750005, Japan
[2] Univ Tokyo, Inst Med Sci, Dept Surg, Minato Ku, Tokyo 108, Japan
[3] Paul Scherrer Inst, Dept Spallat Neutron Source, CH-5232 Villigen, Switzerland
[4] CEN Saclay, CEA, SIREN, DRE,SRO, F-91191 Gif Sur Yvette, France
[5] Teikyo Univ, Sch Pharmaceut Sci, Sagamiko, Kanagawa 1990195, Japan
[6] Rikkyo Univ, Inst Atom Energy, Yokosuka, Kanagawa 24001, Japan
关键词
boron neutron capture therapy; neutron capture alpha-autoradiography; CR-39; cold neutron; thermal neutron; PEW etching solution;
D O I
10.1016/S1350-4487(01)00227-X
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
For the study on boron neutron capture therapy, CR-39 plastic track detectors attached with the whole-body sections of tumor bearing mice infused with B-10 were exposed to thermal and cold neutron beams. Neutron capture autoradiographic images obtained by the cold neutron irradiation were extremely superior in quality than that of the thermal neutron beams, which possibly are contaminated by the fast neutron component. The LET distributions of the neutron-induced particles suggested that the fast neutron component was considerably included in the thermal neutron beams used in this study. In addition, the quality of radiographic images obtained by PEW etching is compared with the images on CR-39 etched in a NaOH solution. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:555 / 558
页数:4
相关论文
共 50 条
  • [31] Liposomes containing boronophenylalanine for boron neutron capture therapy
    Perugini, P
    Pavanetto, F
    JOURNAL OF MICROENCAPSULATION, 1998, 15 (04) : 473 - 483
  • [32] Role of gel dosimeters in boron neutron capture therapy
    Khajeali, Azim
    Farajollahi, Ali Reza
    Khodadadi, Roghayeh
    Kasesaz, Yaser
    Khalili, Assef
    APPLIED RADIATION AND ISOTOPES, 2015, 103 : 72 - 81
  • [34] Boron Neutron Capture Therapy for Malignant Brain Tumors
    Miyatake, Shin-Ichi
    Kawabata, Shinji
    Hiramatsu, Ryo
    Kuroiwa, Toshihiko
    Suzuki, Minoru
    Kondo, Natsuko
    Ono, Koji
    NEUROLOGIA MEDICO-CHIRURGICA, 2016, 56 (07) : 361 - 371
  • [35] Boron Neutron Capture Therapy for Newly Diagnosed Glioblastoma
    Kawabata, Shinji
    Miyatake, Shin-Ichi
    Kuroiwa, Toshihiko
    Yokoyama, Kunio
    Doi, Atsushi
    Iida, Kyoko
    Miyata, Shiro
    Nonoguchi, Naosuke
    Michiue, Hiroyuki
    Takahashi, Masatsugu
    Inomata, Taisuke
    Imahori, Yoshio
    Kirihata, Mitsunori
    Sakura, Yoshinori
    Maruhashi, Akira
    Kumada, Hiroaki
    Ono, Koji
    JOURNAL OF RADIATION RESEARCH, 2009, 50 (01) : 51 - 60
  • [36] boron neutron capture therapy for glioblastoma: The delivery dilemma
    Reva, Marina
    Mendes, Maria
    Sousa, Joao Jose
    Pais, Alberto
    Vitorino, Carla
    LIFE SCIENCES, 2025, 364
  • [37] ENHANCEMENT OF THE EPITHERMAL NEUTRON BEAM USED FOR BORON NEUTRON-CAPTURE THERAPY
    LIU, HYB
    BRUGGER, RM
    GREENBERG, DD
    RORER, DC
    HU, JP
    HAUPTMAN, HM
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05): : 1149 - 1156
  • [38] Intratumoral Transforming Boron Nanosensitizers for Amplified Boron Neutron Capture Therapy
    Li, Liping
    Wang, Mixue
    Zhao, Qian
    Bai, Peirong
    Hao, Haotian
    Zhang, Zizhu
    Liu, Tong
    Yang, Yongzhen
    Pu, Kanyi
    Zhang, Ruiping
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2024,
  • [39] Boron neutron capture therapy for glioblastoma: improvement of boron biodistribution by hyaluronidase
    Haselsberger, K
    Radner, H
    Pendl, C
    CANCER LETTERS, 1998, 131 (01) : 109 - 111
  • [40] A critical assessment of boron target compounds for boron neutron capture therapy
    Hawthorne, MF
    Lee, MW
    JOURNAL OF NEURO-ONCOLOGY, 2003, 62 (01) : 33 - 45